106692-4110 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1066924110


 

Information injection-pump assembly

ZEXEL 106692-4110 1066924110
106692-4110 INJECTION-PUMP ASSEMBLY
Rating:
40
Buy INJECTION-PUMP ASSEMBLY 106692-4110 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

ZEXEL 106692-4110 1066924110


Zexel num
Bosch num
Firm num
Name
106692-4110 
106692-4990 
 
  KOMATSU
INJECTION-PUMP ASSEMBLY
S6D170 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8130
Bosch type code   EFEP215A
Nozzle   105780-0050
Bosch type code   DN6TD119NP1T
Nozzle holder   105780-2090
Bosch type code   EFEP215
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   2.4 2.35 2.45
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   13.3
Pump speed r/min   900 900 900
Each cylinder's injection qty mm3/st.   409 404 414
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   5.4+-0.5
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   40 35 45
Max. variation between cylinders %   0 -10 10
Fixing the rack   *

Test data Ex:

Governor adjustment

Test data 106692-4110
N:Pump speed R:Rack position (mm) (1)Notch fixed: K (2)RACK LIMIT: RAL (3)Idle sub spring setting: L1.
----------
K=17 RAL=14.8+0.2mm L1=5.3-0.5mm
----------

Speed control lever angle

Test data 106692-4110
F:Full speed I:Idle (1)Set the pump speed at aa. ( At delivery ) (2)Pump speed = bb (3)Stopper bolt setting
----------
aa=900r/min bb=750r/min
----------
a=(9deg)+-5deg b=(2deg)+-5deg c=(36deg)+-5deg

Stop lever angle

Test data 106692-4110
F:Full load I:Idle S:Stop
----------

----------
a=26.5deg+-5deg b=(35deg)+-5deg c=53deg+-5deg

Timing setting

Test data 106692-4110
(1)Pump vertical direction (2)Position of spline gear's aligning mark at No 1 cylinder's beginning of injection (key position) (3)- (4)-
----------

----------
a=(130deg)




Information:

Procedure
Note: Prior to performing the analysis with the APC, be sure to read and understand all the interferences listed in the "Interferences Inherent In the Fuel Sample" section of this document. Ensure that all precautions have been taken to minimize the affect of skewed results due to improper sampling, handling, or preparation.
Obtain the fuel sample to be analyzed in an appropriate sample bottle as described in the "Fuel Sample Preparation" section. Manually or mechanically shake the sample vigorously for 30 seconds. When manually shaking a sample, ensure thorough mixing of the sample by turning the bottle so that the lid is facing downward. Shake by moving the wrist and/or forearm up and down as rapidly as is comfortable for the 30 seconds.Note: Degassing samples can be accomplished with either the use of an ultrasonic bath or with the use of a vacuum pump.
Immediately degas the sample, by partially opening the lid to the bottle and placing the sample upright in the degassing unit. Perform only one of the degassing methods. An ultrasonic bath is the best method for degassing a sample. An ultrasonic bath takes the least amount of time minimizing the impact of particle settling.Note: The purpose of partially unscrewing or opening the lid is to promote quick degassing of the sample. Air bubbles to remaining near the surface of the sample following the degassing process are acceptable.
Illustration 5 g01741117
If an ultrasonic bath is unavailable, an alternative method of degassing the sample is with the use of a 1U-5718 Oil Sampling Vacuum Pump. Ensure the 1U-5718 Oil Sampling Vacuum Pump is clean before beginning the degas process.Note: Rubber is to be placed over the hole of the tubing for the pump to develop and hold the required vacuum.
With the sample to be analyzed in the sample bottle, thread the bottle into the bottom of the 1U-5718 Oil Sampling Vacuum Group. Operate the pump to create a vacuum. Maintain the vacuum until all air bubbles have risen to the surface of the sample and dissipated.
If an ultrasonic bath or a vacuum pump is not available, the sample can degas naturally. Degas the sample by setting the sample on a flat surface and leaving the sample undisturbed. If the APC performs a flushing cycle, let the sample sit for 15 seconds. If the APC does not perform a flushing cycle, such as the 293-8413 HYDAC Contamination Monitor Group or the 383-4255 HYDAC Contamination Monitor Group, let the sample sit for 30 seconds. Proceed to the "Sample Processing" section.Sample Processing
Remove the lid from the sample bottle. Immediately begin the processing of the sample on the APC that has been prepared according to the "Fuel Sample Preparation" section.Note: If more than 45 seconds elapse after the shaking of the sample, the procedure shall be restarted with shaking of the sample in "Fuel Sample Preparation" section. Shaking the sample ensures that suspended particles do not settle to the bottom of the sample, causing inaccurate particle count results.
Obtain the particle count results

Have questions with 106692-4110?





Group cross 106692-4110 ZEXEL

Komatsu 

 
6151711721 
INJECTION-PUMP ASSEMBLY
S6D125
9 400 617 824 
6151711723 
INJECTION-PUMP ASSEMBLY
S6D125
106692-4110  

106692-4990 
 
 
INJECTION-PUMP ASSEMBLY
S6D170
 
6162731212 
INJECTION-PUMP ASSEMBLY
S6D170
 
6162731213 
INJECTION-PUMP ASSEMBLY
S6D170
9 400 617 825 
6162731214 
INJECTION-PUMP ASSEMBLY
S6D170
 
 
INJECTION-PUMP ASSEMBLY
SA6D170
 
6162731251 
INJECTION-PUMP ASSEMBLY
SA6D170
 
6162731252 
INJECTION-PUMP ASSEMBLY
SA6D170
9 400 610 230 
6162731253 
INJECTION-PUMP ASSEMBLY
SA6D170
 
6151711930 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY
S6D125
F 019 Z10 044 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 617 826 
6151711932 
INJECTION-PUMP ASSEMBLY
S6D125
 
6151711950 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 617 827 
6151711952 
INJECTION-PUMP ASSEMBLY
S6D125
9 400 617 828 
6151711311 
INJECTION-PUMP ASSEMBLY
S6D125
9 400 617 829 
6151711321 
INJECTION-PUMP ASSEMBLY
S6D125
 
6151711360 
INJECTION-PUMP ASSEMBLY
S6D125
 
6151711361 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 617 830 
6151711832 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 617 831 
6151711812 
INJECTION-PUMP ASSEMBLY
S6D125
Back to top