108622-3527 ZEXEL 9 400 619 183 BOSCH INJECTION-PUMP ASSEMBLY 9400619183 1086223527 220009424a


 

Information injection-pump assembly

BOSCH 9 400 619 183 9400619183
ZEXEL 108622-3527 1086223527
HINO 220009424A 220009424a
108622-3527 INJECTION-PUMP ASSEMBLY
Rating:
19
Buy INJECTION-PUMP ASSEMBLY 108622-3527 zexel genuine, new aftermarket engine parts with delivery

Service parts 108622-3527 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108062-3372
3. GOVERNOR 105952-1844
4. SUPPLY PUMP 105237-4670
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-0740
7. COUPLING PLATE 156639-3221
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-7892
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 16.7(170)/23.5(240)
13. NOZZLE-HOLDER 105030-3612
14. NOZZLE 105025-0620
15. NOZZLE SET

Include in #1:

108622-3527 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
108622-3527 
9 400 619 183 
220009424A  HINO
INJECTION-PUMP ASSEMBLY
K-4 K




Information:


Before any service work is to be done on the fuel system, the outer surface of the injection pump housing must be clean.
Illustrations show fuel injection pump housing and governor removed from engines. Service work can be done with it installed on engine. 1. Remove the flange (1) and flange assembly (2) from the cover (3).2. Remove the cover from the pump housing by removing seven bolts. 3. Remove the solenoid (4) from the cover.4. Remove cover (6).5. Remove two bolts (5) that hold the cover to the shutoff housing. 6. Remove the cover from the shutoff housing (7). 7. Remove the lever (10) from the shaft (11).8. Remove the shaft (9) from the shutoff housing.9. Remove the lever (8) from the shaft (11).10. Remove the shaft (11) from the shutoff housing.11. Remove the seal (12) from the shutoff housing.Install Shutoff Housing
1. Put 5S1454 Sealing Compound on the outside diameter of the seal and install the seal (1) with tooling (A) in the shutoff housing with the lip toward the outside. The outer face of the seal must be .039 in. (1.0 mm) below the surface of the housing. Remove the extra sealing compound from the housing and the seal after installation. 2. Install the shaft (3) in the shutoff housing.3. Install the lever (5) on the shaft (3).4. Install shaft (2) in the shutoff housing.5. Install the lever (4) on shaft (3). 6. Put the cover (6) in position on the shutoff housing and install two bolts that hold the cover to the housing. 7. Install the cover (8).8. Install the solenoid (7) on the cover.9. Install the cover (6) on the pump housing.10. Install the flange assembly and the flange on the cover.

Have questions with 108622-3527?





Group cross 108622-3527 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY

Hino 

 
220009420A 
INJECTION-PUMP ASSEMBLY
K-4
 
220009421A 
INJECTION-PUMP ASSEMBLY
K-4
 
220009422A 
INJECTION-PUMP ASSEMBLY
K-4
 
220009422B 
INJECTION-PUMP ASSEMBLY
K-4
 
220009423A 
INJECTION-PUMP ASSEMBLY
K-4
F 019 Z20 507 
220009423B 
INJECTION-PUMP ASSEMBLY
K-4
108622-3527  
9 400 619 183 
220009424A 
INJECTION-PUMP ASSEMBLY
K-4
Back to top