106891-1224 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1068911224 1156022314


 

Information injection-pump assembly

ZEXEL 106891-1224 1068911224
ISUZU 1156022314 1156022314
106891-1224 INJECTION-PUMP ASSEMBLY
Rating:
17
Buy INJECTION-PUMP ASSEMBLY 106891-1224 zexel genuine, new aftermarket engine parts with delivery

Service parts 106891-1224 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106089-9050
3. GOVERNOR 105488-1430
4. SUPPLY PUMP 105237-1940
5. AUTOM. ADVANCE MECHANIS 105693-0241
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-7851
11. Nozzle and Holder 1-15300-204-1
12. Open Pre:MPa(Kqf/cm2) 15.7{160}/22.1{225}
13. NOZZLE-HOLDER 105031-4831
14. NOZZLE 105015-8200
15. NOZZLE SET

Include in #1:

106891-1224 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 106891-1224 1068911224
ISUZU 1156022314 1156022314


Zexel num
Bosch num
Firm num
Name
106891-1224 
106891-1225 
 
1156022314  ISUZU
INJECTION-PUMP ASSEMBLY
8PD1-S * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve (drive side)   134424-4020
Overflow valve opening pressure (drive side) kPa   255 221 289
Overflow valve opening pressure (drive side) kgf/cm2   2.6 2.25 2.95
Overflow valve (governor side)   134424-2720
Overflow valve opening pressure (governor side) kPa   255 221 289
Overflow valve opening pressure (governor side) kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-8-7-3- 6-5-4-2
Pre-stroke mm   4.2 4.17 4.23
Rack position
Point A
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-8
deg.   45 44.75 45.25
Difference between angles 2
Cal 1-7
deg.   90 89.75 90.25
Difference between angles 3
Cal 1-3
deg.   135 134.75 135.25
Difference between angles 4
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 5
Cal 1-5
deg.   225 224.75 225.25
Difference between angles 6
Cal 1-4
deg.   270 269.75 270.25
Difference between angles 7
Cyl.1-2
deg.   315 314.75 315.25
Injection quantity adjustment
Adjusting point   A
Rack position   8.5
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   110 108.5 111.5
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   8.8
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   111.6 109.6 113.6
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   7.9
Pump speed r/min   1150 1150 1150
Average injection quantity mm3/st.   117.4 115.4 119.4
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   D
Rack position   4.9+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   8.8 7.5 10.1
Max. variation between cylinders %   0 -13 13
Fixing the rack   *

Test data Ex:

Governor adjustment

Test data 106891-1224
N:Pump speed R:Rack position (mm) (1)Tolerance for racks not indicated: +-0.05mm. (2)Damper spring setting
----------

----------

Timer adjustment

Test data 106891-1224
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1-0.2mm N2=800r/min C2=(7)deg t1=1.5--sec. t2=1.5--sec.
----------
N1=1100++r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=7+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 106891-1224
F:Full speed
----------

----------
a=7deg+-5deg

0000000901

Test data 106891-1224
F:Full load I:Idle (1)Stopper bolt setting
----------

----------
a=10deg+-5deg b=34deg+-3deg

Stop lever angle

Test data 106891-1224
N:Pump normal S:Stop the pump.
----------

----------
a=60deg+-5deg b=73deg+-5deg

0000001501 RACK SENSOR

Test data 106891-1224
V1:Supply voltage V2f:Full side output voltage V2i:Idle side output voltage (A) Black (B) Yellow (C) Red (D) Trimmer (E): Shaft (F) Nut (G) Load lever 1. Load sensor adjustment (1)Connect as shown in the above diagram and apply supply voltage V1. (2)Hold the load lever (G) against the full side. (3)Turn the shaft so that the voltage between (A) and (B) is V2. (4)Hold the load lever (G) against the idle side. (5)Adjust (D) so that the voltage between (A) and (B) is V2i. (6)Repeat the above adjustments. (7)Tighten the nut (F) at the point satisfying the standards. (8)Hold the load lever against the full side stopper and the idle side stopper. (9)At this time, confirm that the full side output voltage is V2f and the idle side output voltage is V2i.
----------
V1=5+-0.02V V2f=0.15+0.03V V2i=2.35-0.03V
----------

