108922-3065 ZEXEL 9 400 611 930 BOSCH INJECTION-PUMP ASSEMBLY 9400611930 1089223065 220401153a


 

Information injection-pump assembly

BOSCH 9 400 611 930 9400611930
ZEXEL 108922-3065 1089223065
HINO 220401153A 220401153a
108922-3065 INJECTION-PUMP ASSEMBLY
Rating:
56
Buy INJECTION-PUMP ASSEMBLY 108922-3065 zexel genuine, new aftermarket engine parts with delivery

Service parts 108922-3065 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108092-0161
3. GOVERNOR 105952-2330
4. SUPPLY PUMP 105237-4670
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-2240
7. COUPLING PLATE 156643-0721
9. _
10. NOZZLE AND HOLDER ASSY 105101-8240
11. Nozzle and Holder 23600-3040A
12. Open Pre:MPa(Kqf/cm2) 14.7{150}/21.6{220}
13. NOZZLE-HOLDER 105030-3730
14. NOZZLE
15. NOZZLE SET 105019-0880

Include in #1:

108922-3065 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
108922-3065 
108922-3066 
9 400 611 930 
220401153A  HINO
INJECTION-PUMP ASSEMBLY
V26C-B * K 14CR TICS HD-TI10F TICS




Information:

Procedure
Note: Prior to performing the analysis with the APC, be sure to read and understand all the interferences listed in the "Interferences Inherent In the Fuel Sample" section of this document. Ensure that all precautions have been taken to minimize the affect of skewed results due to improper sampling, handling, or preparation.
Obtain the fuel sample to be analyzed in an appropriate sample bottle as described in the "Fuel Sample Preparation" section. Manually or mechanically shake the sample vigorously for 30 seconds. When manually shaking a sample, ensure thorough mixing of the sample by turning the bottle so that the lid is facing downward. Shake by moving the wrist and/or forearm up and down as rapidly as is comfortable for the 30 seconds.Note: Degassing samples can be accomplished with either the use of an ultrasonic bath or with the use of a vacuum pump.
Immediately degas the sample, by partially opening the lid to the bottle and placing the sample upright in the degassing unit. Perform only one of the degassing methods. An ultrasonic bath is the best method for degassing a sample. An ultrasonic bath takes the least amount of time minimizing the impact of particle settling.Note: The purpose of partially unscrewing or opening the lid is to promote quick degassing of the sample. Air bubbles to remaining near the surface of the sample following the degassing process are acceptable.
Illustration 5 g01741117
If an ultrasonic bath is unavailable, an alternative method of degassing the sample is with the use of a 1U-5718 Oil Sampling Vacuum Pump. Ensure the 1U-5718 Oil Sampling Vacuum Pump is clean before beginning the degas process.Note: Rubber is to be placed over the hole of the tubing for the pump to develop and hold the required vacuum.
With the sample to be analyzed in the sample bottle, thread the bottle into the bottom of the 1U-5718 Oil Sampling Vacuum Group. Operate the pump to create a vacuum. Maintain the vacuum until all air bubbles have risen to the surface of the sample and dissipated.
If an ultrasonic bath or a vacuum pump is not available, the sample can degas naturally. Degas the sample by setting the sample on a flat surface and leaving the sample undisturbed. If the APC performs a flushing cycle, let the sample sit for 15 seconds. If the APC does not perform a flushing cycle, such as the 293-8413 HYDAC Contamination Monitor Group or the 383-4255 HYDAC Contamination Monitor Group, let the sample sit for 30 seconds. Proceed to the "Sample Processing" section.Sample Processing
Remove the lid from the sample bottle. Immediately begin the processing of the sample on the APC that has been prepared according to the "Fuel Sample Preparation" section.Note: If more than 45 seconds elapse after the shaking of the sample, the procedure shall be restarted with shaking of the sample in "Fuel Sample Preparation" section. Shaking the sample ensures that suspended particles do not settle to the bottom of the sample, causing inaccurate particle count results.
Obtain the particle count results

Have questions with 108922-3065?





Group cross 108922-3065 ZEXEL

Hino 

 
220401150A 
INJECTION-PUMP ASSEMBLY
YJ45
 
220401151A 
INJECTION-PUMP ASSEMBLY
YJ45
F 019 Z20 390 
 
INJECTION-PUMP ASSEMBLY

Hino 

F 01G 09U 0HT 
220401152A 
INJECTION-PUMP ASSEMBLY
V26C-B
9 400 611 570 
220401152B 
INJECTION-PUMP ASSEMBLY
V26C-B
108922-3065  

108922-3066 
9 400 611 930 
220401153A 
INJECTION-PUMP ASSEMBLY
V26C-B
F 019 Z20 391 
220401154A 
INJECTION-PUMP ASSEMBLY
V26C-B
Back to top