107691-2111 ZEXEL 9 400 618 888 BOSCH INJECTION-PUMP ASSEMBLY 9400618888 1076912111 me075494


 

Information injection-pump assembly

BOSCH 9 400 618 888 9400618888
ZEXEL 107691-2111 1076912111
MITSUBISHI ME075494 me075494
107691-2111 INJECTION-PUMP ASSEMBLY
Rating:
21
Buy INJECTION-PUMP ASSEMBLY 107691-2111 zexel genuine, new aftermarket engine parts with delivery

Service parts 107691-2111 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 107069-0040
3. GOVERNOR 105956-0001
4. SUPPLY PUMP 105237-6210
5. AUTOM. ADVANCE MECHANIS 105681-5260
6. COUPLING PLATE 105663-0840
7. COUPLING PLATE
9. _
10. NOZZLE AND HOLDER ASSY 105118-7114
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 15.7(160)/21.6(220)
13. NOZZLE-HOLDER 105048-3883
14. NOZZLE
15. NOZZLE SET 105019-1490

Include in #1:

107691-2111 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
107691-2111 
9 400 618 888 
ME075494  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D16T5 K




Information:

Procedure
Note: Prior to performing the analysis with the APC, be sure to read and understand all the interferences listed in the "Interferences Inherent In the Fuel Sample" section of this document. Ensure that all precautions have been taken to minimize the affect of skewed results due to improper sampling, handling, or preparation.
Obtain the fuel sample to be analyzed in an appropriate sample bottle as described in the "Fuel Sample Preparation" section. Manually or mechanically shake the sample vigorously for 30 seconds. When manually shaking a sample, ensure thorough mixing of the sample by turning the bottle so that the lid is facing downward. Shake by moving the wrist and/or forearm up and down as rapidly as is comfortable for the 30 seconds.Note: Degassing samples can be accomplished with either the use of an ultrasonic bath or with the use of a vacuum pump.
Immediately degas the sample, by partially opening the lid to the bottle and placing the sample upright in the degassing unit. Perform only one of the degassing methods. An ultrasonic bath is the best method for degassing a sample. An ultrasonic bath takes the least amount of time minimizing the impact of particle settling.Note: The purpose of partially unscrewing or opening the lid is to promote quick degassing of the sample. Air bubbles to remaining near the surface of the sample following the degassing process are acceptable.
Illustration 5 g01741117
If an ultrasonic bath is unavailable, an alternative method of degassing the sample is with the use of a 1U-5718 Oil Sampling Vacuum Pump. Ensure the 1U-5718 Oil Sampling Vacuum Pump is clean before beginning the degas process.Note: Rubber is to be placed over the hole of the tubing for the pump to develop and hold the required vacuum.
With the sample to be analyzed in the sample bottle, thread the bottle into the bottom of the 1U-5718 Oil Sampling Vacuum Group. Operate the pump to create a vacuum. Maintain the vacuum until all air bubbles have risen to the surface of the sample and dissipated.
If an ultrasonic bath or a vacuum pump is not available, the sample can degas naturally. Degas the sample by setting the sample on a flat surface and leaving the sample undisturbed. If the APC performs a flushing cycle, let the sample sit for 15 seconds. If the APC does not perform a flushing cycle, such as the 293-8413 HYDAC Contamination Monitor Group or the 383-4255 HYDAC Contamination Monitor Group, let the sample sit for 30 seconds. Proceed to the "Sample Processing" section.Sample Processing
Remove the lid from the sample bottle. Immediately begin the processing of the sample on the APC that has been prepared according to the "Fuel Sample Preparation" section.Note: If more than 45 seconds elapse after the shaking of the sample, the procedure shall be restarted with shaking of the sample in "Fuel Sample Preparation" section. Shaking the sample ensures that suspended particles do not settle to the bottom of the sample, causing inaccurate particle count results.
Obtain the particle count results

Have questions with 107691-2111?





Group cross 107691-2111 ZEXEL

F 019 Z10 713 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 064 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 618 887 
ME075404 
INJECTION-PUMP ASSEMBLY
6D16T5
F 019 Z10 714 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

107691-2111  
9 400 618 888 
ME075494 
INJECTION-PUMP ASSEMBLY
6D16T5
9 400 619 885 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 611 091 
ME075531 
INJECTION-PUMP ASSEMBLY
6D17-1
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 618 889 
ME075533 
INJECTION-PUMP ASSEMBLY
6D16T5
F 019 Z20 427 
 
INJECTION-PUMP ASSEMBLY
9 400 618 890 
 
INJECTION-PUMP ASSEMBLY
6D31T2

Mitsubishi 

F 019 Z20 325 
ME086775 
INJECTION-PUMP ASSEMBLY
6D31T2
9 400 619 565 
 
INJECTION-PUMP ASSEMBLY
9 400 618 891 
 
INJECTION-PUMP ASSEMBLY
6D31T2

Mitsubishi 

F 019 Z20 326 
ME086776 
INJECTION-PUMP ASSEMBLY
6D31T2
9 400 619 614 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 610 314 
ME086777 
INJECTION-PUMP ASSEMBLY
6D31T2
9 400 618 892 
 
INJECTION-PUMP ASSEMBLY
6D16T2
9 400 618 893 
 
INJECTION-PUMP ASSEMBLY
6D16T4
9 400 618 894 
 
INJECTION-PUMP ASSEMBLY
6D16T4
Back to top