106693-1780 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1066931780 1156024540


 

Information injection-pump assembly

ZEXEL 106693-1780 1066931780
ISUZU 1156024540 1156024540
106693-1780 INJECTION-PUMP ASSEMBLY
Rating:
21
Buy INJECTION-PUMP ASSEMBLY 106693-1780 zexel genuine, new aftermarket engine parts with delivery

Service parts 106693-1780 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106069-5590
3. GOVERNOR 105488-1160
4. SUPPLY PUMP 105237-1430
5. AUTOM. ADVANCE MECHANIS 105636-1570
6. COUPLING PLATE 105663-0250
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-6991
11. Nozzle and Holder 1-15300-159-1
12. Open Pre:MPa(Kqf/cm2) 19.6(200)
13. NOZZLE-HOLDER 105030-4271
14. NOZZLE 105015-6660
15. NOZZLE SET

Include in #1:

106693-1780 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106693-1780 
106693-1781 
 
1156024540  ISUZU
INJECTION-PUMP ASSEMBLY
6RB1T * K




Information:

Center Bushing Check new bushings using the table below. Commutator and Drive End Bushing Specifications*I.D. of bushing ... 0.6693 to 0.6704 in.(17.000 to 17.028 mm)Oil clearance** ... 0.0036 to 0.0070 in.(0.091 to 0.178 mm)Maximum clearance** ... 0.016 in.(0.41 mm)Bushing depth ... 0.008 to 0.022 in.(0.20 to 0.56 mm)*Reaming may be necessary after installation. Center Bushing SpecificationsI.D. of bushing ... 1.182 to 1.184 in.(30.02 to 30.07 mm)Maximum clearance** ... 0.0236 in.(0.599 mm)Bushing depth ... 0.017 to 0.032 in.(0.43 to 0.81 mm)**The clearance is the difference between the shaft and the I.D. of the bushing.Armature
Check armature for straightness. Runout should not exceed 0.006 inch (0.15 mm). Maximum commutator runout is 0.016 inch (0.41 mm). If necessary, turn commutator and undercut insulation to 1/32-inch (0.794 mm). Undercut should never be less than 0.008 inch (0.20 mm) Commutator O.D. must be 1.77 inches (45.0 mm) or more. Clean copper dust from between the segments.Check armature for opens, shorts and grounds. Burned edge of commutator indicates an open circuit. Short Circuit TestPlace the armature in a growler and hold a hacksaw blade above each slot while slowly rotating the armature. If a coil is shorted, the blade will be attracted to and repelled from the slot.A short circuit most often occurs because of copper dust or filings between two commutator segments. A short of this nature can be corrected by removal of such material.
Fig. 22-Armature Ground TestWith the ohmmeter set to read on its highest scale, place one test lead on the commutator and the other lead on the armature core or shaft (Fig. 22). If the test meter indicator swings towards zero, the armature is grounded. Replace armature.
Fig. 23-Open Circuit TestWith the ohmmeter set to read on its lowest scale, place one test lead on the commutator segment and the other test lead on an adjacent segment (Fig. 23). Repeat this operation for all segments by moving one lead at a time. If the test meter indicator does not swing to zero and remains stationary, the armature coil between these two segements is open. Replace armature.Burned commutator segments are usually an indication of an open circuited coil.Overrunning Clutch and Pinion
Do not immerse the overrunning clutch and pinion 4, Fig. 21 in a cleaning solvent. The unit has been prelubricated and solvent will wash lubricant away. It may be cleaned with a cloth moistened with a cleaning solvent and wiped dry.Rotate the pinion. Pinion gear should rotate smoothly (but not necessarily easily) in one direction, and should not rotate in the opposite direction.If the pinion gear does not rotate smoothly, or if it is worn, chipped, or burred, it should be replaced.Field Windings and Shunt Windings
Grounded Circuit Test (Fig. 24)
Fig. 24-Grounded Circuit TestRemove the screw and hang the eyelet terminal in the air. Using an ohmmeter set to read on its highest scale, place one test lead on the copper terminal bolt and the other lead on a clean spot of the field frame (Fig. 24). If the ohmmeter

Have questions with 106693-1780?





Group cross 106693-1780 ZEXEL

Isuzu 

 
1156021002 
INJECTION-PUMP ASSEMBLY
6RB1T
 
1156021003 
INJECTION-PUMP ASSEMBLY
6RB1T
 
1156021550 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156021551 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156020810 
INJECTION-PUMP ASSEMBLY
6RB1
9 400 610 178 
1156023550 
INJECTION-PUMP ASSEMBLY
6RB1T
 
1156023760 
INJECTION-PUMP ASSEMBLY
6SD1TC3
 
1156023762 
INJECTION-PUMP ASSEMBLY
6SD1-TC3
 
1156023763 
INJECTION-PUMP ASSEMBLY
6SD1-TC3
 
1156023764 
INJECTION-PUMP ASSEMBLY
6SD1-TC3
9 400 617 912 
1156023765 
INJECTION-PUMP ASSEMBLY
6SD1-TC3
 
1156024380 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156024381 
INJECTION-PUMP ASSEMBLY
6RB1
9 400 617 913 
1156024382 
INJECTION-PUMP ASSEMBLY
6RB1
9 400 619 609 
1156024390 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156024391 
INJECTION-PUMP ASSEMBLY
6RB1
9 400 617 914 
1156024392 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156024400 
INJECTION-PUMP ASSEMBLY
6RB1
9 400 619 735 
1156024401 
INJECTION-PUMP ASSEMBLY
6RB1
9 400 619 735 
1156024403 
INJECTION-PUMP ASSEMBLY
6RB1
F 01G 09U 096 
1156024402 
INJECTION-PUMP ASSEMBLY
6RB1
106693-1780  

106693-1781 
 
1156024540 
INJECTION-PUMP ASSEMBLY
6RB1T
 
1156024541 
INJECTION-PUMP ASSEMBLY
6RB1-T
 
1156024542 
INJECTION-PUMP ASSEMBLY
6RB1-T
 
1156024560 
INJECTION-PUMP ASSEMBLY
6RB1T
 
1156024561 
INJECTION-PUMP ASSEMBLY
6RB1-T
Back to top