Information injection-pump assembly
BOSCH
9 400 613 408
9400613408
ZEXEL
107692-1671
1076921671
ISUZU
8976021530
8976021530

Rating:
Service parts 107692-1671 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
7.
COUPLING PLATE
11.
Nozzle and Holder
8-94390-795-4
12.
Open Pre:MPa(Kqf/cm2)
18.1{185}/22.1{225}
14.
NOZZLE
Include in #1:
107692-1671
as INJECTION-PUMP ASSEMBLY
Cross reference number
Zexel num
Bosch num
Firm num
Name
107692-1671
9 400 613 408
8976021530 ISUZU
INJECTION-PUMP ASSEMBLY
6HH1 K 14CG INJECTION PUMP ASSY TICS MD-TI6 TICS
6HH1 K 14CG INJECTION PUMP ASSY TICS MD-TI6 TICS
Information:
Prior to stopping an engine that is being operated at low loads, run the engine at low idle for 30 seconds before stopping. But, if the engine is being operated at highway speeds and/or high loads, then it should be run at low idle for three minutes to reduce and stabilize internal engine temperature before stopping.To stop the engine, use the method listed that applies to the shutoff system on your truck.1. Turn the key switch to the OFF position, or2. ... pull OUT the manual shutoff control (if equipped), or3. ... push IN and hold the stop button until the engine stops, then release the button.Make sure the shutoff procedure is understood. Refer to the truck manufacturer's instructions for your type of engine shutoff system used. Fill the fuel tank at the end of each day of operation to drive out moist air and to prevent condensation. Do not fill the tank to the top. Fuel expands as it gets warm and may overflow.Manual Fuel Shutoff Lever
A manual shutdown lever is provided to override the governor control of the engine. The manual shutoff solenoid override lever is located on the side of the fuel pump. This shutdown will only move the fuel control linkage to the FUEL-OFF position. It does not shut off the air inlet. Shutoff Solenoid Override
The manual shutoff solenoid override lever is located on the side of the electronic governor. The engine can be shut OFF by rotating and holding the manual shutoff lever in the counterclockwise (CCW) direction. Rotating and holding the manual shutoff lever in the clockwise (CW) direction overrides the shutoff solenoid. The lever is spring loaded and will return to the neutral position when released.If the solenoid has been disabled, the engine cannot be shut OFF from inside the cab. The engine can be shut OFF by using the manual shutoff lever as an emergency shutoff lever.
DO NOT operate the engine without the rack actuator solenoid (BTM) in place and with the fuel shutoff solenoid disabled. Excessive engine speed (overspeed) may result.
A manual shutdown lever is provided to override the governor control of the engine. The manual shutoff solenoid override lever is located on the side of the fuel pump. This shutdown will only move the fuel control linkage to the FUEL-OFF position. It does not shut off the air inlet. Shutoff Solenoid Override
The manual shutoff solenoid override lever is located on the side of the electronic governor. The engine can be shut OFF by rotating and holding the manual shutoff lever in the counterclockwise (CCW) direction. Rotating and holding the manual shutoff lever in the clockwise (CW) direction overrides the shutoff solenoid. The lever is spring loaded and will return to the neutral position when released.If the solenoid has been disabled, the engine cannot be shut OFF from inside the cab. The engine can be shut OFF by using the manual shutoff lever as an emergency shutoff lever.
DO NOT operate the engine without the rack actuator solenoid (BTM) in place and with the fuel shutoff solenoid disabled. Excessive engine speed (overspeed) may result.
Have questions with 107692-1671?
Group cross 107692-1671 ZEXEL
Isuzu
Isuzu
Isuzu
Isuzu
Isuzu
Isuzu
Isuzu
107692-1671
9 400 613 408
8976021530
INJECTION-PUMP ASSEMBLY
6HH1
6HH1