108822-3246 ZEXEL 9 400 611 408 BOSCH INJECTION-PUMP ASSEMBLY 9400611408 1088223246 220401174b


 

Information injection-pump assembly

BOSCH 9 400 611 408 9400611408
ZEXEL 108822-3246 1088223246
HINO 220401174B 220401174b
108822-3246 INJECTION-PUMP ASSEMBLY
Rating:
13
Buy INJECTION-PUMP ASSEMBLY 108822-3246 zexel genuine, new aftermarket engine parts with delivery

Service parts 108822-3246 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108082-3540
3. GOVERNOR 105952-2243
4. SUPPLY PUMP 105237-4610
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-0960
7. COUPLING PLATE
10. NOZZLE AND HOLDER ASSY 105101-8400
11. Nozzle and Holder 23600-3160A
12. Open Pre:MPa(Kqf/cm2) 16.7{170}/23.5{240}
13. NOZZLE-HOLDER 105030-3740
14. NOZZLE
15. NOZZLE SET 105019-2140

Include in #1:

108822-3246 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
108822-3246 
108822-3247 
9 400 611 408 
220401174B  HINO
INJECTION-PUMP ASSEMBLY
F17D-TE * K




Information:


Illustration 74 g02026337 Appendix D
Cleaned Filter Specification
Note: Scope: The following steps determine a properly cleaned Caterpillar filter.Note: This specification applies to filters that were cleaned of ash only. This specification is only valid subsequent to the "Recommended Cleaning Procedure". This specification should not be used to determine if soot filled filters are properly cleaned. All filters must be baked appropriately using the "Recommended Cleaning Procedure" prior to application of this specification.HEALTH AND SAFETY
Wear goggles, gloves, protective clothing, and a National Institute for Occupational Safety and Health (NIOSH) approved P95 or N95 half-face respirator when handling a used Diesel Particulate Filter or Catalytic Converter Muffler. Failure to do so could result in personal injury.
Adhere to all local Health and Safety rules and regulations. Use all the personal protective equipment listed below:
Respirator
Safety shoes
Safety glasses
Latex gloves
Lab coatRESOURCESNecessary equipment:
38 cm (15 inch) long by 0.9 mm (0.04 inch) thick stainless steel probe for "200 cpsi" (Cells/Square inch) filters
Tape measureMETHODEvaluation of a cleaned filter:Note: A filter MUST meet all criteria in this section below to be considered clean.
Inspect both inlet and outlet surfaces for oil/fuel contamination, gouges and/or cracks. No cracks may be visible. Gouges may not be exceed 4.0 mm (0.15 inch) deep.
There must be no filter movement within the filters banding. This movement is defined as the substrate moving past the bent-over flange. The filter must be even or below the bent-over flange.
There must not be any signs of the steel fiber ring coming loose or any mat material (cottony gauze) slipping past the filter. See Illustration 75 below.
The flanges are not damaged beyond repair.
There are no dents deeper than 6.4 mm (0.25 inch) in the outer can of the filter and the outer can is not cracked, torn or otherwise breached.
No more than 20 cells are allowed to be damaged (showing soot) on the outlet face of the filter. Refer to Illustrations 76 and 77.
Inspect the ash depth in the cells using the "Check Cell Depth" instructions below.
Illustration 75 g02026392
Proper placement of the filter within the banding
(1) Outside Can
(2) Bent-over flange
(3) Steel fiber ring
(4) Mat material
(5) FilterNote: Filter must be below the bent over-flange (2).
Illustration 76 g02026398
Acceptable filter with less than 20 damaged cells
Illustration 77 g02026399
Unacceptable filter with too many damaged cells
Check Cell Depth
Check cell depth by dropping the stainless steel probe into a cell location noted by a dot in Illustration 78 below.
Lightly tap the probe with a finger until the probe does not travel into the cell any further. Mark the probe to record the depth.
Illustration 78 g02026405
Measure the distance from the tip of the probe which entered the cell to the mark made on the probe. This distance is the cell depth. Repeat this step 17 times per Illustration 78.
If the probe travels a minimum of 28.6 cm (11.25 inch) in all cells, the filter is considered clean.
If the probe encounters heavy resistance in

Have questions with 108822-3246?





Group cross 108822-3246 ZEXEL

Hino 

 
220401170A 
INJECTION-PUMP ASSEMBLY
YJ46
 
220401171A 
INJECTION-PUMP ASSEMBLY
YJ46
 
220401172A 
INJECTION-PUMP ASSEMBLY
YJ46
F 01G 09U 0H2 
 
INJECTION-PUMP ASSEMBLY

Hino 

F 01G 09U 0H3 
220401173A 
INJECTION-PUMP ASSEMBLY
YJ46
F 01G 09U 0H4 
220401174A 
INJECTION-PUMP ASSEMBLY
YJ46
108822-3246  

108822-3247 
9 400 611 408 
220401174B 
INJECTION-PUMP ASSEMBLY
F17D-TE
9 400 611 871 
220401175A 
INJECTION-PUMP ASSEMBLY
F17D-TE