Information nameplate
BOSCH
9 461 628 625
9461628625
ZEXEL
146984-6000
1469846000

Rating:
Include in #2:
104741-7450
as NUMBER PLATE
Include in ###:
Cross reference number
Zexel num
Bosch num
Firm num
Name
146984-6000
9 461 628 625
NAMEPLATE
C 11FV NUMBER PLATE parts(VE) Others
C 11FV NUMBER PLATE parts(VE) Others
Information:
7G7889 Alternator
Voltage rating ... 12VPolarity ... Neg GrndRotation ... Either DirectionSpeed for testing (rpm) ... 2600 to 6500Output (cold) ... 28 A @ 14VOutput (cold) ... 62A @ 14VRated output (hot) at max speed ... 60 AField current at rated voltage and 27°C (80°F) ... 7 to 8APositive output terminal torque ... 6.2 to 8.0 N m (55 to 71 lb in)(1) Ground terminal torque ... 1.7 to 2.9 N m (15 to 26 lb in)(2) Shaft nut torque ... 95 to 109 N m (70 to 80 lb ft)Regulator (9G5235-Inside Alternator)
Voltage setting ... No AdjustmentPermissible voltage range ... 13 to 15V3T6352 Alternator
Voltage rating ... 24VPolarity ... Neg GrndRotation ... Either DirectionSpeed for testing (rpm) ... 2600 to 6500Output (cold) ... 15A @ 28VOutput (cold) ... 35A @ 28VRated output (hot) at max speed ... 35AField current at rated voltage and 27°C (80°F) ... 2.5 to 3.2APositive output terminal torque ... 6.2 to 8.0 N m (55 to 71 lb in)(1) Ground terminal torque ... 1.7 to 2.9 N m (15 to 26 lb in)(2) Shaft nut torque ... 95 to 109 N m (70 to 80 lb ft)Regulator (3T6354 - Inside alternator)
Voltage setting ... No AdjustmentPermissible voltage range ... 26 to 30 V 9G6079 & 6T1194 Alternators
Voltage rating ... 12VPolarity ... Neg GrndRotation ... Either DirectionOutput at 2000 rpm (cold) ... 30AOutput at 5000 rpm (cold) ... 57ARated output (hot) ... 61A(1) Torque for stud nut for battery connection ... 2.8 to 4.5 N m (25 to 40 lb in)(2) Torque for pulley nut ... 100 7 N m (75 5 lb ft)Voltage Regulator (3S8828) is internally mounted and is not adjustable.9G6081 & 6T1196 Alternators
Polarity ... Neg GrndRotation ... Either DirectionOutput at 2600 rpm (cold) ... 25AOutput at 7000 rpm (cold) ... 41ARated output (hot) ... 40A(1) Torque for stud nut for battery connection ... 2.8 to 4.5 N m (25 to 40 lb in)(2) Torque for pulley nut ... 100 7 N m (75 5 lb ft)Voltage Regulator (3T6354) is internally mounted and not adjustable.Bosch Alternators
7N9720 Alternator
Voltage rating ... 24VPolarity ... Neg GrndRotation ... Either DirectionSpeed for testing (rpm) ... 4000Output (cold) ... 47AOutput (hot) ... 37AField Current at 28V and 25° C (77°F) ... 1.8A(1) Torque for pulley nut ... 95 to 110 N m (70 to 80 lb ft)(2) Torque for output terminal B+ ... 7.5 to 10 N m (5.5 to 7.0 lb ft)Torque for ground terminal ... 2.1 to 2.8 N m (19 to 25 in lb)Regulator Number ... 9G7567 9W3043 Alternator
Voltage rating ... 24VPolarity ... Neg GrndRotation ... ClockwiseSpeed for testing (rpm) ... 5000Output (cold) ... 40AOutput (hot) ... 52AField current at 28V and 25°C (77°F) ... 2.9A(1) Torque for pulley nut ... 50 5 N m (37 4 lb ft)(2) Torque for output terminal B+ ... 7.8 0.8 N m (70 7 lb in)(3) Torque for field D+ terminal nut ... 1.70 0.25 N m (15 2 lb
