106961-1471 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1069611471 1156018792


 

Information injection-pump assembly

ZEXEL 106961-1471 1069611471
ISUZU 1156018792 1156018792
106961-1471 INJECTION-PUMP ASSEMBLY
Rating:
83
Buy INJECTION-PUMP ASSEMBLY 106961-1471 zexel genuine, new aftermarket engine parts with delivery

Service parts 106961-1471 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106096-9191
3. GOVERNOR 105488-0310
4. SUPPLY PUMP 105237-1940
5. AUTOM. ADVANCE MECHANIS 105687-0042
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-7003
11. Nozzle and Holder 1-15300-138-2
12. Open Pre:MPa(Kqf/cm2) 15.7{160}/22.1{225}
13. NOZZLE-HOLDER 105031-4831
14. NOZZLE 105015-6250
15. NOZZLE SET

Include in #1:

106961-1471 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106961-1471 
106961-1472 
 
1156018792  ISUZU
INJECTION-PUMP ASSEMBLY
10PC1 * K




Information:


Illustration 1 g00857824
(1) Side Panel (2) Keyboard Port (3) Mouse Port (4) Mouse (5) KeyboardConnecting A Mouse And Keyboard
Plug the mouse (4) into the mouse port (3) on the side panel (1). Plug the keyboard (5) into the keyboard port (2) on the side panel (1) .DC Power Connections
A standard three-position terminal block is provided for connecting power. Use 12 AWG stranded wire or use 14 AWG stranded wire in order to connect the terminals to a 24 VDC power supply that is stable. The 24 VDC power supply must have a minimum rating of 10 A. Observe the proper polarity. The wiring should be less than 3 meters in length. Ensure that the wires are connected correctly by using standard wiring practices. Twist the wires 1 to 3 twists per inch.Note: The ground connection must be made to an adequate earth ground. Use a short length of wire. A short length of wire eliminates the possibility of radio frequency noise and interference.
Illustration 2 g00857922
Terminal BlockNetwork Connections
The monitor accommodates CAT5 twisted pair Ethernet cables. The cables have RJ45 connectors in order to support 100Mbps network data transfer.Note: The performance of the Ethernet communications will degrade if the unit is exposed to extreme radiated noise or conducted high frequency noise. The performance of the Ethernet communications will degrade if the cables are exposed to extreme radiated noise or conducted high frequency noise. The user is responsible for properly routing the cables. The user is responsible for conditioning the input power in order to improve the reliability of communication. Note: Proper routing of the cable and proper conditioning of the power is required in order to ensure reliable Ethernet communications in industrial environments. All cables should be routed through dedicated metal conduits. Installing ferrite bead filters at cable ends may also improve reliability.

Have questions with 106961-1471?





Group cross 106961-1471 ZEXEL

Isuzu 

 
1156018791 
INJECTION-PUMP ASSEMBLY
10PC1
106961-1471  

106961-1472 
 
1156018792 
INJECTION-PUMP ASSEMBLY
10PC1
F 019 Z10 911 
1156018793 
INJECTION-PUMP ASSEMBLY
10PC1
 
1156018794 
INJECTION-PUMP ASSEMBLY
10PC1
F 019 Z10 912 
1156018795 
INJECTION-PUMP ASSEMBLY
10PC1
F 019 Z10 742 
1156018796 
INJECTION-PUMP ASSEMBLY
10PC1
9 400 618 598 
1156018797 
INJECTION-PUMP ASSEMBLY
10PC1
Back to top