108822-7230 ZEXEL 9 400 613 026 BOSCH INJECTION-PUMP ASSEMBLY 9400613026 1088227230 me351921


 

Information injection-pump assembly

BOSCH 9 400 613 026 9400613026
ZEXEL 108822-7230 1088227230
MITSUBISHI ME351921 me351921
108822-7230 INJECTION-PUMP ASSEMBLY
Rating:
16
Buy INJECTION-PUMP ASSEMBLY 108822-7230 zexel genuine, new aftermarket engine parts with delivery

Service parts 108822-7230 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108082-3700
3. GOVERNOR 105960-0292
4. SUPPLY PUMP 105237-0300
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-0990
7. COUPLING PLATE
10. NOZZLE AND HOLDER ASSY 105110-7920
11. Nozzle and Holder ME072662
12. Open Pre:MPa(Kqf/cm2) 17.7{180}/24.5{250}
13. NOZZLE-HOLDER 105041-4290
14. NOZZLE
15. NOZZLE SET 105019-2410

Include in #1:

108822-7230 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
108822-7230 
108822-7231 
9 400 613 026 
ME351921  MITSUBISHI
INJECTION-PUMP ASSEMBLY
8M21 * K 14CQ TICS HD-TI8F TICS




Information:

The following topics describe care and maintenance of the electrical system components. These components functioning together produce the energy needed for operating the electrical equipment on the truck and each is dependent upon the other for satisfactory operation. In the event of failure or improper operation, it is essential to check the entire electrical system as a defect in one component can cause damage to another.Many electrical system problems can be traced to loose or corroded connections. Keep connections tight and make sure the wiring insulation is in satisfactory condition. Most of electrical system testing can be performed on the vehicle. (It should be remembered, if a malfunction is found on a vehicle test, the component may need further testing, repair or replacement.) Installations will have electrical components not furnished by Caterpillar. Consult the vehicle manufacturer's manual for maintenance procedures.Check the electrolyte level of each cell and the general condition of the battery. Maintain the electrolyte level to the base of each vent well. The make-up water must be one of the following (in order of preference): 1. Distilled water.2. Odorless, tasteless drinking water.3. Iron free water.4. Any available water.
Never add acid or electrolyte.
CLEANING BATTERY: Mix a weak solution of baking soda and water. Be careful not to get cleaning solution into battery. Apply the solution with a soft bristle brush.
CLEANING BATTERY TERMINALSThoroughly rinse the battery and battery tray with clean water. Apply grease to the battery cable clamps and terminals and to all threads. Testing The Electrolyte Solution: The general condition of a battery can be determined by measuring the specific gravity of the electrolyte solution and adjusting the reading to 80°F (27°C). If the electrolyte level is too low to allow taking a hydrometer reading, add make-up water to the correct level and then charge the battery 2 to 4 hours before taking a reading.
TESTING ELECTROLYTE SOLUTION1. Insert the hydrometer into a cell. Fill the hydrometer barrel while holding it vertically. The float must not drag on the wall of the barrel.2. Read the hydrometer: 1.250 or above - fully charged battery cell1.250-1.225 - full to half charged battery cell1.225-1.150 - half to low charged battery cellBelow 1.150 - dead cell1.000 - water3. Test each cell in the same manner.4. If there is more than .050 (50 gravity points) variation between the highest and lowest reading, the battery may need to be replaced.5. Adjust the readings to 80°F (27°C). a. For every 10F° (5.5C°) the electrolyte temperature is above 80°F (27°C), add .004 (4 gravity points) to the specific gravity readings.b. For every 10F°(5.5C°) the electrolyte temperature is below 80°F (27°C), subtract .004 (4 gravity points) from the specific gravity reading.The corrected reading is of most importance during cold weather when the hydrometer reading is always corrected to a lower specific gravity reading. A low reading signifies the battery has less available power to crank the engine and that booster batteries may be required. Voltage Test (After Load): A load test should be made on a

Have questions with 108822-7230?





Group cross 108822-7230 ZEXEL

9 400 611 975 
 
INJECTION-PUMP ASSEMBLY
8M21
9 400 612 094 
 
INJECTION-PUMP ASSEMBLY
9 400 612 396 
 
INJECTION-PUMP ASSEMBLY
9 400 612 685 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 619 374 
ME165430 
INJECTION-PUMP ASSEMBLY
8M21
 
ME355314 
INJECTION-PUMP ASSEMBLY
8M21
F 019 Z10 299 
ME355585 
INJECTION-PUMP ASSEMBLY
8M21
9 400 612 767 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

F 019 Z20 381 
ME351539 
INJECTION-PUMP ASSEMBLY
8M21
 
 
INJECTION-PUMP ASSEMBLY
8M21
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
9 400 619 375 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

F 019 Z20 382 
ME165200 
INJECTION-PUMP ASSEMBLY
8M21
108822-7230  

108822-7231 
9 400 613 026 
ME351921 
INJECTION-PUMP ASSEMBLY
8M21
9 400 619 631 
ME354919 
INJECTION-PUMP ASSEMBLY
8M21
F 019 Z20 383 
ME355584 
INJECTION-PUMP ASSEMBLY
8M21
9 400 612 966 
ME351917 
INJECTION-PUMP ASSEMBLY
8M21
F 019 Z20 384 
ME354920 
INJECTION-PUMP ASSEMBLY
8M21
9 400 619 376 
ME351918 
INJECTION-PUMP ASSEMBLY
8M21
F 019 Z20 385 
ME354921 
INJECTION-PUMP ASSEMBLY
8M21
9 400 619 377 
ME352417 
INJECTION-PUMP ASSEMBLY
8M21
9 400 619 632 
ME354917 
INJECTION-PUMP ASSEMBLY
8M21
9 400 619 378 
ME353380 
INJECTION-PUMP ASSEMBLY
8M21
9 400 619 633 
ME354918 
INJECTION-PUMP ASSEMBLY
8M21
F 01G 09U 0HE 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 619 379 
ME354037 
INJECTION-PUMP ASSEMBLY
8M21
9 400 619 435 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 619 380 
ME354038 
INJECTION-PUMP ASSEMBLY
8M21
Back to top