Voltage rating ... 12VPolarity ... Neg GrndRotation ... Either DirectionSpeed for testing (rpm) ... 2600 to 6500Output (cold) ... 28 A @ 14VOutput (cold) ... 62A @ 14VRated output (hot) at max speed ... 60 AField current at rated voltage and 27°C (80°F) ... 7 to 8APositive output terminal torque ... 6.2 to 8.0 N m (55 to 71 lb in)(1) Ground terminal torque ... 1.7 to 2.9 N m (15 to 26 lb in)(2) Shaft nut torque ... 95 to 109 N m (70 to 80 lb ft)Regulator (9G5235-Inside Alternator)
Voltage setting ... No AdjustmentPermissible voltage range ... 13 to 15V3T6352 Alternator
Voltage rating ... 24VPolarity ... Neg GrndRotation ... Either DirectionSpeed for testing (rpm) ... 2600 to 6500Output (cold) ... 15A @ 28VOutput (cold) ... 35A @ 28VRated output (hot) at max speed ... 35AField current at rated voltage and 27°C (80°F) ... 2.5 to 3.2APositive output terminal torque ... 6.2 to 8.0 N m (55 to 71 lb in)(1) Ground terminal torque ... 1.7 to 2.9 N m (15 to 26 lb in)(2) Shaft nut torque ... 95 to 109 N m (70 to 80 lb ft)Regulator (3T6354 - Inside alternator)
Voltage setting ... No AdjustmentPermissible voltage range ... 26 to 30 V 9G6079 & 6T1194 Alternators
Voltage rating ... 12VPolarity ... Neg GrndRotation ... Either DirectionOutput at 2000 rpm (cold) ... 30AOutput at 5000 rpm (cold) ... 57ARated output (hot) ... 61A(1) Torque for stud nut for battery connection ... 2.8 to 4.5 N m (25 to 40 lb in)(2) Torque for pulley nut ... 100 7 N m (75 5 lb ft)Voltage Regulator (3S8828) is internally mounted and is not adjustable.9G6081 & 6T1196 Alternators
Polarity ... Neg GrndRotation ... Either DirectionOutput at 2600 rpm (cold) ... 25AOutput at 7000 rpm (cold) ... 41ARated output (hot) ... 40A(1) Torque for stud nut for battery connection ... 2.8 to 4.5 N m (25 to 40 lb in)(2) Torque for pulley nut ... 100 7 N m (75 5 lb ft)Voltage Regulator (3T6354) is internally mounted and not adjustable.Bosch Alternators
7N9720 Alternator
Voltage rating ... 24VPolarity ... Neg GrndRotation ... Either DirectionSpeed for testing (rpm) ... 4000Output (cold) ... 47AOutput (hot) ... 37AField Current at 28V and 25° C (77°F) ... 1.8A(1) Torque for pulley nut ... 95 to 110 N m (70 to 80 lb ft)(2) Torque for output terminal B+ ... 7.5 to 10 N m (5.5 to 7.0 lb ft)Torque for ground terminal ... 2.1 to 2.8 N m (19 to 25 in lb)Regulator Number ... 9G7567 9W3043 Alternator
Voltage rating ... 24VPolarity ... Neg GrndRotation ... ClockwiseSpeed for testing (rpm) ... 5000Output (cold) ... 40AOutput (hot) ... 52AField current at 28V and 25°C (77°F) ... 2.9A(1) Torque for pulley nut ... 50 5 N m (37 4 lb ft)(2) Torque for output terminal B+ ... 7.8 0.8 N m (70 7 lb in)(3) Torque for field D+ terminal nut ... 1.70 0.25 N m (15 2 lb
Have questions with 146984-6000?
Group cross 146984-6000 ZEXEL
146984-6000
9 461 628 625
NAMEPLATE