106861-2311 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1068612311 me065614


 

Information injection-pump assembly

ZEXEL 106861-2311 1068612311
MITSUBISHI ME065614 me065614
106861-2311 INJECTION-PUMP ASSEMBLY
Rating:
58
Buy INJECTION-PUMP ASSEMBLY 106861-2311 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
106861-2311 
 
ME065614  MITSUBISHI
INJECTION-PUMP ASSEMBLY
8DC9T0 * K




Information:

Storage Procedure
When a generator is in storage for any length of time, moisture condenses in the windings. Minimize the condensation by use of a dry storage space and space heaters. Refer to step 2 belowIf a brush-type generator (SRCR) is to be in storage for a year or more, lift the brushes off the slip ring to prevent damage to the slip ring by chemical action.After Storage
Test the main stator windings with a megohmmeter in the following situations: 1. Before initial startup of generator set.2. Every 3 months* if generator is operating in a humid environment.3. If generator has not been run under load for 3 months* or more.*This is a guideline only. It may be necessary to megger more frequently if environment is extremely humid, salty or if the last megger test was close to 1 megohm.The megohmmeter test is described in Service Manuals SENR2180 or SENR7968. A reading of 1 meghom or less indicates that the winding has absorbed too much moisture.To Remove Moisture
To remove moisture caused by high humidity, use one of the following methods to make the generator dry:1. Energize space heaters in generator if so equipped.2. Put the generator in an oven at a temperature of not more than 85°C (185°F) for four hours.
If an oven is used for drying, use a forced air type rather than a radiant type. Radiant ovens can cause localized overheating.
3. Space heaters of the same type used in marine applications, can be installed on generators. (See the Parts Book.) These heaters heat the windings to remove moisture and should be connected at all times in high humidity conditions whenever the generator is not running.4. Use a canvas enclosure around the generator and heating lamps to increase the temperature. Make an opening in the top for release of moisture.5. Send a low voltage current through the windings to increase the temperature of the windings. Do not exceed 85°C (185°F).If the megohmmeter test reads under 1 megohm after the drying or if it goes below 1 megohm shortly after drying, contact your Caterpillar dealer. The insulation has deteriorated and should be reconditioned.

Have questions with 106861-2311?





Group cross 106861-2311 ZEXEL

Mitsubishi 

 
 
INJECTION-PUMP ASSEMBLY
8DC9T0
9 400 617 979 
ME065613 
INJECTION-PUMP ASSEMBLY
8DC9T0
 
 
INJECTION-PUMP ASSEMBLY
8DC9T0
106861-2311  
 
ME065614 
INJECTION-PUMP ASSEMBLY
8DC9T0
 
 
INJECTION-PUMP ASSEMBLY
8DC91T0
9 400 617 980 
ME065878 
INJECTION-PUMP ASSEMBLY
8DC91T0
 
 
INJECTION-PUMP ASSEMBLY
8DC91T0
9 400 617 981 
ME065879 
INJECTION-PUMP ASSEMBLY
8DC91T0
 
 
INJECTION-PUMP ASSEMBLY
8DC9T0
9 400 617 982 
ME065880 
INJECTION-PUMP ASSEMBLY
8DC9T0
 
 
INJECTION-PUMP ASSEMBLY
8DC9T0
 
 
INJECTION-PUMP ASSEMBLY
8DC9T0
 
ME065615 
INJECTION-PUMP ASSEMBLY
8DC9T0
 
 
INJECTION-PUMP ASSEMBLY
8DC9T
9 400 617 983 
ME098529 
INJECTION-PUMP ASSEMBLY
8DC9T
 
 
INJECTION-PUMP ASSEMBLY
8DC9T
9 400 617 984 
ME098530 
INJECTION-PUMP ASSEMBLY
8DC9T
 
 
INJECTION-PUMP ASSEMBLY
8DC9T0
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

 
ME065935 
INJECTION-PUMP ASSEMBLY
8DC9T0
Back to top