106692-4701 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1066924701


 

Information injection-pump assembly

ZEXEL 106692-4701 1066924701
106692-4701 INJECTION-PUMP ASSEMBLY
Rating:
76
Buy INJECTION-PUMP ASSEMBLY 106692-4701 zexel genuine, new aftermarket engine parts with delivery

Service parts 106692-4701 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106069-5420
3. GOVERNOR 105407-3631
4. SUPPLY PUMP 105217-1480
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105663-0360
7. COUPLING PLATE 156636-6220
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105111-4060
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 24.5(250)
13. NOZZLE-HOLDER 105041-7040
14. NOZZLE 105015-5950
15. NOZZLE SET

Include in #1:

106692-4701 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106692-4701 
 
   
INJECTION-PUMP ASSEMBLY




Information:

General Contamination Control Recommendations or Practices
Maintaining a low contamination level can reduce down time and can control the maintenance cost of the engine. The productive life as well as the reliability of components and fluid systems is often increased as a result of proper contamination control practices.The following are general guidelines for controlling contaminants.
Refer to the Recommendations for Fuel Systems in this chapter for recommended fuel cleanliness levels and guidelines.
Refer to the engine Operation and Maintenance Manual for the required maintenance for all engine fluids.
When you add oil to an engine, use engine oil filters of 12 microns absolute efficiency. Ensure that the oil temperature is 20° C (68° F) or higher.
Perform scheduled S O S Services Oil Analysis for contamination in order to maintain the recommended ISO cleanliness level of fill and machine fluids. Refer to the S O S Oil Analysis section in this Special Publication. The particle count analysis can be performed by your Cat dealer. Particle count can be conducted during the scheduled S O S Services Oil Analysis for the compartment. Extra oil samples are not required for the particle count sampling.
Use only coolants that are recommended by Cat for your machine. Follow the recommended maintenance procedure for the cooling system in the Operation and Maintenance Manual for your machine.
Maintain the engine air filters and air intake system to avoid unwanted contaminant ingression.
Follow contamination control practices for the shop area, component/machine disassembly areas, parts, shop tools, test setups, test areas, storage areas and waste collection areas. Keep components clean during inspection, assembly, testing, and filling engines with clean fluids. Good practices will enhance component life and reduce downtime associated with contaminants. Your Cat dealer can provide details on proper contamination processes and practices.
Follow contamination control practices for the workplace and for the worksite. Maintaining clean oil fill fluids saves time and effort and ensures that fill fluids are at the proper cleanliness levels.
Use properly designed and maintained bulk storage fluids tanks.
Protect the fluids storage tanks from dirt and water entry by using 4 µm or less absolute efficiency breathers with the ability to remove water.
Keep the areas around the tanks filler necks clean of debris and water.
Drain the storage tanks from water and sediments frequently. The draining schedule depends on use of proper inlet and outlet filters, the use of 4 µm breathers with the ability to remove water, and following recommended contamination control practices. Based on the contamination control program followed, and/or on the fuel supplier recommendations, the storage tank draining schedule may be as frequent as daily until no water is present, and then can be extended to longer periods.
Install and maintain a properly designed and grounded filtration system. Filtration should include at the entry and at the dispensing point. Continuous bulk filtration may be required to ensure that dispensed oils meet the cleanliness target.
Cover, protect, and ensure cleanliness of all connection hoses, fittings, and dispensing nozzles.Note: Bulk fuel filtration units are available through your Cat dealer. Proper maintenance practices of

Have questions with 106692-4701?





Group cross 106692-4701 ZEXEL

106692-4701  
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 617 855 
6151711141 
INJECTION-PUMP ASSEMBLY
S6D125
9 400 610 275 
6211711313 
INJECTION-PUMP ASSEMBLY
S6D140
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

 
6151711161 
INJECTION-PUMP ASSEMBLY
S6D125
 
6210711130 
INJECTION-PUMP ASSEMBLY
6D140
 
6162731581 
INJECTION-PUMP ASSEMBLY
S6D170
9 400 610 237 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 610 367 
6162731582 
INJECTION-PUMP ASSEMBLY
S6D170
9 400 610 085 
 
INJECTION-PUMP ASSEMBLY
9 400 610 238 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 617 856 
6151711450 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY
S6D140
 
6211711351 
INJECTION-PUMP ASSEMBLY
S6D140
 
 
INJECTION-PUMP ASSEMBLY
S6D140
9 400 617 857 
6211711322 
INJECTION-PUMP ASSEMBLY
S6D140
9 400 617 858 
6151711620 
INJECTION-PUMP ASSEMBLY
S6D125
Back to top