106871-8665 ZEXEL F 019 Z10 886 BOSCH INJECTION-PUMP ASSEMBLY f019z10886 1068718665


 

Information injection-pump assembly

BOSCH F 019 Z10 886 f019z10886
ZEXEL 106871-8665 1068718665
106871-8665 INJECTION-PUMP ASSEMBLY
Rating:
52
Buy INJECTION-PUMP ASSEMBLY 106871-8665 zexel genuine, new aftermarket engine parts with delivery

Service parts 106871-8665 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106087-7810
3. GOVERNOR 105489-2524
4. SUPPLY PUMP 105237-4050
5. AUTOM. ADVANCE MECHANIS 105683-0000
6. COUPLING PLATE 105662-1220
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-7161
11. Nozzle and Holder 236002240B
12. Open Pre:MPa(Kqf/cm2) 14.7(150)/21.6(220)
13. NOZZLE-HOLDER 105031-7230
14. NOZZLE
15. NOZZLE SET 105019-0010

Include in #1:

106871-8665 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106871-8665 
F 019 Z10 886 
   
INJECTION-PUMP ASSEMBLY
K




Information:

The battery circuit is an electrical load on the charging unit. The load is variable because of the condition of the charge in the battery. Damage to the charging unit will result if the connections (either positive or negative) between the battery and charging unit are broken while the charging unit is in operation. This is because the battery load is lost and there is an increase in charging voltage. High voltage will damage, not only the charging unit, but also the regulator and other electrical components.Load test a battery that does not hold a charge when in use. To do this, put a resistance across the main connections (terminals) of the battery. For a 6, 8 or 12V battery, use a test load of three times the ampere/hour rating (the maximum test load on any battery is 500 amperes). Let the test load remove the charge (discharge) of the battery for 15 seconds and with the test load still applied, test the battery voltage. A 6V battery in good condition will show 4.5V; and 8V battery will show 6V; a 12V battery will show 9V. Each cell of a battery in good condition must show 1.6V on either a 6, 8 to 12V battery.Charging System
The condition of charge in the battery at each regular inspection will show if the charging system operates correctly. An adjustment is necessary when the battery is constantly in a low condition of charge or a large amount of water is needed (more than one ounce of water per cell per week or per every 50 service hours).When it is possible, make a test of the charging unit and voltage regulator on the engine, and use wiring and components that are a permanent part of the system. Off-engine (bench) testing will give a test of the charging unit and voltage regulator operation. This testing will give an indication of needed repair. After repairs are made, again make a test to give proof that the units are repaired to their original condition of operation.Before the start of on-engine testing, the charging system and battery must be checked as shown in the steps that follow:1. Battery must be at least 75% (1.225 Sp Gr) fully charged and held tightly in place. The battery holder must not put too much stress on the battery.2. Cables between the battery, starter and engine ground must be the correct size. Wires and cables must be free of corrosion and have cable support clamps to prevent stress on battery connections (terminals).3. Leads, junctions, switches and panel instruments that have direct relation to the charging circuit must give correct circuit control.4. Inspect the drive components for the charging unit to be sure they are free of grease and oil and have the ability to operate the charging unit.Alternator
Delco-Remy
No adjustment can be made

Have questions with 106871-8665?





Group cross 106871-8665 ZEXEL

Hino 

 
220801500A 
INJECTION-PUMP ASSEMBLY
F17E
 
 
INJECTION-PUMP ASSEMBLY

Hino 

 
220801501A 
INJECTION-PUMP ASSEMBLY
F17E
9 400 618 291 
220801502A 
INJECTION-PUMP ASSEMBLY
F17E
106871-8665  
F 019 Z10 886 
 
INJECTION-PUMP ASSEMBLY
Back to top