105025-1440 ZEXEL 9 432 611 424 BOSCH NOZZLE 9432611424 1050251440 me742290


 

Information nozzle

BOSCH 9 432 611 424 9432611424
ZEXEL 105025-1440 1050251440
MITSUBISHI ME742290 me742290
105025-1440 NOZZLE
Rating:
20
Buy NOZZLE 105025-1440 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105025-1440 
9 432 611 424 
NP-DLLA148SM144 
ME742290  MITSUBISHI
NOZZLE
C 50LC NOZZLE N (DLL-S) N




Information:

Storage Procedure
When a generator is in storage for any length of time, moisture condenses in the windings. Minimize the condensation by use of a dry storage space and space heaters. Refer to step 2 belowIf a brush-type generator (SRCR) is to be in storage for a year or more, lift the brushes off the slip ring to prevent damage to the slip ring by chemical action.After Storage
Test the main stator windings with a megohmmeter in the following situations: 1. Before initial startup of generator set.2. Every 3 months* if generator is operating in a humid environment.3. If generator has not been run under load for 3 months* or more.*This is a guideline only. It may be necessary to megger more frequently if environment is extremely humid, salty or if the last megger test was close to 1 megohm.The megohmmeter test is described in Service Manuals SENR2180 or SENR7968. A reading of 1 meghom or less indicates that the winding has absorbed too much moisture.To Remove Moisture
To remove moisture caused by high humidity, use one of the following methods to make the generator dry:1. Energize space heaters in generator if so equipped.2. Put the generator in an oven at a temperature of not more than 85°C (185°F) for four hours.
If an oven is used for drying, use a forced air type rather than a radiant type. Radiant ovens can cause localized overheating.
3. Space heaters of the same type used in marine applications, can be installed on generators. (See the Parts Book.) These heaters heat the windings to remove moisture and should be connected at all times in high humidity conditions whenever the generator is not running.4. Use a canvas enclosure around the generator and heating lamps to increase the temperature. Make an opening in the top for release of moisture.5. Send a low voltage current through the windings to increase the temperature of the windings. Do not exceed 85°C (185°F).If the megohmmeter test reads under 1 megohm after the drying or if it goes below 1 megohm shortly after drying, contact your Caterpillar dealer. The insulation has deteriorated and should be reconditioned.

Have questions with 105025-1440?





Group cross 105025-1440 ZEXEL

Nissan-Diesel 

9 432 610 659 
NP-DLLA155SM140 
1662096579 
NOZZLE

Hino 

9 432 611 442 
NP-DLLA140SM141 
236402560A 
NOZZLE
9 432 612 633 
NP-DLLA155SM142 
 
NOZZLE

Mitsubishi 

9 432 610 660 
NP-DLLA157SM143 
ME742289 
NOZZLE
105025-1440  
9 432 611 424 
NP-DLLA148SM144 
ME742290 
NOZZLE
9 432 610 870 
NP-DLLA151SM145 
ME742293 
NOZZLE

Isuzu 

9 432 610 788 
NP-DLLA156SM146 
1153112700 
NOZZLE

Hino 

9 432 611 434 
NP-DLLA155SM147 
236402510A 
NOZZLE

Isuzu 

9 432 610 661 
NP-DLLA165SM148 
1153112810 
NOZZLE

Komatsu 

9 432 611 435 
NP-DLLA142SM149 
6152153150 
NOZZLE