106871-2951 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1068712951 me060464


 

Information injection-pump assembly

ZEXEL 106871-2951 1068712951
MITSUBISHI ME060464 me060464
106871-2951 INJECTION-PUMP ASSEMBLY
Rating:
47
Buy INJECTION-PUMP ASSEMBLY 106871-2951 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
106871-2951 
 
ME060464  MITSUBISHI
INJECTION-PUMP ASSEMBLY
8DC9T2 * K




Information:


Illustration 1 g00565249The test for the water temperature contactor switch is a test for the temperature on the switch actuator and an electrical continuity test. This test will determine if the water temperature contactor switch is faulty and if the switch should be replaced. Use the 4C-6500 Digital Thermometer and the 4C-6500 Digital Thermometer for this test.
Install a probe from the 4C-6500 Digital Thermometer in the water manifold as close as possible to the water temperature contactor switch. Disconnect the connector for the water temperature contactor switch from the junction box. Note: Do not remove the water temperature contactor switch from the engine in order to conduct this test. The water temperature contactor switch uses the coolant flow and the coolant temperature in order to activate the switch at the actuation temperature.
When the water temperature contactor switch is disconnected from the junction box and the engine is stopped, check the continuity across the contact (WTS-3) and the common contact (WTS-2). Continuity should exist. This indicates that the circuit is closed across the contacts. Check the continuity across contact (WTS-1) and the common contact (WTS-2). Continuity should not exist. This indicates that the circuit is open across the contacts. If these conditions do not exist, the water temperature contactor switch is faulty and the switch needs to be replaced.
Start the engine. While the engine is running, place a load on the engine. Restrict the air flow to the engine. The engine should continue to run and the coolant temperature should increase to the actuation temperature of the water temperature contactor switch.
Observe the coolant temperature gauge in order to determine the temperature of the coolant when the actuation of the switch occurs. Compare the temperature on the gauge with the specifications for the water temperature contactor switch. The switch is actuated when the circuit across contacts (WTS-1) and (WTS-2) closes. The engine should shut down when the switch is actuated. This activates the protection system.
The actuation of the water temperature contactor switch may not occur when the temperature of the coolant is greater than the maximum value for the actuation temperature of the switch. Immediately reduce the load that is on the engine and remove the restriction to the air inlet. Allow the engine to run at idle until the temperature of the coolant returns to normal before you stop the engine.
The actual temperature of the coolant may not have been within the specifications of the water temperature contactor switch at the time of actuation. The switch is faulty and the switch needs to be replaced. Actuation might not occur when the temperature of the coolant is at the maximum. The switch is faulty and the switch needs to be replaced.

Have questions with 106871-2951?





Group cross 106871-2951 ZEXEL

Mitsubishi 

9 400 613 090 
ME060167 
INJECTION-PUMP ASSEMBLY
8DC82
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

 
ME060106 
INJECTION-PUMP ASSEMBLY
8DC11
 
ME060107 
INJECTION-PUMP ASSEMBLY
8DC11
 
ME060108 
INJECTION-PUMP ASSEMBLY
8DC11
 
 
INJECTION-PUMP ASSEMBLY
8DC9T2
106871-2951  
 
ME060464 
INJECTION-PUMP ASSEMBLY
8DC9T2
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

 
ME060445 
INJECTION-PUMP ASSEMBLY
8DC11
 
ME066808 
INJECTION-PUMP ASSEMBLY
8DC91
 
ME065606 
INJECTION-PUMP ASSEMBLY
8DC9
 
 
INJECTION-PUMP ASSEMBLY
8DC9T2
 
ME066809 
INJECTION-PUMP ASSEMBLY
8DC9T2
Back to top