106971-3123 ZEXEL 9 400 619 696 BOSCH INJECTION-PUMP ASSEMBLY 9400619696 1069713123 220007183a


 

Information injection-pump assembly

BOSCH 9 400 619 696 9400619696
ZEXEL 106971-3123 1069713123
HINO 220007183A 220007183a
106971-3123 INJECTION-PUMP ASSEMBLY
Rating:
73
Buy INJECTION-PUMP ASSEMBLY 106971-3123 zexel genuine, new aftermarket engine parts with delivery

Service parts 106971-3123 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106097-5640
3. GOVERNOR 105489-3430
4. SUPPLY PUMP 105237-1670
5. AUTOM. ADVANCE MECHANIS 105683-0020
6. COUPLING PLATE 105664-0461
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-7271
11. Nozzle and Holder 236002300A
12. Open Pre:MPa(Kqf/cm2) 14.7{150}/21.6{220}
13. NOZZLE-HOLDER 105031-7230
14. NOZZLE
15. NOZZLE SET 105019-0070

Include in #1:

106971-3123 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 619 696 9400619696
ZEXEL 106971-3123 1069713123
HINO 220007183A 220007183a


Zexel num
Bosch num
Firm num
Name
106971-3123 
106971-3124 
9 400 619 696 
220007183A  HINO
INJECTION-PUMP ASSEMBLY
V22D A * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-0820
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-10-9-4 -3-6-5-8 -7-2
Pre-stroke mm   4.8 4.74 4.8
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-10
deg.   27 26.75 27.25
Difference between angles 2
Cal 1-9
deg.   72 71.75 72.25
Difference between angles 3
Cal 1-4
deg.   99 98.75 99.25
Difference between angles 4
Cal 1-3
deg.   144 143.75 144.25
Difference between angles 5
Cal 1-6
deg.   171 170.75 171.25
Difference between angles 6
Cal 1-5
deg.   216 215.75 216.25
Difference between angles 7
Cal 1-8
deg.   243 242.75 243.25
Difference between angles 8
Cal 1-7
deg.   288 287.75 288.25
Difference between angles 9
Cyl.1-2
deg.   315 314.75 315.25
Injection quantity adjustment
Adjusting point   A
Rack position   8
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   126.4 124.4 128.4
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   8
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   128.4 122.4 134.4
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   8.15
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   130 127 133
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   E
Rack position   4.2+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   10 7 13
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Injection quantity adjustment_05
Adjusting point   F
Rack position   9.2+-0.1
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   158 155 161
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   G
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   159 159 179
Fixing the lever   *
Timer adjustment
Pump speed r/min   680--
Advance angle deg.   0 0 0
Load   1/4
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   630
Advance angle deg.   0.3
Load   1/4
Timer adjustment_03
Pump speed r/min   770--
Advance angle deg.   1 0.7 1.3
Load   4/4
Timer adjustment_04
Pump speed r/min   900+50
Advance angle deg.   1 0.7 1.3
Load   3/4
Timer adjustment_05
Pump speed r/min   1100-50
Advance angle deg.   5.25 4.95 5.55
Load   4/4
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 106971-3123
N:Pump speed R:Rack position (mm) (1)Lever ratio: RT (2)Target shim dimension: TH (3)Tolerance for racks not indicated: +-0.05mm. (4)Set idle at point K (N = N1, R = R1) and confirm that the injection quantity does not exceed Q1 at point J (N = N2). (5)Excess fuel setting for starting: SXL (6)Damper spring setting
----------
RT=1 TH=2.2mm N1=325r/min R1=4.2mm N2=1150r/min Q1=3mm3/st SXL=9.2+-0.1mm
----------

Speed control lever angle

Test data 106971-3123
F:Full speed
----------

----------
a=19.5deg+-5deg

0000000901

Test data 106971-3123
F:Full load I:Idle (1)Use the hole at R = aa (2)Stopper bolt setting
----------
aa=70mm
----------
a=28deg+-3deg b=17deg+-5deg

Stop lever angle

Test data 106971-3123
N:Pump normal S:Stop the pump.
----------

----------
a=16deg+-5deg b=64deg+-5deg

Timing setting

Test data 106971-3123
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(80deg)




Information:

6N9294 Alternator Group, 3T6352 Alternator 24V 35A (Delco-Remy Number 1117647)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 35A(1) Torque for the ground terminal nut ... 2.3 0.6 N m (21 5 lb in)(2) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(3) Torque for the output terminal nut ... 7.1 0.9 N m (64 8 lb in)3T6354 Regulator (Delco-Remy Number 1116405) Inside Alternator
Voltage setting ... No adjustmentPermissible voltage range ... 26 to 30VDelco-Remy (25SI)
5S9088 Alternator Group, 3T1888 Alternator 24V 50A (Delco-Remy Number 1117248)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output (hot) ... 50A(1) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (10 1 lb ft)7N129 Regulator (Delco-Remy Number 1892824) Inside Alternator
Voltage setting range ... 27.5 1.0VAdjust voltage setting to ... 28V There are two types of adjustment: One type of adjustment is made by removing a pipe plug and turning the adjusting screw one or two notches in a clockwise direction to increase the voltage setting or one or two notches in a counterclockwise direction to decrease the voltage setting. The second type of adjustment is similar except, remove the end cover to expose the potentiometer for adjustment.Then increase speed to get a maximum output of ... 50ABosch
6N9294 Alternator Group, 7N9720 Alternator 24V 35A (Bosch Number 0-122-469-001)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 37ATorque for the ground terminal nut ... 2.1 to 2.8 N m (19 to 25 lb in)(1) Torque for the pulley nut ... 95 to 110 N m (70 to 80 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (10 1 lb ft)9G7567 Regulator (Bosch Number 1-197-011-000) Under Alternator Cover. For

Have questions with 106971-3123?





Group cross 106971-3123 ZEXEL

Hino 

 
220007180A 
INJECTION-PUMP ASSEMBLY
V22D
 
220007181A 
INJECTION-PUMP ASSEMBLY
V22D
 
220007182A 
INJECTION-PUMP ASSEMBLY
V22D
106971-3123  

106971-3124 
9 400 619 696 
220007183A 
INJECTION-PUMP ASSEMBLY
V22D
F 01G 09U 0BW 
220007184A 
INJECTION-PUMP ASSEMBLY
V22D
9 400 618 690 
220007184B 
INJECTION-PUMP ASSEMBLY
V22D
9 400 618 690 
S220007184B 
INJECTION-PUMP ASSEMBLY
V22D
Back to top