108622-3865 ZEXEL 9 400 612 597 BOSCH INJECTION-PUMP ASSEMBLY 9400612597 1086223865 220401786a


 

Information injection-pump assembly

BOSCH 9 400 612 597 9400612597
ZEXEL 108622-3865 1086223865
HINO 220401786A 220401786a
108622-3865 INJECTION-PUMP ASSEMBLY
Rating:
10
Buy INJECTION-PUMP ASSEMBLY 108622-3865 zexel genuine, new aftermarket engine parts with delivery

Service parts 108622-3865 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108062-4060
3. GOVERNOR 105923-4542
4. SUPPLY PUMP 105237-5210
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-0740
7. COUPLING PLATE 156638-7720
9. _
10. NOZZLE AND HOLDER ASSY 105101-8451
11. Nozzle and Holder 23600-3270B
12. Open Pre:MPa(Kqf/cm2) 16.7{170}/27.5{280}
13. NOZZLE-HOLDER 105030-3750
14. NOZZLE
15. NOZZLE SET 105019-2220

Include in #1:

108622-3865 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
108622-3865 
108622-3866 
9 400 612 597 
220401786A  HINO
INJECTION-PUMP ASSEMBLY
P11C * K 14CJ TICS HD-TI6M TICS




Information:

Proper operation and maintenance are key factors in obtaining the maximum life and economy of the engine. Following the directions in this manual will lower operating costs.The time needed for the engine to reach the normal mode of operation is usually less than the time taken for a walk-around-inspection of the engine.After the engine is started and the cold low idle operation is completed, the engine can be operated at rated speed and low power. The engine will reach normal operating temperature faster when operated at rated speed and low power demand than when idled at no load. Typically the engine should be up to operating temperature in a few minutes.Governors and Actuators
Your engine may be equipped with a:* full-range governor* Woodward PSG Governor* Woodward 1724 Actuator* Woodward 524 Actuator
PSG Actuator
1724/524 ActuatorWoodward Governors/Actuators are usually electrically operated from a control panel. The application is usually an EPG power generator set. On standby gen sets the governor may be set to operate only at Full Load Speed.Change Engine Speed
If equipped with a control panel, a RAISE/LOWER switch or a speed setting potentiometer is used to adjust the operating speed.Starting, Operating and Stopping Engines Equipped with Control Panels
For all information regarding the generator control panel used for starting, operating and stopping the engine, refer to the Engine Protection Devices Generator Set Control Panel topic in this publication or Caterpillar SR4 Generators and Control Panels, SEBU6150. Additional information and programming instructions are provided in the Service Manual for your specific control panel.Mechanical Governors (If Equipped)
Governor Control LeverYour engine may be equipped with a full-range governor. Most other manufacturers' engines have min-max type governors that only govern at high and low idle to prevent the engine from overspeeding or dying. With the min-max governor, the position of the speed lever determines the amount of fuel delivered to the engine.With the full-range governor, the position of the speed lever sets engine speed and helps hold a constant speed independent of load which makes operation easier.The governor control motor is a 24 volt motor which allows for engine speed control from a remote location through a governor RAISE/LOWER switch. This governor control switch is used with the optional EMCP II. Always increase engine speed to high idle before applying load.For information regarding initial checks and adjustments, refer to the Service Manual or contact your Caterpillar dealer.Driven Equipment Without Load
1. Move the governor control lever to half engine speed.2. Interrupted starts put excessive stress on the drive train and waste fuel. To get the driven equipment in motion, engage the clutch smoothly, with no load on the equipment. This should result in a smooth, easy start without increasing the engine speed above low idle or slipping the clutch. For generator sets, move the governor control to high idle (full load) position (1800 rpm for 60 Hz and 1500 rpm for 50 Hz).3. Apply the load and check the gauges and equipment for proper operation. Begin operating the engine at low load. After normal oil pressure

Have questions with 108622-3865?





Group cross 108622-3865 ZEXEL

Hino 

 
220401780A 
INJECTION-PUMP ASSEMBLY
P11C
 
220401783A 
INJECTION-PUMP ASSEMBLY
P11C
 
220401784A 
INJECTION-PUMP ASSEMBLY
P11C
9 400 612 322 
220401784B 
INJECTION-PUMP ASSEMBLY
P11C
F 01G 09U 0FZ 
220401785A 
INJECTION-PUMP ASSEMBLY
P11C
108622-3865  

108622-3866 
9 400 612 597 
220401786A 
INJECTION-PUMP ASSEMBLY
P11C
F 01G 09U 0G0 
220401787A 
INJECTION-PUMP ASSEMBLY
P11C
9 400 619 206 
220401788A 
INJECTION-PUMP ASSEMBLY
P11C
9 400 619 206 
S220401788 
INJECTION-PUMP ASSEMBLY
P11C
Back to top