108822-3221 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1088223221 220009992a


 

Information injection-pump assembly

ZEXEL 108822-3221 1088223221
HINO 220009992A 220009992a
108822-3221 INJECTION-PUMP ASSEMBLY
Rating:
74
Buy INJECTION-PUMP ASSEMBLY 108822-3221 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
108822-3221 
108822-3222 
 
220009992A  HINO
INJECTION-PUMP ASSEMBLY
YJ43 * K




Information:

Appendix
Configuration Information
Table 7
Over-Temp    
Inlet Over-Temperature Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output function     ON only during alarm    
    Assert Alarm     Above
650 °C (1202 °F)    
    Hysteresis    
20 °C (68 °F)    
    Upon Over Temperature extend alarm for 60 seconds    
Table 8
Over-Pres    
Over-Pressure Warning        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     ON only during alarm    
    Assert Alarm when the measured pressure exceeds 7" of Hg for 5% of the time during a 60 min measurement interval    
Over-Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 2    
    Output Function     Latched ON upon alarm    
    Assert alarm when the measured pressure exceeds 8" of Hg for 5% of the time during a 60 min measurement interval    
Table 9
TC-Fail (1)    
Open Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if measured temperature is above
1000 °C (1832 °F)    
Shorted Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if pressure is greater than 1" of Hg for 10 min and measured temperature does not exceed
120 °C (248 °F)    
( 1 ) Output selection applies to both open and shorted alarms
Table 10
Pressure Sensor Fail    
No Change Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Outputs During Alarm     Output 1    
    Output Function     Latched ON upon Alarm    
    Assert alarm if exhaust temperature is above
250 °C (482 °F) for 10 min and the pressure doesn't change by at least 0.25" of Hg    
Negative Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     Latched ON during alarm    
    Assert Alarm if temperature is above
200 °C (392 °F) for 10 min and the pressure is less than −1" of

Have questions with 108822-3221?





Group cross 108822-3221 ZEXEL

Hino 

 
220009990A 
INJECTION-PUMP ASSEMBLY
YJ43
108822-3221  

108822-3222 
 
220009992A 
INJECTION-PUMP ASSEMBLY
YJ43
 
220009993A 
INJECTION-PUMP ASSEMBLY
YJ43
F 01G 09U 0GY 
 
INJECTION-PUMP ASSEMBLY

Hino 

F 01G 09U 0GZ 
220009994A 
INJECTION-PUMP ASSEMBLY
YJ43
F 01G 09U 0H0 
220009995A 
INJECTION-PUMP ASSEMBLY
YJ43
F 01G 09U 0H1 
220009995B 
INJECTION-PUMP ASSEMBLY
F21C-B
9 400 611 808 
220009996A 
INJECTION-PUMP ASSEMBLY
F21C-B
9 400 619 355 
220009997A 
INJECTION-PUMP ASSEMBLY
F21C-B
Back to top