Information nozzle set
BOSCH
9 432 610 776
9432610776
ZEXEL
105019-0700
1050190700
MITSUBISHI
ME741636
me741636

Rating:
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$655.66
30 Jan 2019
Parts Expr: Parts Express
NOZZLE - FUEL FOR MITSUBISHI: 1050190700
MITSUBISHI || All Brand new & rebuilt items comes with 1 year warranty. || NOZZLE - FUEL FOR MITSUBISHI: Â FORKLIFT. MB1050190700 MB1050190700 MITSUBISHI 1050190700 MB 1050190700 1050190700 MITSUBISHI1050190700 Â Â Â Â Â Â THIS PART IS ALSO LISTED UNDER THE FOLLOWING PART NUMBERS:
MITSUBISHI || All Brand new & rebuilt items comes with 1 year warranty. || NOZZLE - FUEL FOR MITSUBISHI: Â FORKLIFT. MB1050190700 MB1050190700 MITSUBISHI 1050190700 MB 1050190700 1050190700 MITSUBISHI1050190700 Â Â Â Â Â Â THIS PART IS ALSO LISTED UNDER THE FOLLOWING PART NUMBERS:
Include in #1:
106673-7182
as NOZZLE SET
Cross reference number
Zexel num
Bosch num
Firm num
Name
105019-0700
ME741636 MITSUBISHI
NOZZLE SET
C 53KY NOZZLE KIT NZ-KIT N&NH
C 53KY NOZZLE KIT NZ-KIT N&NH
Information:
Water Pump
Inspection of Water Pump
If the inspection of the impeller and shaft finds abnormal noise or rough rotation, replace the assembly.
Inspection of impeller and shaft rotation conditionThermostat
Disassembly of Thermostat
Inspection of Thermostat
To test the thermostat operation, immerse the thermostat in a container filled with water, and heat the water while measuring the water temperature. Record the temperature at which the valve starts to open and the temperature at which the valve lift becomes 8 mm [0.3 in.] or more. (a) Stir the water in the container to ensure uniform temperature distribution.(b) When installing the thermostat, be sure to check the valve opening temperature indication stamped on the upper face of the thermostat mounting flange.
Inspection of thermostatOverheat Warning Unit (Thermo Switch)
Inspection of Overheat Warning Unit
Immerse the temperature sensor in oil, and measure the resistance while increasing the oil temperature. If the temperature measurement exceeds the standard value significantly, replace the thermo switch.
Since the inspection requires heating of oil to high temperatures, be careful not to get burns or start a fire.
Overheat warning unit
Inspection of Water Pump
If the inspection of the impeller and shaft finds abnormal noise or rough rotation, replace the assembly.
Inspection of impeller and shaft rotation conditionThermostat
Disassembly of Thermostat
Inspection of Thermostat
To test the thermostat operation, immerse the thermostat in a container filled with water, and heat the water while measuring the water temperature. Record the temperature at which the valve starts to open and the temperature at which the valve lift becomes 8 mm [0.3 in.] or more. (a) Stir the water in the container to ensure uniform temperature distribution.(b) When installing the thermostat, be sure to check the valve opening temperature indication stamped on the upper face of the thermostat mounting flange.
Inspection of thermostatOverheat Warning Unit (Thermo Switch)
Inspection of Overheat Warning Unit
Immerse the temperature sensor in oil, and measure the resistance while increasing the oil temperature. If the temperature measurement exceeds the standard value significantly, replace the thermo switch.
Since the inspection requires heating of oil to high temperatures, be careful not to get burns or start a fire.
Overheat warning unit