107492-1054 ZEXEL 9 400 619 967 BOSCH INJECTION-PUMP ASSEMBLY 9400619967 1074921054 8972100510


 

Information injection-pump assembly

BOSCH 9 400 619 967 9400619967
ZEXEL 107492-1054 1074921054
ISUZU 8972100510 8972100510
107492-1054 INJECTION-PUMP ASSEMBLY
Rating:
39
Buy INJECTION-PUMP ASSEMBLY 107492-1054 zexel genuine, new aftermarket engine parts with delivery

Service parts 107492-1054 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 107049-2071
3. GOVERNOR 105934-0080
4. SUPPLY PUMP 105237-5140
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE 156639-8522
9. _
10. NOZZLE AND HOLDER ASSY 105118-6462
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105048-4510
14. NOZZLE 105017-2181
15. NOZZLE SET

Include in #1:

107492-1054 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
107492-1054 
107492-1055 
9 400 619 967 
8972100510  ISUZU
INJECTION-PUMP ASSEMBLY
4HE1-TCN * K 14CH TICS MI-TI4 TICS




Information:


Illustration 74 g02026337 Appendix D
Cleaned Filter Specification
Note: Scope: The following steps determine a properly cleaned Caterpillar filter.Note: This specification applies to filters that were cleaned of ash only. This specification is only valid subsequent to the "Recommended Cleaning Procedure". This specification should not be used to determine if soot filled filters are properly cleaned. All filters must be baked appropriately using the "Recommended Cleaning Procedure" prior to application of this specification.HEALTH AND SAFETY
Wear goggles, gloves, protective clothing, and a National Institute for Occupational Safety and Health (NIOSH) approved P95 or N95 half-face respirator when handling a used Diesel Particulate Filter or Catalytic Converter Muffler. Failure to do so could result in personal injury.
Adhere to all local Health and Safety rules and regulations. Use all the personal protective equipment listed below:
Respirator
Safety shoes
Safety glasses
Latex gloves
Lab coatRESOURCESNecessary equipment:
38 cm (15 inch) long by 0.9 mm (0.04 inch) thick stainless steel probe for "200 cpsi" (Cells/Square inch) filters
Tape measureMETHODEvaluation of a cleaned filter:Note: A filter MUST meet all criteria in this section below to be considered clean.
Inspect both inlet and outlet surfaces for oil/fuel contamination, gouges and/or cracks. No cracks may be visible. Gouges may not be exceed 4.0 mm (0.15 inch) deep.
There must be no filter movement within the filters banding. This movement is defined as the substrate moving past the bent-over flange. The filter must be even or below the bent-over flange.
There must not be any signs of the steel fiber ring coming loose or any mat material (cottony gauze) slipping past the filter. See Illustration 75 below.
The flanges are not damaged beyond repair.
There are no dents deeper than 6.4 mm (0.25 inch) in the outer can of the filter and the outer can is not cracked, torn or otherwise breached.
No more than 20 cells are allowed to be damaged (showing soot) on the outlet face of the filter. Refer to Illustrations 76 and 77.
Inspect the ash depth in the cells using the "Check Cell Depth" instructions below.
Illustration 75 g02026392
Proper placement of the filter within the banding
(1) Outside Can
(2) Bent-over flange
(3) Steel fiber ring
(4) Mat material
(5) FilterNote: Filter must be below the bent over-flange (2).
Illustration 76 g02026398
Acceptable filter with less than 20 damaged cells
Illustration 77 g02026399
Unacceptable filter with too many damaged cells
Check Cell Depth
Check cell depth by dropping the stainless steel probe into a cell location noted by a dot in Illustration 78 below.
Lightly tap the probe with a finger until the probe does not travel into the cell any further. Mark the probe to record the depth.
Illustration 78 g02026405
Measure the distance from the tip of the probe which entered the cell to the mark made on the probe. This distance is the cell depth. Repeat this step 17 times per Illustration 78.
If the probe travels a minimum of 28.6 cm (11.25 inch) in all cells, the filter is considered clean.
If the probe encounters heavy resistance in

Have questions with 107492-1054?





Group cross 107492-1054 ZEXEL

Isuzu 

9 400 612 346 
8971476410 
INJECTION-PUMP ASSEMBLY
4HE1-TCN
9 400 612 347 
8971476411 
INJECTION-PUMP ASSEMBLY
4HE1-TCN
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

 
8971476412 
INJECTION-PUMP ASSEMBLY
4HE1-TCN
107492-1054  

107492-1055 
9 400 619 967 
8972100510 
INJECTION-PUMP ASSEMBLY
4HE1-TCN
 
 
INJECTION-PUMP ASSEMBLY
4HE1-TCN
F 019 Z20 426 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 618 834 
8972100511 
INJECTION-PUMP ASSEMBLY
4HE1-TCN
Back to top