106692-9450 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1066929450


 

Information injection-pump assembly

ZEXEL 106692-9450 1066929450
106692-9450 INJECTION-PUMP ASSEMBLY
Rating:
53
Buy INJECTION-PUMP ASSEMBLY 106692-9450 zexel genuine, new aftermarket engine parts with delivery

Service parts 106692-9450 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106069-7440
3. GOVERNOR 105952-1750
4. SUPPLY PUMP 105217-1490
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105663-0360
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105111-4060
11. Nozzle and Holder 6151-11-3101
12. Open Pre:MPa(Kqf/cm2) 24.5{250}
13. NOZZLE-HOLDER 105041-7040
14. NOZZLE 105015-5950
15. NOZZLE SET

Include in #1:

106692-9450 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106692-9450 
 
   
INJECTION-PUMP ASSEMBLY




Information:

Introduction
This Special Instruction provides information to reset Diesel Particulate Filter (DPF) soot load on certain XQ60 rental generator sets.Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.Safety Section
Do not perform any procedure in this Special Instruction until you have read this Special Instruction and you understand this information. Use only proper tools and observe all precautions that pertain to the use of those tools. Failure to follow these procedures can result in personal injury. The following procedures should be observed.Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.A person must be alert to potential hazards. This person must also have the necessary training, skills, and tools to perform these functions properly.Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance of a potential hazard.Therefore, the warnings in this publication and the warnings that are on the product are not all inclusive. Avoid using a tool, a procedure, a work method, or operating technique that is not recommended by Caterpillar.Ensure that the product will not be damaged or the product will be made unsafe by the operation, lubrication, maintenance, or the repair procedures.
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Failure to follow all safety guidelines prescribed in this document and by governing authorities and regulatory agencies may result in severe injury or death of personnel or machine damage.
Reset Procedure for DPF Soot Load
Perform the following procedure to reset DPF soot load:
Turn the generator set battery disconnect to ON position.
Verify power to Electronic Modular Control Panel (EMCP).
Connect Cat® Electronic Technician (Cat ET) service tool.
Connect to Cat ET - Configuration EMCP Controller.
Update "RO#2" on EMCP from "Eng Start Initiated" to "Auto Mode".
Change the generator set to auto mode. Changing the generator set to auto mode applies power to engine Electronic Control Module (ECM).
Verify whether the active code in Cat ET is "3719-0 - High DPF Soot Load".
Illustration 1 g06574660
Electronic Modular Control Panel
Illustration 2 g06574661
Engine Electronic Control Module
Check whether the parameters shown in Illustration 1 and Illustration 2 are set in "EMCP" and "Engine ECM" configurations.
Illustration 3 g06574662
Perform DPF soot load reset by navigating "Component Replacement Resets".
Verify DPF Soot Load value in "Engine Status" screen.
Verify the active codes.
Stop the unit in EMCP.
Update "RO#2" from "Auto Mode" to "Eng Start Initiated".
Check whether the unit is set to run at idle speed in "EMCP".
Run the unit and check whether "low idle speed" is 1200 rpm. Refer to Illustration 3.
Manually

Have questions with 106692-9450?





Group cross 106692-9450 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY

Yanmar 

9 400 613 274 
12662451020 
INJECTION-PUMP ASSEMBLY
6HAL2-DT
 
 
INJECTION-PUMP ASSEMBLY

Yanmar 

9 400 611 669 
12662051010 
INJECTION-PUMP ASSEMBLY
6HAL2
 
 
INJECTION-PUMP ASSEMBLY

Yanmar 

9 400 611 287 
12662051020 
INJECTION-PUMP ASSEMBLY
6HAL2
9 400 619 975 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

 
6151711750 
INJECTION-PUMP ASSEMBLY
S6D125
 
6151711751 
INJECTION-PUMP ASSEMBLY
S6D125
9 400 617 891 
6151711752 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

 
6151721810 
INJECTION-PUMP ASSEMBLY
S6D125
9 400 617 892 
6151721811 
INJECTION-PUMP ASSEMBLY
S6D125
106692-9450  
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

 
6151711570 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY
S6D125

Komatsu 

9 400 617 893 
6151711571 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

 
6151721820 
INJECTION-PUMP ASSEMBLY
S6D125
9 400 617 894 
6151721821 
INJECTION-PUMP ASSEMBLY
S6D125
 
6151721850 
INJECTION-PUMP ASSEMBLY
S6D125
 
6151721851 
INJECTION-PUMP ASSEMBLY
S6D125
9 400 617 895 
6151721852 
INJECTION-PUMP ASSEMBLY
S6D125
9 400 611 910 
 
INJECTION-PUMP ASSEMBLY
S6D125

Komatsu 

9 400 617 896 
6151721910 
INJECTION-PUMP ASSEMBLY
S6D125
 
6151711572 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 617 897 
6151711573 
INJECTION-PUMP ASSEMBLY
S6D125
Back to top