106871-2921 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1068712921 me060106


 

Information injection-pump assembly

ZEXEL 106871-2921 1068712921
MITSUBISHI ME060106 me060106
106871-2921 INJECTION-PUMP ASSEMBLY
Rating:
43
Buy INJECTION-PUMP ASSEMBLY 106871-2921 zexel genuine, new aftermarket engine parts with delivery

Service parts 106871-2921 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106087-5820
3. GOVERNOR 105487-1590
4. SUPPLY PUMP 105207-1140
5. AUTOM. ADVANCE MECHANIS 105681-0171
6. COUPLING PLATE 105663-0390
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-7150
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 17.7(180)/21.6(220)
13. NOZZLE-HOLDER 105031-4500
14. NOZZLE 105015-6580
15. NOZZLE SET

Include in #1:

106871-2921 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 106871-2921 1068712921
MITSUBISHI ME060106 me060106


Zexel num
Bosch num
Firm num
Name
106871-2921 
 
ME060106  MITSUBISHI
INJECTION-PUMP ASSEMBLY
8DC11 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-2-7-3- 4-5-6-8
Pre-stroke mm   4.8 4.75 4.85
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cyl.1-2
deg.   45 44.5 45.5
Difference between angles 2
Cal 1-7
deg.   90 89.5 90.5
Difference between angles 3
Cal 1-3
deg.   135 134.5 135.5
Difference between angles 4
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 5
Cal 1-5
deg.   225 224.5 225.5
Difference between angles 6
Cal 1-6
deg.   270 269.5 270.5
Difference between angles 7
Cal 1-8
deg.   315 314.5 315.5
Injection quantity adjustment
Adjusting point   -
Rack position   10
Pump speed r/min   700 700 700
Each cylinder's injection qty mm3/st.   129 125.1 132.9
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   C
Rack position   6.1+-0.5
Pump speed r/min   225 225 225
Each cylinder's injection qty mm3/st.   20 17 23
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   129 128 130
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1(10)
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   131.7 126.3 137.1
Difference in delivery mm3/st.   10.8 10.8 10.8
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   E
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   160 140 180
Fixing the lever   *
Remarks
After startup boost setting
 
Timer adjustment
Pump speed r/min   -
Advance angle deg.   0 0 0
Remarks
Measure speed (beginning of operation).
 
Timer adjustment_02
Pump speed r/min   1100
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 106871-2921
N:Pump speed R:Rack position (mm) (1)Damper spring setting: DL (2)Tolerance for racks not indicated: +-0.05mm. (3)Excess fuel setting for starting: SXL
----------
DL=4.3-0.2mm SXL=10.8+-0.1mm
----------

Speed control lever angle

Test data 106871-2921
F:Full speed
----------

----------
a=21deg+-5deg

0000000901

Test data 106871-2921
F:Full load I:Idle (1)Stopper bolt setting
----------

----------
a=10deg+-5deg b=28deg+-3deg

Stop lever angle

Test data 106871-2921
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Stopper bolt setting (3)Rack position bb (4)Free (at shipping)
----------
aa=4-0.5mm bb=11.7mm
----------
a=43deg+7deg-5deg b=21.5deg+-5deg c=(10.5deg)

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=325r/min Ra=5.6+-0.1mm
----------

Timing setting

Test data 106871-2921
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(40deg)




Information:


Illustration 1 g00564355
7W-2743 Electronic Speed Switch (ESS)
(1) Push button for Overspeed Verification
(2) Reset button
(3) Overspeed indicator lamp
(4) Seal screw plug for adjusting the engine overspeed
(5) Seal screw plug for adjusting the crank terminate speed
(6) Seal screw plug for adjusting the oil step pressure speed setting The oil step speed calibration increases the oil step speed setting or the oil step speed calibration decreases the oil step speed setting. Refer to the Speed Specification Chart in order to find the oil step speed that is equal to the engine rpm when the engine is running.
Remove the lockwire and the seal from seal screw plug (6). Remove seal screw plug (6) from the access hole for the oil step speed adjusting screw.
Use a small screwdriver to lightly turn the oil step speed adjusting screw in the direction of the "MAX" arrow or the clockwise direction. Turn the screw twenty times. The oil step speed adjusting screw will vary the setting of a potentiometer that is inside of the ESS. The oil step speed adjusting screw will not cause damage to the potentiometer. Also, the screw can not be removed if the screw is turned in the wrong direction.
Connect a voltmeter with the positive lead at terminal (ESS-13) and the negative lead at (ESS-5). Use a 6V-7070 Digital Multimeter or a voltmeter with the same accuracy. Measure the voltage.
For a specific engine rating, find the engine rpm in the column for the oil step speed setting in the Speed Specification Chart. Run the engine at the rpm that is specified in the table.
While the engine is running, look into the hole for the adjustment of the oil step speed. A red indicator lamp should be lighted. A positive voltage should be observed on the multimeter 9 seconds after the indicator lamp is lighted. Turn the oil step speed adjusting screw clockwise until the indicator lamp turns off. The oil step speed setting is above the present rpm of the engine. Slowly turn the oil step speed adjusting screw counterclockwise until the indicator lamp is lighted. After a 9 second delay, a positive voltage should be observed on the multimeter. This position is the correct setting for the oil step speed.
Install seal screw plug (6) in the access hole for the oil step speed adjusting screw. Tighten the screw to a torque of 0.20 0.03 N m (1.8 .3 lb in). Install the lockwire and the seal if the overspeed calibration and the crank terminate speed calibration are also complete.

Have questions with 106871-2921?





Group cross 106871-2921 ZEXEL

Mitsubishi 

9 400 613 090 
ME060167 
INJECTION-PUMP ASSEMBLY
8DC82
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

106871-2921  
 
ME060106 
INJECTION-PUMP ASSEMBLY
8DC11
 
ME060107 
INJECTION-PUMP ASSEMBLY
8DC11
 
ME060108 
INJECTION-PUMP ASSEMBLY
8DC11
 
 
INJECTION-PUMP ASSEMBLY
8DC9T2
 
ME060464 
INJECTION-PUMP ASSEMBLY
8DC9T2
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

 
ME060445 
INJECTION-PUMP ASSEMBLY
8DC11
 
ME066808 
INJECTION-PUMP ASSEMBLY
8DC91
 
ME065606 
INJECTION-PUMP ASSEMBLY
8DC9
 
 
INJECTION-PUMP ASSEMBLY
8DC9T2
 
ME066809 
INJECTION-PUMP ASSEMBLY
8DC9T2
Back to top