106861-2620 ZEXEL 9 400 612 507 BOSCH INJECTION-PUMP ASSEMBLY 9400612507 1068612620


 

Information injection-pump assembly

BOSCH 9 400 612 507 9400612507
ZEXEL 106861-2620 1068612620
106861-2620 INJECTION-PUMP ASSEMBLY
Rating:
27
Buy INJECTION-PUMP ASSEMBLY 106861-2620 zexel genuine, new aftermarket engine parts with delivery

Service parts 106861-2620 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106086-5720
3. GOVERNOR 105407-7980
4. SUPPLY PUMP 105237-0280
5. AUTOM. ADVANCE MECHANIS 105636-0620
6. COUPLING PLATE 105663-0390
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-4972
11. Nozzle and Holder ME066034
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105030-4990
14. NOZZLE 105015-4580
15. NOZZLE SET

Include in #1:

106861-2620 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 612 507 9400612507
ZEXEL 106861-2620 1068612620


Zexel num
Bosch num
Firm num
Name
106861-2620 
106861-2621 
9 400 612 507 
   
INJECTION-PUMP ASSEMBLY
* K 14CD PE8P PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131424-8020
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-2-7-3- 4-5-6-8
Pre-stroke mm   4.8 4.75 4.85
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cyl.1-2
deg.   45 44.5 45.5
Difference between angles 2
Cal 1-7
deg.   90 89.5 90.5
Difference between angles 3
Cal 1-3
deg.   135 134.5 135.5
Difference between angles 4
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 5
Cal 1-5
deg.   225 224.5 225.5
Difference between angles 6
Cal 1-6
deg.   270 269.5 270.5
Difference between angles 7
Cal 1-8
deg.   315 314.5 315.5
Injection quantity adjustment
Adjusting point   A
Rack position   10.7
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   133.5 130.5 136.5
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   4.9+-0.5
Pump speed r/min   275 275 275
Average injection quantity mm3/st.   15.5 12.9 18.1
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Injection quantity adjustment_03
Adjusting point   D
Rack position   10.9++
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   135 135 145
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   (N1+50)- -
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   N1
Advance angle deg.   0.5
Remarks
Measure the actual speed.
 
Timer adjustment_03
Pump speed r/min   900
Remarks
Measure the actual advance angle.
 
Timer adjustment_04
Pump speed r/min   -
Advance angle deg.   3 3 3
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 106861-2620
N:Pump speed R:Rack position (mm) (1)Notch fixed: K (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT (4)Rack difference between N = N1 and N = N2 (5)Set idle sub-spring
----------
K=9 N1=850r/min N2=500r/min
----------

Speed control lever angle

Test data 106861-2620
F:Full speed I:Idle (1)Set the pump speed at aa (2)Set the pump speed at bb. (3)Stopper bolt setting
----------
aa=910r/min bb=755r/min
----------
a=(2deg)+-5deg b=(30deg)+-5deg c=(7deg)+-5deg

Stop lever angle

Test data 106861-2620
N:Pump normal S:Stop the pump. (1)Right front (2)Right rear (3)Normal
----------

----------
a=19deg+-5deg b=46deg+-5deg c=28deg+-5deg d=53deg+-5deg

Timing setting

Test data 106861-2620
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(40deg)




Information:

Until recently, engine maintenance and repair management involved changing the oil when it was convenient and repairing the engine when it was damaged. This seemed to be the accepted way of managing a maintenance operation.However, due to a variety of circumstances, increasing competition have caused users to look for ways to prolong equipment life and lower operating costs so that they could be competitive.To assist Caterpillar engine users in prolonging engine life and reducing operating costs, the

Have questions with 106861-2620?





Group cross 106861-2620 ZEXEL

9 400 619 666 
 
INJECTION-PUMP ASSEMBLY
F 01G 09U 09G 
 
INJECTION-PUMP ASSEMBLY
8DC9T

Mitsubishi 

9 400 618 001 
ME098786 
INJECTION-PUMP ASSEMBLY
8DC9T
9 400 618 002 
ME098787 
INJECTION-PUMP ASSEMBLY
8DC9T
106861-2620  

106861-2621 
9 400 612 507 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

F 019 Z20 227 
ME440739 
INJECTION-PUMP ASSEMBLY
8DC9T
9 400 612 674 
ME441179 
INJECTION-PUMP ASSEMBLY
8DC9TL
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

F 019 Z20 228 
ME442511 
INJECTION-PUMP ASSEMBLY
8DC9TL
9 400 618 003 
ME441199 
INJECTION-PUMP ASSEMBLY
8DC9T
9 400 618 004 
ME441817 
INJECTION-PUMP ASSEMBLY
8DC9T
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

F 019 Z20 229 
ME442512 
INJECTION-PUMP ASSEMBLY
8DC9T
F 019 Z10 232 
ME442876 
INJECTION-PUMP ASSEMBLY
8DC9TL
Back to top