106692-1190 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1066921190 1156018400


 

Information injection-pump assembly

ZEXEL 106692-1190 1066921190
ISUZU 1156018400 1156018400
106692-1190 INJECTION-PUMP ASSEMBLY
Rating:
18
Buy INJECTION-PUMP ASSEMBLY 106692-1190 zexel genuine, new aftermarket engine parts with delivery

Service parts 106692-1190 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106069-1341
3. GOVERNOR 105407-2920
4. SUPPLY PUMP 105237-1500
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105662-0350
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-4891
11. Nozzle and Holder 1-15300-041-1
12. Open Pre:MPa(Kqf/cm2) 22.1(225)
13. NOZZLE-HOLDER 105031-4171
14. NOZZLE 105015-3520
15. NOZZLE SET

Include in #1:

106692-1190 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106692-1190 
 
1156018400  ISUZU
INJECTION-PUMP ASSEMBLY
6RB1 * K 14CA PE6P,6PD PE




Information:


Illustration 4 g01341045
(6) Temperature Sensor
(7) Pressure Sensor
Mount the 271-7350 Warning Indicator Module Gp in a place that is easy to view. Ensure that the ambient temperature is below 45 °C (113 °F), and ensure that the Warning Indicator Module is not directly exposed to high pressure steam cleaning, solvents, the battery off gas, or electrical discharge. Note: The LED display panel may be installed in the cab of the vehicle.
Illustration 5 g01341118
(8) LED display panel
(9) ECM Installation for the Wiring Harness
The 274-7578 Monitor Electronic Control Module is provided with a 307-5521 Wire Harness.
Connect the 70 pin AMP to the ECM using a 160-7690 Connector Plug As. Tighten the Connector Screw for the ECM to 6 1 N m (4 0.73 lb ft).
Locate a 12 VDC or 24 VDC power supply that is always available even when the key is turned "OFF".
Connect the power wires from the wiring harness to the power supply. Install a 15 AMP fuse in this circuit. If an additional wire must be spliced, use a 14 gauge wire.
Attach the appropriate connectors to the pressure sensor, the temperature sensor, and the lamp group. Note: The service tool that is used in this installation is Caterpillar Electronic Technician (CAT ET). The service tool connector is a 9 pin Deutsch connector that contains the CDL (Caterpillar Data Link)/ATA, CAN/J1939, and power. A connection from the 274-7578 Monitor Electronic Control Module to the PC requires a Caterpillar Communications adapter, which connects to the PC via a serial port.The service tool (CAT ET) supports the following functions:
Download and review active alarms and logged alarms
Clear active alarms
View the data in real time.
Flash the diagnostic module.
Provide the capability for the user to configure certain parameters.Software Configuration
Refer to Systems Operation, Troubleshooting, Testing and Adjusting, KENR6695 for a description of controllable parameters and operation instructions.Once the 274-7578 Monitor Electronic Control Modulehas power, the 274-7578 Monitor Electronic Control Module will begin monitoring the pressure sensors and the temperature sensors.
Check whether CAT ET is configured with English or Metric units.
Set CAT ET to Metric units if a Metric unit is not already selected. Specifications
Table 3
System Requirements
Requirements for 12VDC or 24VDC System Value Notes
Operating Voltage Minimum +9V Minimum continuous operating voltage without damage to the ECM
Maximum Operating Voltage +32V Maximum continuous operating voltage without damage to the ECM
The voltage is over the maximum voltage that is allowed (two minutes continuous). +80V At 25 °C (77 °F)
Reverse Voltage (one hour) -32V At 85 °C (185 °F)
Power up voltage for the ECM +9V The minimum voltage for the ECM to internally run. Operating the engine at this voltage will cause the damage to the ECM.
The maximum current draw with key switch off 10mA
Maximum current draw with zero engine speed and no loads being driven 500mA
Maximum continuous operating current draw 10A This highly dependent upon the number and type of loads driven by the ECM
Recommended size for the Battery Fuse. 15A
Table 4
Operating Conditions
Thermal Conditions Vibrations Humidity Tolerance Salt Spray Tolerance Moisture Leakage Chemical Splash Immunity Electrostatic Environment
Operating Temperature Range:

Have questions with 106692-1190?





Group cross 106692-1190 ZEXEL

Isuzu 

9 400 617 805 
1156012581 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156012880 
INJECTION-PUMP ASSEMBLY
6RB1T
 
1156012881 
INJECTION-PUMP ASSEMBLY
6RB1T
9 400 617 806 
1156012883 
INJECTION-PUMP ASSEMBLY
6RB1-T
 
1156013430 
INJECTION-PUMP ASSEMBLY
6RB1T
 
1156014421 
INJECTION-PUMP ASSEMBLY
6RB1T
 
1156018500 
INJECTION-PUMP ASSEMBLY
6RB1-T
9 400 617 807 
1156015652 
INJECTION-PUMP ASSEMBLY
6RB1
9 400 617 808 
1156016780 
INJECTION-PUMP ASSEMBLY
E120
F 019 Z10 045 
1156018280 
INJECTION-PUMP ASSEMBLY
6RB1T
 
1156018260 
INJECTION-PUMP ASSEMBLY
6RB1T
106692-1190  
 
1156018400 
INJECTION-PUMP ASSEMBLY
6RB1