Information injection-pump assembly
BOSCH
9 400 618 300
9400618300
ZEXEL
106871-8770
1068718770
HINO
220007230A
220007230a

Rating:
Service parts 106871-8770 INJECTION-PUMP ASSEMBLY:
1.
_
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
23600-2240B
12.
Open Pre:MPa(Kqf/cm2)
14.7{150}/21.6{220}
14.
NOZZLE
Include in #1:
106871-8770
as INJECTION-PUMP ASSEMBLY
Cross reference number
Zexel num
Bosch num
Firm num
Name
106871-8770
9 400 618 300
220007230A HINO
INJECTION-PUMP ASSEMBLY
F17E * K 14CD PE8P PE
F17E * K 14CD PE8P PE
Information:
1. Remove two bolts (1).2. Remove fuel ratio control and gasket.Install Fuel Ratio Control
1. Put gasket (2) in position. Make an alignment with the lever in the shutoff housing with the plunger in the fuel ratio control. control.2. Install fuel ratio control (1) and the bolts that hold it.Disassemble Fuel Ratio Control
start by:a) remove fuel ratio control1. Remove solenoid (1) from the fuel ratio control. 2. Remove bolts (3) and covers (2) and (4). Remove diaphragm (11) and piston (17). Remove gasket (16) from cover (4).
Spring force is present. Slowly loosen the two bolts to release the force.
3. Remove two bolts (5), cover (6) and spring (15).
Spring force is present. Hold diaphragm assembly in position and remove pin (14).
4. Remove pin (14) and slowly release the spring force.5. Remove spring (8) and bolt (7) from housing (12).6. Remove washer (10) and diaphragm (9) from retainer (13).Assemble Fuel Ratio Control
1. Assemble washer (3), diaphragm (2) and retainer (1).2. Install bolt (4) in housing (10).3. Install spring (5), diaphragm assembly (11) and pin (6) in housing (10).4. Install spring (22) in cover (7). Install cover (7) on housing (10) with the two bolts (16) that hold it. 5. Install gasket (13) on cover (8). Install piston (14) to cover (8). Install diaphragm (15) in cover (9). 6. Put covers (8) and (9) in position on cover (7) with the bolts that hold them.7. Install solenoid (17) on the fuel ratio control. end by:a) install fuel ratio control For adjustment of fuel ratio control, see TESTING AND ADJUSTING.
1. Put gasket (2) in position. Make an alignment with the lever in the shutoff housing with the plunger in the fuel ratio control. control.2. Install fuel ratio control (1) and the bolts that hold it.Disassemble Fuel Ratio Control
start by:a) remove fuel ratio control1. Remove solenoid (1) from the fuel ratio control. 2. Remove bolts (3) and covers (2) and (4). Remove diaphragm (11) and piston (17). Remove gasket (16) from cover (4).
Spring force is present. Slowly loosen the two bolts to release the force.
3. Remove two bolts (5), cover (6) and spring (15).
Spring force is present. Hold diaphragm assembly in position and remove pin (14).
4. Remove pin (14) and slowly release the spring force.5. Remove spring (8) and bolt (7) from housing (12).6. Remove washer (10) and diaphragm (9) from retainer (13).Assemble Fuel Ratio Control
1. Assemble washer (3), diaphragm (2) and retainer (1).2. Install bolt (4) in housing (10).3. Install spring (5), diaphragm assembly (11) and pin (6) in housing (10).4. Install spring (22) in cover (7). Install cover (7) on housing (10) with the two bolts (16) that hold it. 5. Install gasket (13) on cover (8). Install piston (14) to cover (8). Install diaphragm (15) in cover (9). 6. Put covers (8) and (9) in position on cover (7) with the bolts that hold them.7. Install solenoid (17) on the fuel ratio control. end by:a) install fuel ratio control For adjustment of fuel ratio control, see TESTING AND ADJUSTING.
Have questions with 106871-8770?
Group cross 106871-8770 ZEXEL
Hino
106871-8770
9 400 618 300
220007230A
INJECTION-PUMP ASSEMBLY
F17E