105015-9950 ZEXEL 9 432 610 521 BOSCH NOZZLE 9432610521 1050159950 35a6100800


 

Information nozzle

BOSCH 9 432 610 521 9432610521
ZEXEL 105015-9950 1050159950
MITSUBISHI-HEAV 35A6100800 35a6100800
105015-9950 NOZZLE
Rating:
26
Buy NOZZLE 105015-9950 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105015-9950 
9 432 610 521 
NP-DLLA158SN995 
35A6100800  MITSUBISHI-HEAV
NOZZLE
C 50LC NOZZLE N (DLL-S) N




Information:

CONFIDENTIAL
TECHNICAL INFORMATION BULLETIN March 27, 2002
Engines 3516 (25Z, 5SJ, 7KM, CMD, 4XF)
3516B (1HZ, 7RN, 5AN, FDN, BDP,
6HN)
Component Code: 1404SUBJECT: Generator Stator Adapter Cracking on 3516 Diesel Generator Set
PROBLEM:
Certain SR4B single bearing generators may develop cracks in the adapter assembly. The generator adapter is the welded assembly, part of the generator stator, consisting of the front adapter ring that bolts to the flywheel housing and the individual support bars welded to this adapter ring. Several different weld failure modes exist for the generator adapter. First, there may be cracks along the top weld leg between the adapter supports and the front adapter ring. Second, there may be cracks at the toe of the welds joining the adapter support bars to the front ring. These cracks appear in the heat-affected zone of the welds and propagate into the front adapter ring of the generator. The third failure mode is radial cracks between the end ring of the generator adapter and the stator housing. This type of crack most likely occurs after the support welds have failed. After the support welds have failed, the cracks at the toe of the support bars propagate into the ring and create a stress riser.
SOLUTION:
Caterpillar is redesigning the current product and is also working on a solution that will address the existing units in the field. At this time, it is NOT recommended to immediately replace cracked generator stators, nor is it recommended to re-weld the cracked adapters as a field repair. Rather, a crack observation and evaluation process should be established for each individual case. It is anticipated that the first recognizable cracks on suspect generators (cracks size of 0.25" and larger) may appear as early as 300 hours. If any of the above-described cracks are found, the servicing dealer should contact Caterpillar Service. The servicing dealer should also assist in periodic inspection of the cracks in an effort to determine the next action.
Contact (if different from sender): Miro Halicek (770) 233-5877 or Marc Sylvester (770) 233-5630.
COPYRIGHT 2002 CATERPILLAR
ALL RIGHTS RESERVED

Have questions with 105015-9950?





Group cross 105015-9950 ZEXEL

Mitsubishi 

9 432 611 398 
NP-DLLA154SN990 
ME731999 
NOZZLE
9 432 610 520 
NP-DLLA155SN991 
3256157900 
NOZZLE

Mitsubishi-Heav 

9 432 610 520 
NP-DLLA155SN991 
3256157900 
NOZZLE

Hino 

9 432 611 415 
NP-DLLA150SN992 
236402250A 
NOZZLE
9 432 611 392 
NP-DLLA150SN993 
236402260A 
NOZZLE
9 432 611 393 
NP-DLLA150SN994 
236402270A 
NOZZLE

Mitsubishi-Heav 

105015-9950  
9 432 610 521 
NP-DLLA158SN995 
35A6100800 
NOZZLE

Mitsubishi 

9 432 611 394 
NP-DLLA157SN996 
ME738446 
NOZZLE

Hino 

9 432 611 395 
NP-DLLA157SN997 
236402240A 
NOZZLE
9 432 610 522 
NP-DLLA150SN998 
236402251A 
NOZZLE
9 432 610 522 
NP-DLLA150SN998 
S236402251 
NOZZLE
9 432 610 523 
NP-DLLA150SN999 
236402261A 
NOZZLE
9 432 610 523 
NP-DLLA150SN999 
S236402261 
NOZZLE
Back to top