106692-4533 ZEXEL 9 400 617 847 BOSCH INJECTION-PUMP ASSEMBLY 9400617847 1066924533 6162731742


 

Information injection-pump assembly

BOSCH 9 400 617 847 9400617847
ZEXEL 106692-4533 1066924533
KOMATSU 6162731742 6162731742
106692-4533 INJECTION-PUMP ASSEMBLY
Rating:
41
Buy INJECTION-PUMP ASSEMBLY 106692-4533 zexel genuine, new aftermarket engine parts with delivery

Service parts 106692-4533 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106069-8031
3. GOVERNOR 105448-9652
4. SUPPLY PUMP 105207-1340
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105111-4102
11. Nozzle and Holder 6162-13-3503
12. Open Pre:MPa(Kqf/cm2) 26.0{265}
13. NOZZLE-HOLDER 105041-7111
14. NOZZLE 105015-6160
15. NOZZLE SET

Include in #1:

106692-4533 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106692-4533 
106692-9070 
9 400 617 847 
6162731742  KOMATSU
INJECTION-PUMP ASSEMBLY
SA6D170 K




Information:

Additional Parts Needed for Installation
Fluid Property Sensor Mounting Bracket
A mounting bracket must be fabricated to support the Fluid Property Sensor. Since the kit can be used on a large range of engines in both stationary and machine applications, no universal mounting bracket design is possible. A bracket must be field fabricated to allow mounting of the sensor to a structural component of the machine. Leave room for electrical connection and room at each end for Engine Lubricating Oil line connections.Fittings and Adapters
Due to the large range of engines that this system may be used on, a list of all Engine Lubrication Oil line fittings, sizes, styles, and adapters are not possible. As a starting point, the inlet and outlet of the sensor adapter is a 37 degree Flare for 1" oil lines. This must be adapted to the correct size oil line tubing required for each engine. It is likely that the supply and return fuel lines will be of different sizes. It is recommended that the oil line tubing be new and in good condition. The tubing MUST be clean inside. Any small particles that are carried from the inlet hose through the transducer from the system and dislodge the particles. If hoses are equipped with O-ring fittings, the O-rings must be new.Wiring Diagram
Note: During Installation, it is important to protect wiring in key locations. Key locations are any area where the wiring could be nicked or cut and come in contact with the chassis. Avoid installation practices where there could be excessive flexing, chafing, or cutting of the wiring.
Illustration 1 g06137996
Fluid Property Sensor Wiring Schematic
Installation
Machine Preparation
Move the machine to a smooth, level location, and away from other working machines and personnel.
Lower the implements to the ground.
Stop the engine.
Engage the parking brake for the machine.
Place the disconnect switch in the OFF position.
Follow all LOTO instructions for the machine.Installation of the Fluid Property Sensor
The Fluid Property Sensor must be located on a field fabricated bracket in a location of the installer's choice. When selecting a mounting location, the installer must mount the sensor in an area off the engine to reduce vibration of the sensor as well as accessibility of sensor and electrical connection. Electrical connections should avoid sharp bends at connectors, sharp edges, and chafing surfaces. Harnesses should be supported at no less than 30.48 cm (12 inch) intervals. The Fluid Property Sensor must be installed with the orifice opening in the upright position as shown in Illustration 2.
Illustration 2 g06138010
Fluid Property Sensor Installation
(A) Oil Pump
(B) Oil Filter
(C) Engine Oil Gallery
(D) Isolation Valve
(E) Oil Flow
(F) Fluid Property Sensor Orientation
(G) Oil Reservoir
(H) Oil Strainer
(I) Engine Oil SumpInstallation of the Electrical Harnesses
Note: During installation, it is important to protect wiring in key locations. Key locations are any area where the wiring could be nicked or cut and come in contact with the chassis. Avoid installation practices where there could be excessive flexing, chafing, or cutting of the wiring.
Install the 514-3811 Instl GP-Field (Fluid Property Harness) on Fluid Property Sensor.
Route harness back

Have questions with 106692-4533?





Group cross 106692-4533 ZEXEL

Komatsu 

 
6151711923 
INJECTION-PUMP ASSEMBLY
S6D125
 
6151711171 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY
SA6D170
 
6162731740 
INJECTION-PUMP ASSEMBLY
SA6D170
 
6162731741 
INJECTION-PUMP ASSEMBLY
SA6D170
106692-4533  

106692-9070 
9 400 617 847 
6162731742 
INJECTION-PUMP ASSEMBLY
SA6D170
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

 
6151711651 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY
SA6D170
 
6162731390 
INJECTION-PUMP ASSEMBLY
SA6D170
9 400 617 848 
6162731391 
INJECTION-PUMP ASSEMBLY
SA6D170
 
6151711912 
INJECTION-PUMP ASSEMBLY
S6D125
 
6162731730 
INJECTION-PUMP ASSEMBLY
S6D170
 
6162731731 
INJECTION-PUMP ASSEMBLY
S6D170
9 400 617 849 
6162731732 
INJECTION-PUMP ASSEMBLY
S6D170
 
6151711661 
INJECTION-PUMP ASSEMBLY
S6D125
9 400 610 235 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 617 850 
6151711410 
INJECTION-PUMP ASSEMBLY
S6D125
Back to top