Information nozzle
BOSCH
9 432 610 241
9432610241
ZEXEL
105015-3760
1050153760
NISSAN-DIESEL
16620Z5501
16620z5501
Rating:
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$161.89
15 Jan 2024
KR: Adabus
Injector Nozzle 12 Pieces DLLA155S551 DLLA155S529 DLLA155S4820 DLLA155S365N458 DLLA155S334NP96 Diesel Pump Nozzle - (Color: DLLA155S529)
Generic Color: DLLA155S529 || Is customized: No || Material type: Metal || Item length: 8 || Origin: Mainland China
Generic Color: DLLA155S529 || Is customized: No || Material type: Metal || Item length: 8 || Origin: Mainland China
$42.99
17 Mar 2023
0.66[0.30] Pounds
CN: lutong part plant
Diesel Injector Nozzle Tips 105015-3760 DLLA155S334NP96 Fits for NISSAN DIESEL FD6/A496 4pcs/lot
DICSCL PARCS Diesel Injector Nozzle Tips 105015-3760 DLLA155S334NP96 fits for NISSAN DIESEL FD6/A496 4pcs/lot || Material: Made of high quality for longer durability and strength.100% quality inspection to ensure the high quality. Upgraded packaging to avoid damage. || Easy Installation:No further modification to direct replacement. || OEM Part Number:DLLA155S334NP96 || Estimated Time of Delivery from China: 5-10 working days.Customer satisfaction is always our top priority, we are standing by ready to provide you with reliable assistance with any questions you may have
DICSCL PARCS Diesel Injector Nozzle Tips 105015-3760 DLLA155S334NP96 fits for NISSAN DIESEL FD6/A496 4pcs/lot || Material: Made of high quality for longer durability and strength.100% quality inspection to ensure the high quality. Upgraded packaging to avoid damage. || Easy Installation:No further modification to direct replacement. || OEM Part Number:DLLA155S334NP96 || Estimated Time of Delivery from China: 5-10 working days.Customer satisfaction is always our top priority, we are standing by ready to provide you with reliable assistance with any questions you may have
$54.99
17 Mar 2023
0.88[0.40] Pounds
CN: lutong part plant
6Pcs Fuel Injector Nozzles 105015-3760 DLLA155S334NP96 Fits for NISSAN DIESEL FD6
DICSCL PARCS Injector Nozzle Tips 105015-3760 DLLA155S334NP96 fits for NISSAN DIESEL FD6/A496 6pcs/lot || Material: Made of high quality for longer durability and strength.100% quality inspection to ensure the high quality. Upgraded packaging to avoid damage. || Easy Installation:No further modification to direct replacement. || OEM Part Number:DLLA155S334NP96 || Estimated Time of Delivery from China: 5-10 working days.Customer satisfaction is always our top priority, we are standing by ready to provide you with reliable assistance with any questions you may have
DICSCL PARCS Injector Nozzle Tips 105015-3760 DLLA155S334NP96 fits for NISSAN DIESEL FD6/A496 6pcs/lot || Material: Made of high quality for longer durability and strength.100% quality inspection to ensure the high quality. Upgraded packaging to avoid damage. || Easy Installation:No further modification to direct replacement. || OEM Part Number:DLLA155S334NP96 || Estimated Time of Delivery from China: 5-10 working days.Customer satisfaction is always our top priority, we are standing by ready to provide you with reliable assistance with any questions you may have
Cross reference number
Zexel num
Bosch num
Firm num
Name
105015-3760
16620Z5501 NISSAN-DIESEL
NOZZLE
C 50LC NOZZLE N (DLL-S) N
C 50LC NOZZLE N (DLL-S) N
Information:
Caterpillar's Scheduled Oil Sampling (S O S) is the best indicator for determining what is happening inside your engine.S O S is a diagnostic tool used to determine oil performance and component wear rates with a series of tests designed to identify and measure contamination such as soot, sulfur, etc. and degradation such as the presence of fuel, water and antifreeze in a sample of oil.The tests also determine the amount of wear metals present in the oil sample, which is compared to established Caterpillar norms to determine acceptability. To be effective as an indicator, S O S must be performed on a continuing basis. Intermittent sampling will not allow wear rate trend lines to be established.
S O S Sampling Valve (if equipped) Obtain at Every 250 Hour Interval or Oil Change.Obtain S O S samples at regularly scheduled intervals to monitor the condition and maintenance requirements of your engine. Each oil sample should be taken when the oil is warm and well mixed to ensure that the sample is representative of the oil in the engine crankcase.Consult your Caterpillar dealer for complete information and assistance in establishing an S O S program for your engine(s).S O S Analysis
S O S is composed of three basic tests: * Wear Analysis* Chemical and Physical Tests* Oil Condition Analysis Wear analysis is performed with an atomic absorption spectrophotometer to monitor component wear by identifying and measuring concentrations, in parts per million, of wear elements present in the oil. Based on known normal concentration data, maximum limits of wear elements are established. Impending failures can be identified when test results deviate from concentration levels established as acceptable, based on normal wear. Chemical and physical tests detect the presence of water, fuel and glycol (antifreeze) in the oil and determine whether or not their concentrations exceed established maximum limits. Oil condition is evaluated with infrared analysis. This test determines the presence and measures the amount of contaminants such as soot, sulfur products, oxidation, and nitration products in the oil. Infrared analysis can also assist in customizing (reducing, maintaining or extending) oil change intervals for particular conditions and applications.Infrared analysis should always be accompanied by wear element analysis and chemical and physical tests to assure accurate diagnosis. Infrared analysis must be used to determine oil change intervals. S O S must include Infrared (IR) in the analysis.The test results of the oil samples will then be used as a basis for determining the oil change interval for your engine, giving you the ultimate time between oil changes without the risk of engine damage.Refer to Caterpillar pamphlet Scheduled Oil Sampling, form PEDP7105 for imformation and benefits of S O S.
S O S Sampling Valve (if equipped) Obtain at Every 250 Hour Interval or Oil Change.Obtain S O S samples at regularly scheduled intervals to monitor the condition and maintenance requirements of your engine. Each oil sample should be taken when the oil is warm and well mixed to ensure that the sample is representative of the oil in the engine crankcase.Consult your Caterpillar dealer for complete information and assistance in establishing an S O S program for your engine(s).S O S Analysis
S O S is composed of three basic tests: * Wear Analysis* Chemical and Physical Tests* Oil Condition Analysis Wear analysis is performed with an atomic absorption spectrophotometer to monitor component wear by identifying and measuring concentrations, in parts per million, of wear elements present in the oil. Based on known normal concentration data, maximum limits of wear elements are established. Impending failures can be identified when test results deviate from concentration levels established as acceptable, based on normal wear. Chemical and physical tests detect the presence of water, fuel and glycol (antifreeze) in the oil and determine whether or not their concentrations exceed established maximum limits. Oil condition is evaluated with infrared analysis. This test determines the presence and measures the amount of contaminants such as soot, sulfur products, oxidation, and nitration products in the oil. Infrared analysis can also assist in customizing (reducing, maintaining or extending) oil change intervals for particular conditions and applications.Infrared analysis should always be accompanied by wear element analysis and chemical and physical tests to assure accurate diagnosis. Infrared analysis must be used to determine oil change intervals. S O S must include Infrared (IR) in the analysis.The test results of the oil samples will then be used as a basis for determining the oil change interval for your engine, giving you the ultimate time between oil changes without the risk of engine damage.Refer to Caterpillar pamphlet Scheduled Oil Sampling, form PEDP7105 for imformation and benefits of S O S.