107692-2230 ZEXEL 9 400 619 055 BOSCH INJECTION-PUMP ASSEMBLY 9400619055 1076922230 me170277


 

Information injection-pump assembly

BOSCH 9 400 619 055 9400619055
ZEXEL 107692-2230 1076922230
MITSUBISHI ME170277 me170277
107692-2230 INJECTION-PUMP ASSEMBLY
Rating:
25
Buy INJECTION-PUMP ASSEMBLY 107692-2230 zexel genuine, new aftermarket engine parts with delivery

Service parts 107692-2230 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 107069-0181
3. GOVERNOR 105933-0950
4. SUPPLY PUMP 105237-6210
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105663-0840
7. COUPLING PLATE
10. NOZZLE AND HOLDER ASSY 105110-7360
11. Nozzle and Holder ME075583
12. Open Pre:MPa(Kqf/cm2) 15.7{160}/21.6{220}
13. NOZZLE-HOLDER 105041-3110
14. NOZZLE
15. NOZZLE SET 105019-0340

Include in #1:

107692-2230 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
107692-2230 
9 400 619 055 
ME170277  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D16T5 K 14CG INJECTION PUMP ASSY TICS MD-TI6 TICS




Information:

Coolant Water
The minerals (calcium and magnesium) in hard water can combine with cooling system conditioner additives (silicates and phosphates) to drop out of solution and collect inside the radiator.The minerals (silicates, phosphates, calcium and magnesium) can also accumulate onto hot engine surfaces and reduce the effectiveness of the cooling system, especially after a number of heating and cooling cycles.Distilled water is recommended because of less mineral drop out (potential or severity) than hard or tap water. Tap water, artificially softened with salt, is not recommended for use in your engine's cooling system. Use water that meets the minimum acceptable water requirement to prevent drop-out of these chemical compounds.To determine your water characteristics, contact the local water department, agricultural agent or an independent laboratory to perform the testing service.Antifreeze
Caterpillar recommends that the coolant mix contain a minimum of 30% Caterpillar Antifreeze, or equivalent and acceptable water to maintain an adequate cavitation temperature for efficient water pump performance.Premix coolant solution to provide protection to the lowest expected outside (ambient) temperature. Pure undiluted antifreeze will freeze at -10°F (-23°C).Only use a greater concentration (above 30%) of Caterpillar Antifreeze as needed for anticipated outside (ambient) temperatures. Do not exceed a coolant mixture of 60% antifreeze to water since a concentration above 60% antifreeze will reduce the engine's freeze protection and increase the possibility of deposit formation in the cooling system.
Use Caterpillar Antifreeze or ASTM D4985-89 (GM Specification 6038-M) Antifreeze. Caterpillar Antifreeze is available through your Caterpillar dealer in quantities that follow. Most commercial antifreezes are formulated for gasoline engine applications and will, therefore, have high silicate content. Caterpillar Antifreeze is formulated with a low silicate content and the proper coolant additives for heavy duty diesel engines. Caterpillar does not recommend use of high silicate antifreeze in the 3176 engine.ASTM D4985-89 (GM Specification 6038-M) is a low silicate antifreeze, but supplemental coolant additive must be added. Make proper antifreeze additions.Adding pure antifreeze as a makeup solution for cooling system top-off is an unacceptable practice. It increases the concentration of antifreeze in the cooling system which increases the concentration of dissolved solids and undissolved chemical inhibitors in the cooling system. Add antifreeze mixed with acceptable water to the same freeze protection as your cooling system. Use the chart below to assist in determining the concentration of antifreeze to use. Check the coolant solution frequently in cold weather for glycol concentration with the 5P0957 or 5P3514 Coolant Tester to ensure adequate protection. Both testers are identical except temperature scale. They give immediate, accurate readings and can be used for antifreeze/coolants that contain ethylene or propylene glycol. Both are available at your Caterpillar dealer.If propylene glycol based antifreeze is used, DO NOT allow concentration greater than a 50/50 antifreeze to water mixture. The measurement of freeze protection must be made with a refractive-type tester (5P0957 or 5P3514) rather than a hydrometer-type, which can be used to test ethylene glycol based antifreeze.Supplemental Coolant Additive (Conditioner)
Supplemental coolant additive (conditioner) is necessary to prevent rust, scale, pitting and/or corrosion

Have questions with 107692-2230?





Group cross 107692-2230 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 619 052 
ME072973 
INJECTION-PUMP ASSEMBLY
6D16T5
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 619 053 
ME170280 
INJECTION-PUMP ASSEMBLY
6D16T5
9 400 619 054 
ME170276 
INJECTION-PUMP ASSEMBLY
6D16T5
107692-2230  
9 400 619 055 
ME170277 
INJECTION-PUMP ASSEMBLY
6D16T5
9 400 619 056 
ME170278 
INJECTION-PUMP ASSEMBLY
6D16T5
9 400 619 057 
ME170279 
INJECTION-PUMP ASSEMBLY
6D16T5
9 400 619 058 
ME170424 
INJECTION-PUMP ASSEMBLY
6D16T5
9 400 619 059 
ME170425 
INJECTION-PUMP ASSEMBLY
6D16T5
9 400 619 060 
ME170426 
INJECTION-PUMP ASSEMBLY
6D16T5
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
9 400 611 644 
 
INJECTION-PUMP ASSEMBLY
6D16T2

Mitsubishi 

9 400 613 240 
ME170438 
INJECTION-PUMP ASSEMBLY
6D16T2
Back to top