Information injection-pump assembly
ZEXEL
108622-0020
1086220020

Rating:
Cross reference number
ZEXEL
108622-0020
1086220020
Zexel num
Bosch num
Firm num
Name
108622-0020
INJECTION-PUMP ASSEMBLY
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve
132424-0620
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
RED3 control unit part number
407910-2
470
RED3 rack sensor specifications
mm
15
PS/ACT control unit part no.
407980-2
24*
Digi switch no.
21
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
6.4
6.37
6.43
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-4 deg. 60 59.75 60.25
Cal 1-4 deg. 60 59.75 60.25
Difference between angles 2
Cyl.1-2 deg. 120 119.75 120.25
Cyl.1-2 deg. 120 119.75 120.25
Difference between angles 3
Cal 1-6 deg. 180 179.75 180.25
Cal 1-6 deg. 180 179.75 180.25
Difference between angles 4
Cal 1-3 deg. 240 239.75 240.25
Cal 1-3 deg. 240 239.75 240.25
Difference between angles 5
Cal 1-5 deg. 300 299.75 300.25
Cal 1-5 deg. 300 299.75 300.25
Injection quantity adjustment
Rack position
(12.9)
Vist
V
1.41
1.41
1.41
Pump speed
r/min
650
650
650
Average injection quantity
mm3/st.
177.6
175.6
179.6
Max. variation between cylinders
%
0
-4
4
Basic
*
PS407980-224*
V
V1+0.51+
-0.01
PS407980-224*
mm
5.4+-0.0
3
Remarks
Refer to items regarding the pre-stroke actuator
Refer to items regarding the pre-stroke actuator
Injection quantity adjustment_02
Rack position
(7.7)
Vist
V
2.5
2.4
2.6
Pump speed
r/min
225
225
225
Average injection quantity
mm3/st.
8
7
9
Max. variation between cylinders
%
0
-10
10
PS407980-224*
V
V1+0.51+
-0.01
PS407980-224*
mm
5.4+-0.0
3
0000001201
Pre-stroke
mm
6.4
6.37
6.43
Remarks
When the timing sleeve is pushed up
When the timing sleeve is pushed up
_02
Connector angle
deg.
5
4.5
5.5
Remarks
When the eccentric pin is tightened
When the eccentric pin is tightened
_03
Supply voltage
V
24
23.5
24.5
Ambient temperature
degC
23
18
28
Pre-stroke
mm
6.4
6.37
6.43
Output voltage
V
1.2
1.05
1.35
Adjustment
*
Remarks
Output voltage V1
Output voltage V1
_04
Supply voltage
V
24
23.5
24.5
Ambient temperature
degC
23
18
28
Pre-stroke
mm
3.4
3.12
3.68
Output voltage
V
2.7
2.53
2.87
Confirmation
*
_05
Supply voltage
V
24
23.5
24.5
Ambient temperature
degC
23
18
28
Output voltage
V
2.85
2.85
Confirmation of operating range
*
Test data Ex:
Speed control lever angle

N:Pump normal
S:Stop the pump.
(1)Rack position = aa
(2)Rack position bb
----------
aa=1mm bb=16mm
----------
a=12deg+-5deg b=29deg+-5deg
----------
aa=1mm bb=16mm
----------
a=12deg+-5deg b=29deg+-5deg
0000000901

(1)Pump vertical direction
(2)Coupling's key groove position at No 1 cylinder's beginning of injection
(3)Pre-stroke: aa
(4)-
----------
aa=6.4+-0.03mm
----------
a=(30deg)
----------
aa=6.4+-0.03mm
----------
a=(30deg)
0000001701

(Rs) rack sensor specifications
(C/U) control unit part number
(V) Rack sensor output voltage
(R) Rack position (mm)
1. Confirming governor output characteristics (rack 15 mm, span 6 mm)
(1)When the output voltages of the rack sensor are V1 and V2, check that the rack positions R1 and R2 in the table above are satisfied.
----------
----------
----------
----------
Information:
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
There have been instances of DEF manifold return fittings being blocked due to incomplete drilling of the fitting. This issue affects 462-3219 DEF Manifold Gp, 462-3232 DEF Manifold Gp, and 462-3610 DEF Manifold Gp.The following event codes may become active due to this issue:
Table 1
J1939 Code and Description CDL Code and Description
4334-16
Aftertreatment #1 DEF #1 Pressure (absolute) : High - moderate severity (2) E930 (2)
High Aftertreatment #1 DEF Pressure
5392-31
Aftertreatment Diesel Exhaust Fluid Dosing Unit Loss of Prime E1370 (2)
Aftertreatment #1 DEF Dosing Unit Loss of Prime Solution
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Illustration 1 g06565786
View of the return fitting on the DEF manifold
(1) Example of a blocked return fitting
Inspect DEF manifold return fitting (1) for blockage due to incomplete drilling. Refer to Illustration 1.
If the manifold fitting is not drilled completely, record the part number and serial number of the manifold from the label.
Submit a Dealer Solutions Network (DSN) ticket for part return.
Replace the suspect manifold with a new part. Inspect the new part for a correctly drilled manifold before installation.
If the manifold fitting is drilled completely, install the manifold. Follow the correct troubleshooting procedure for any active diagnostic codes. Refer to Troubleshooting.
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
There have been instances of DEF manifold return fittings being blocked due to incomplete drilling of the fitting. This issue affects 462-3219 DEF Manifold Gp, 462-3232 DEF Manifold Gp, and 462-3610 DEF Manifold Gp.The following event codes may become active due to this issue:
Table 1
J1939 Code and Description CDL Code and Description
4334-16
Aftertreatment #1 DEF #1 Pressure (absolute) : High - moderate severity (2) E930 (2)
High Aftertreatment #1 DEF Pressure
5392-31
Aftertreatment Diesel Exhaust Fluid Dosing Unit Loss of Prime E1370 (2)
Aftertreatment #1 DEF Dosing Unit Loss of Prime Solution
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Illustration 1 g06565786
View of the return fitting on the DEF manifold
(1) Example of a blocked return fitting
Inspect DEF manifold return fitting (1) for blockage due to incomplete drilling. Refer to Illustration 1.
If the manifold fitting is not drilled completely, record the part number and serial number of the manifold from the label.
Submit a Dealer Solutions Network (DSN) ticket for part return.
Replace the suspect manifold with a new part. Inspect the new part for a correctly drilled manifold before installation.
If the manifold fitting is drilled completely, install the manifold. Follow the correct troubleshooting procedure for any active diagnostic codes. Refer to Troubleshooting.
Have questions with 108622-0020?
Group cross 108622-0020 ZEXEL
Nissan-Diesel
Nissan-Diesel
Nissan-Diesel
108622-0020
INJECTION-PUMP ASSEMBLY