108822-7120 ZEXEL 9 400 611 569 BOSCH INJECTION-PUMP ASSEMBLY 9400611569 1088227120 me163890


 

Information injection-pump assembly

BOSCH 9 400 611 569 9400611569
ZEXEL 108822-7120 1088227120
MITSUBISHI ME163890 me163890
108822-7120 INJECTION-PUMP ASSEMBLY
Rating:
66
Buy INJECTION-PUMP ASSEMBLY 108822-7120 zexel genuine, new aftermarket engine parts with delivery

Service parts 108822-7120 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108082-3600
3. GOVERNOR 105923-4210
4. SUPPLY PUMP 105237-5030
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-0990
7. COUPLING PLATE
10. NOZZLE AND HOLDER ASSY 105110-7381
11. Nozzle and Holder ME093732
12. Open Pre:MPa(Kqf/cm2) 17.7{180}/21.6{220}
13. NOZZLE-HOLDER 105041-4120
14. NOZZLE
15. NOZZLE SET 105019-0350

Include in #1:

108822-7120 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
108822-7120 
9 400 611 569 
ME163890  MITSUBISHI
INJECTION-PUMP ASSEMBLY
8M21 K 14CK INJECTION PUMP ASSY TICS HD-TI8M TICS




Information:


Illustration 4 g01341045
(6) Temperature Sensor
(7) Pressure Sensor
Mount the 271-7350 Warning Indicator Module Gp in a place that is easy to view. Ensure that the ambient temperature is below 45 °C (113 °F), and ensure that the Warning Indicator Module is not directly exposed to high pressure steam cleaning, solvents, the battery off gas, or electrical discharge. Note: The LED display panel may be installed in the cab of the vehicle.
Illustration 5 g01341118
(8) LED display panel
(9) ECM Installation for the Wiring Harness
The 274-7578 Monitor Electronic Control Module is provided with a 307-5521 Wire Harness.
Connect the 70 pin AMP to the ECM using a 160-7690 Connector Plug As. Tighten the Connector Screw for the ECM to 6 1 N m (4 0.73 lb ft).
Locate a 12 VDC or 24 VDC power supply that is always available even when the key is turned "OFF".
Connect the power wires from the wiring harness to the power supply. Install a 15 AMP fuse in this circuit. If an additional wire must be spliced, use a 14 gauge wire.
Attach the appropriate connectors to the pressure sensor, the temperature sensor, and the lamp group. Note: The service tool that is used in this installation is Caterpillar Electronic Technician (CAT ET). The service tool connector is a 9 pin Deutsch connector that contains the CDL (Caterpillar Data Link)/ATA, CAN/J1939, and power. A connection from the 274-7578 Monitor Electronic Control Module to the PC requires a Caterpillar Communications adapter, which connects to the PC via a serial port.The service tool (CAT ET) supports the following functions:
Download and review active alarms and logged alarms
Clear active alarms
View the data in real time.
Flash the diagnostic module.
Provide the capability for the user to configure certain parameters.Software Configuration
Refer to Systems Operation, Troubleshooting, Testing and Adjusting, KENR6695 for a description of controllable parameters and operation instructions.Once the 274-7578 Monitor Electronic Control Modulehas power, the 274-7578 Monitor Electronic Control Module will begin monitoring the pressure sensors and the temperature sensors.
Check whether CAT ET is configured with English or Metric units.
Set CAT ET to Metric units if a Metric unit is not already selected. Specifications
Table 3
System Requirements
Requirements for 12VDC or 24VDC System Value Notes
Operating Voltage Minimum +9V Minimum continuous operating voltage without damage to the ECM
Maximum Operating Voltage +32V Maximum continuous operating voltage without damage to the ECM
The voltage is over the maximum voltage that is allowed (two minutes continuous). +80V At 25 °C (77 °F)
Reverse Voltage (one hour) -32V At 85 °C (185 °F)
Power up voltage for the ECM +9V The minimum voltage for the ECM to internally run. Operating the engine at this voltage will cause the damage to the ECM.
The maximum current draw with key switch off 10mA
Maximum current draw with zero engine speed and no loads being driven 500mA
Maximum continuous operating current draw 10A This highly dependent upon the number and type of loads driven by the ECM
Recommended size for the Battery Fuse. 15A
Table 4
Operating Conditions
Thermal Conditions Vibrations Humidity Tolerance Salt Spray Tolerance Moisture Leakage Chemical Splash Immunity Electrostatic Environment
Operating Temperature Range:

Have questions with 108822-7120?





Group cross 108822-7120 ZEXEL

Mitsubishi 

9 400 619 370 
ME163888 
INJECTION-PUMP ASSEMBLY
8M21
9 400 619 371 
ME163889 
INJECTION-PUMP ASSEMBLY
8M21
108822-7120  
9 400 611 569 
ME163890 
INJECTION-PUMP ASSEMBLY
8M21
9 400 611 368 
ME163891 
INJECTION-PUMP ASSEMBLY
8M21
9 400 613 348 
ME163892 
INJECTION-PUMP ASSEMBLY
8M21
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 611 651 
ME095517 
INJECTION-PUMP ASSEMBLY
8DC9T2
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 612 600 
ME095546 
INJECTION-PUMP ASSEMBLY
8DC9T7
9 400 611 490 
 
INJECTION-PUMP ASSEMBLY
8DC11
9 400 619 372 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

F 019 Z20 378 
ME095653 
INJECTION-PUMP ASSEMBLY
8DC11
9 400 611 491 
 
INJECTION-PUMP ASSEMBLY
8M21
9 400 612 684 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

F 019 Z20 379 
ME164627 
INJECTION-PUMP ASSEMBLY
8M21
9 400 612 248 
 
INJECTION-PUMP ASSEMBLY
8M21
9 400 619 373 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

F 019 Z20 380 
ME164955 
INJECTION-PUMP ASSEMBLY
8M21
Back to top