107692-2070 ZEXEL F 019 Z10 720 BOSCH INJECTION-PUMP ASSEMBLY f019z10720 1076922070


 

Information injection-pump assembly

BOSCH F 019 Z10 720 f019z10720
ZEXEL 107692-2070 1076922070
107692-2070 INJECTION-PUMP ASSEMBLY
Rating:
47
Buy INJECTION-PUMP ASSEMBLY 107692-2070 zexel genuine, new aftermarket engine parts with delivery

Service parts 107692-2070 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 107069-0030
3. GOVERNOR 105933-0080
4. SUPPLY PUMP 105237-6130
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105663-0810
7. COUPLING PLATE 156638-6520
9. _
10. NOZZLE AND HOLDER ASSY 105101-7291
11. Nozzle and Holder ME076742
12. Open Pre:MPa(Kqf/cm2) 15.7(160)/21.6(220)
13. NOZZLE-HOLDER 105030-3420
14. NOZZLE
15. NOZZLE SET 105019-0080

Include in #1:

107692-2070 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
107692-2070 
107691-2200 
F 019 Z10 720 
  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D17 * K




Information:

Electric Starting
Startability will be improved at temperatures below 16°C (60°F) by the use of a starting aid. A jacket water (coolant) heater or other means can be used to heat the crankcase oil.Start the engine using the following procedure:1. Perform all before-starting inspections.2. If the engine is equipped with a manual control, ensure that is in the RUN position. Place the transmission in NEUTRAL (and disengage the flywheel clutch, if equipped). For Generator Sets, open the main electrical circuit breaker.2. Move throttle to approximately half engine speed to get the fuel rack to move to the FUEL ON position.3. Turn the starter switch to START (or battery disconnect switch to the ON position) or the Engine Control Switch (ECS) to MAN. START. The starting motor will crank and attempt to start the engine. At temperatures below 0°C (32°F), it may be necessary to spray starting fluid into the air cleaner inlet. Additional injections of ether may be required to start and/or achieve low idle speed.
Excessive ether can cause piston and ring damage. When using starting fluid, follow the manufacturer's instructions carefully, use it sparingly and spray it ONLY WHILE CRANKING THE ENGINE. Failure to do so could result in an explosion and/or fire and possible personal injury.Use ether for cold starting purposes only.
Do not crank the engine for more than 30 seconds.
If a warm engine fails to start within 30 seconds: release the starter switch and wait two minutes to allow the starter motor to cool before using it again.4. As soon as the engine starts, allow the engine to idle for 3 to 5 minutes, or until the water temperature gauge indicator has begun to rise. The engine should run at low idle smoothly until speed is gradually increased to high idle.
Do not increase engine speed until the oil pressure gauge indicates normal. Oil pressure should rise within 15 seconds after the engine starts. If oil pressure is not indicated on gauge within 15 seconds, stop the engine, investigate and correct the cause.
5. Allow white smoke to clear up and proceed with normal operation. Do not apply load to the engine or increase engine speed until the oil pressure gauge indicates normal. Oil pressure should raise within 15 seconds after the engine starts. For starting in cold weather, to minimize white smoke: start the engine and allow the engine to idle for 30 seconds. Increase rpm until engine speed reaches 1200 rpm. Then allow the engine to return to low idle.6. Operate the engine at low load until all systems reach operating temperature. Check all gauges during the warm-up period.Engine Starting With Jumper Cables
When boost starting an engine, follow the instructions to properly start the engine. This engine is equipped with a 12 or 24 volt starting system. Use only equal voltage for boost starting. The use of higher voltage will damage the electrical system.
Batteries give off flammable fumes that can explode.Improper jumper cable connections can cause an explosion resulting in personal injury.Prevent sparks near the batteries.

Have questions with 107692-2070?





Group cross 107692-2070 ZEXEL

Mitsubishi 

 
ME086635 
INJECTION-PUMP ASSEMBLY
6D31T2
 
ME086662 
INJECTION-PUMP ASSEMBLY
6D31T2
F 019 Z10 715 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

F 019 Z10 716 
 
INJECTION-PUMP ASSEMBLY
6D31T2
F 019 Z10 717 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

F 019 Z10 718 
 
INJECTION-PUMP ASSEMBLY
6D31T2
9 400 619 040 
 
INJECTION-PUMP ASSEMBLY
6D17
9 400 619 041 
 
INJECTION-PUMP ASSEMBLY
6D16T5
F 019 Z10 719 
 
INJECTION-PUMP ASSEMBLY
6D16T5
107692-2070  

107691-2200 
F 019 Z10 720 
 
INJECTION-PUMP ASSEMBLY
6D17
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 619 042 
ME075629 
INJECTION-PUMP ASSEMBLY
6D16T5
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 619 043 
ME075607 
INJECTION-PUMP ASSEMBLY
6D16T5
Back to top