Information injection-pump assembly
BOSCH
9 400 618 724
9400618724
ZEXEL
106991-1017
1069911017
ISUZU
1156024987
1156024987

Rating:
Service parts 106991-1017 INJECTION-PUMP ASSEMBLY:
1.
_
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
15.7(160)/22.1(225)
15.
NOZZLE SET
Include in #1:
106991-1017
as INJECTION-PUMP ASSEMBLY
Cross reference number
Zexel num
Bosch num
Firm num
Name
106991-1017
9 400 618 724
1156024987 ISUZU
INJECTION-PUMP ASSEMBLY
10PD1-N K
10PD1-N K
Information:
9. If the engine oil pressure gauge does not register within 10 seconds, stop the engine by pulling up on the accelerator pedal. Have corrections made.10. Keep the engine at low idle until the systems are warm.11. Watch all gauges and indicators. They must have correct readings before moving the machine.Below 0°C (32°F)
1. Follow the steps under "Above 0°C (32°F)."
If the engine does not start after two attempts, use starting fluid. This will prevent excessive battery drain and starting motor overheating.Use starting fluid (ether) only while cranking the engine.Use sparingly, excessive ether can cause piston and ring damage.Ether is to be used for cold weather starting purposes only.
Keep batteries charged to a corrected specific gravity of 1.250 or above. Otherwise, an external electrical source may be required. 2. Use starting fluid while cranking the engine. Push the button located below the start switch, at two second intervals only. A metered amount of starting fluid (ether) is released each time the button is pushed.3. Use additional starting fluid every two seconds until the engine starts.4. Release the start switch when the engine starts. Continue to inject ether until the engine runs smoothly.For starting below - 18°C (0°F), use additional starting aids. A coolant
1. Follow the steps under "Above 0°C (32°F)."
If the engine does not start after two attempts, use starting fluid. This will prevent excessive battery drain and starting motor overheating.Use starting fluid (ether) only while cranking the engine.Use sparingly, excessive ether can cause piston and ring damage.Ether is to be used for cold weather starting purposes only.
Keep batteries charged to a corrected specific gravity of 1.250 or above. Otherwise, an external electrical source may be required. 2. Use starting fluid while cranking the engine. Push the button located below the start switch, at two second intervals only. A metered amount of starting fluid (ether) is released each time the button is pushed.3. Use additional starting fluid every two seconds until the engine starts.4. Release the start switch when the engine starts. Continue to inject ether until the engine runs smoothly.For starting below - 18°C (0°F), use additional starting aids. A coolant