Timing setting

Test data 106891-1224
(1)Pump vertical direction (2)Position of "Z" mark at the No 1 cylinder's beginning of injection (governor side) (3)B.T.D.C.: aa (set timing) (4)-
----------
aa=8deg
----------
a=(180deg)




Information:

Start By:a. remove timing gear coverb. remove flywheel housingc. remove pistons and connecting rod assembliesd. remove crankshaft rear seal and wear sleevee. remove crankshaft front seal and wear sleeve Check the bearing caps for a number as to their location. If a number can not be seen, put a number on the left side of cylinder block and bearing cap. 1. Remove bolts (1) that hold main bearing caps (2) to the block, and remove main bearing caps (2). 2. Install one of the bolts from the front pulley in each end of the crankshaft.3. Fasten a hoist to crankshaft (3), and remove crankshaft (3) from the block. The weight is 159 kg (350 lb.). If new main bearings are not to be installed, keep old bearings with identification as to their location in cylinder block. 4. Use tooling (A) to remove the crankshaft gear.5. Use tooling (B) if necessary to remove the dowel and the pin.Install Crankshaft
If the crankshaft journals and bores for the block and rods were measured at disassembly and found to be within specifications, no further checks are necessary. However, if the serviceman still wants to measure the bearing clearances, Plastigage is recommended. Lead wire, shim stock or use of a dial bore gauge can damage the bearing surface.The serviceman must be very careful to use Plastigage, tool (B) correctly. The following points must be remembered:... Make sure that the backs of the bearings and the bores are clean and dry.... Make sure that the bearing locking tabs are properly seated in their slots.... The crankshaft must be free of oil where the Plastigage touches it.... If the main bearing clearances are checked with the engine upright or on its side, the crankshaft must be supported. Use a jack under an adjacent crankshaft counterweight and hold the crankshaft against the crown of the bearing. If the crankshaft is not supported, the weight of the crankshaft will cause incorrect readings.... Put a piece of Platigage on the crown of the bearing half that is in the cap. Do not allow the Plastigage to extend over the edge of the bearing.... Install the bearing cap using the correct torque-turn specifications. Do not use an impact wrench. Be careful not to dislodge the bearing when the cap is installed.... Do not turn the crankshaft with the Plastigage installed.... Carefully remove the cap but do not remove the Plastigage. Measure the width of the Plastigage while it is in the bearing cap or on the crankshaft journal. Do this by using the correct scale on the package. Record the measurements.... Remove the Plastigage before reinstalling the cap.When using Plastigage, the readings can sometimes be unclear. For example, all parts of the Plastigage are not the same width. Measure the major widths to make sure that they are within the specification range. Also, experience has shown that when checking clearances tighter than 0.10 mm (.004") the readings may be low by 0.013 to 0.025 mm (.0005 to .0010"). Out-of-round

Have questions with 106891-1224?





Group cross 106891-1224 ZEXEL

Isuzu 

 
1156022310 
INJECTION-PUMP ASSEMBLY
8PD1-S
 
1156022311 
INJECTION-PUMP ASSEMBLY
8PD1-S
 
1156022312 
INJECTION-PUMP ASSEMBLY
8PD1-S
 
1156022313 
INJECTION-PUMP ASSEMBLY
8PD1-S
106891-1224  

106891-1225 
 
1156022314 
INJECTION-PUMP ASSEMBLY
8PD1-S
 
1156022315 
INJECTION-PUMP ASSEMBLY
8PD1-S
9 400 618 537 
1156022316 
INJECTION-PUMP ASSEMBLY
8PD1-S