106961-1445 ZEXEL 9 400 618 595 BOSCH INJECTION-PUMP ASSEMBLY 9400618595 1069611445 1156015745


 

Information injection-pump assembly

BOSCH 9 400 618 595 9400618595
ZEXEL 106961-1445 1069611445
ISUZU 1156015745 1156015745
106961-1445 INJECTION-PUMP ASSEMBLY
Rating:
71
Buy INJECTION-PUMP ASSEMBLY 106961-1445 zexel genuine, new aftermarket engine parts with delivery

Service parts 106961-1445 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106096-9163
3. GOVERNOR 105488-9021
4. SUPPLY PUMP 105237-4421
5. AUTOM. ADVANCE MECHANIS 105687-0082
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-6322
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 19.6(200)
13. NOZZLE-HOLDER 105031-1741
14. NOZZLE 105015-6250
15. NOZZLE SET

Include in #1:

106961-1445 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106961-1445 
9 400 618 595 
1156015745  ISUZU
INJECTION-PUMP ASSEMBLY
10PC1 * K




Information:


Illustration 62 g02807941
Remove the plug
Remove plug (2) .
Illustration 63 g02807956
Set speed by turning adjusting screw
Adjust speed. If Ng exceeds TMI specifications, tighten the adjusting screw. If Ng is less than the specified value, loosen the adjusting screw.
Illustration 64 g02807957
Adjust the maximum-speed stopper bolt
Adjust the maximum-speed stopper bolt until the speed at the start of high-speed control is Nf.
Check that the no-load maximum speed is Ng (described in Step 1). Continue adjustment until the specified value is obtained.
Illustration 65 g02807958
Increase pump speed to make sure that the control rack position reaches Ra.
Illustration 66 g02807959
Full-load Adjustment
Illustration 67 g02807997
Install the cover and adjust full-load stopper bolt
Install cover (3) on governor using bolts and lockwashers (2). Use caution when installing the cover to make sure that the O-ring seal is in the seal groove.
Illustration 68 g02807999
Position the control lever at maximum-speed position.
Adjust full-load stopper bolt (1) to the f"ull-load fuel injection quantity" position. See TMI for the specifications (Point A).
Install cap.Control Lever Angle Measurement
Illustration 69 g02808016
Measuring control lever angle at the "full-speed" and "idling" positions.
Measuring the control lever angle at the "idling" and "full" positions.
If the angle is not as specified by TMI, replace the shifters shim. If the control lever is positioned toward the "full" position, replace the shifters shim with a thicker one. When control lever is toward the "idling" position, replace the shim with a thinner one.Check Starting Delivery
Illustration 70 g02808018
Remove measurement adapter
Remove measurement adapter (1) .
Illustration 71 g02808038
Cap must be installed to check delivery rate
Install cap (2) .
Run pump at speed specified in TMI.
Check delivery rate with specifications listed in TMI.
Stop pump rotation.
Illustration 72 g02808058
Adjusting screw for setting fuel flow
If delivery rate does not meet TMI specifications, remove cap (2), loosen lock nut, and adjust screw (3). Adjusting screw outward decreases fuel flow and inward increases fuel flow.
Install cap (2) and recheck delivery rate. Repeat Steps 2 through 6 until delivery rate is at specified value.Lockwiring Caps of Adjustment Screws
All adjustment stops (screws) that directly affect engine performance should be lockwired after adjustment. Do not readjust any stop without using the test stand can adversely affect the engine and engine performance.

Have questions with 106961-1445?





Group cross 106961-1445 ZEXEL

Isuzu 

 
1156015740 
INJECTION-PUMP ASSEMBLY
10PC1
 
1156015742 
INJECTION-PUMP ASSEMBLY
10PC1
 
1156015743 
INJECTION-PUMP ASSEMBLY
10PC1
 
1156015744 
INJECTION-PUMP ASSEMBLY
10PC1
106961-1445  
9 400 618 595 
1156015745 
INJECTION-PUMP ASSEMBLY
10PC1
Back to top