Information locking washer
BOSCH
9 411 610 061
9411610061
ZEXEL
139306-0100
1393060100
ISUZU
8941227250
8941227250

Rating:
Include in ###:
Cross reference number
Zexel num
Bosch num
Firm num
Name
139306-0100
9 411 610 061
8941227250 ISUZU
LOCKING WASHER
C 90HY SPRING WASHER Standard parts Others
C 90HY SPRING WASHER Standard parts Others
139306-0100
9 411 610 061
ME741022 MITSUBISHI
LOCKING WASHER
C 90HY SPRING WASHER Standard parts Others
C 90HY SPRING WASHER Standard parts Others
139306-0100
9 411 610 061
19279W3400 NISSAN
LOCKING WASHER
C 90HY SPRING WASHER Standard parts Others
C 90HY SPRING WASHER Standard parts Others
139306-0100
9 411 610 061
19279W3400 NISSAN-DIESEL
LOCKING WASHER
C 90HY SPRING WASHER Standard parts Others
C 90HY SPRING WASHER Standard parts Others
139306-0100
9 411 610 061
1926380G00 NISSAN-DIESEL
LOCKING WASHER
A C 90HY SPRING WASHER Standard parts Others
A C 90HY SPRING WASHER Standard parts Others
139306-0100
9 411 610 061
RF7113TM4 MAZDA
LOCKING WASHER
C 90HY SPRING WASHER Standard parts Others
C 90HY SPRING WASHER Standard parts Others
Information:
Test Procedure
System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.The green "RUN" LED is illuminated. The processor is in the "RUN" mode.The red "FLT" LED is flashing during operation. The processor detects a major fault. The fault is in the processor expansion chassis or the fault is in the memory.The amber "FORCE" LED is illuminated. The forces are enabled.The amber "FORCE" LED is not illuminated. No forces are present or no forces are enabled.
Illustration 1 g00563544
Diagram of the LED indicators
Illustration 2 g00562937
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 2.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Clear the fault.
Place the switch in the PROG position.
Place the switch in the RUN position.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 3.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Refer to Maintenance Procedure, "Processor - Replace".
System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.The green "RUN" LED is illuminated. The processor is in the "RUN" mode.The red "FLT" LED is flashing during operation. The processor detects a major fault. The fault is in the processor expansion chassis or the fault is in the memory.The amber "FORCE" LED is illuminated. The forces are enabled.The amber "FORCE" LED is not illuminated. No forces are present or no forces are enabled.
Illustration 1 g00563544
Diagram of the LED indicators
Illustration 2 g00562937
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 2.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Clear the fault.
Place the switch in the PROG position.
Place the switch in the RUN position.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 3.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Refer to Maintenance Procedure, "Processor - Replace".
Have questions with 139306-0100?
Group cross 139306-0100 ZEXEL
Isuzu
139306-0100
9 411 610 061
8941227250
LOCKING WASHER
Mitsubishi
139306-0100
9 411 610 061
ME741022
LOCKING WASHER
Nissan
139306-0100
9 411 610 061
19279W3400
LOCKING WASHER
Nissan-Diesel
139306-0100
9 411 610 061
19279W3400
LOCKING WASHER
139306-0100
9 411 610 061
1926380G00
LOCKING WASHER
Mazda
139306-0100
9 411 610 061
RF7113TM4
LOCKING WASHER