Information injection-pump assembly
BOSCH
9 400 617 807
9400617807
ZEXEL
106692-1150
1066921150
ISUZU
1156015652
1156015652
Rating:
Service parts 106692-1150 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
8.
_
9.
_
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
22.1{225}
15.
NOZZLE SET
Include in #1:
106692-1150
as INJECTION-PUMP ASSEMBLY
Cross reference number
BOSCH
9 400 617 807
9400617807
ZEXEL
106692-1150
1066921150
ISUZU
1156015652
1156015652
Zexel num
Bosch num
Firm num
Name
106692-1150
9 400 617 807
1156015652 ISUZU
INJECTION-PUMP ASSEMBLY
6RB1 K 14CA INJECTION PUMP ASSY PE6P,6PD PE
6RB1 K 14CA INJECTION PUMP ASSY PE6P,6PD PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
3
2.95
3.05
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-4 deg. 60 59.5 60.5
Cal 1-4 deg. 60 59.5 60.5
Difference between angles 2
Cyl.1-2 deg. 120 119.5 120.5
Cyl.1-2 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cal 1-3 deg. 240 239.5 240.5
Cal 1-3 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-5 deg. 300 299.5 300.5
Cal 1-5 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
8.3
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
119.5
117.5
121.5
Max. variation between cylinders
%
0
-3
3
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
5.5+-0.5
Pump speed
r/min
365
365
365
Average injection quantity
mm3/st.
10.8
7.6
14
Max. variation between cylinders
%
0
-13
13
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Injection quantity adjustment_03
Adjusting point
C
Rack position
12.9+-0.
5
Pump speed
r/min
150
150
150
Average injection quantity
mm3/st.
220
220
240
Fixing the lever
*
Rack limit
*
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)RACK LIMIT
(3)Set idle sub-spring
(4)Main spring setting
(5)Rack difference from N = N1
----------
K=6 N1=1000r/min
----------
----------
K=6 N1=1000r/min
----------
Speed control lever angle
F:Full speed
I:Idle
(1)Stopper bolt setting
----------
----------
a=7deg+-5deg b=26deg+-5deg
----------
----------
a=7deg+-5deg b=26deg+-5deg
Stop lever angle
N:Pump normal
S:Stop the pump.
----------
----------
a=22deg+-5deg b=46deg+-5deg
----------
----------
a=22deg+-5deg b=46deg+-5deg
Information:
Requirements For The ECM
The Electronic Control Module (ECM) for the Diesel Particulate Filter Monitor System is powered by either a +12 VDC or +24 VDC nominal battery. Refer to Table 1 for the limits for the voltage for the ECM. Refer to Illustration There is one 5 VDC +/-0.25 VDC at 500 mA auxiliary Power Supply on the ECM, routed to the machine pin group. A single return pin is used for this power supply. An "AD" channel monitors this power supply. The ECM internal power supply will provide +5 VDC for external sensor use. Refer to Illustration 1.
Illustration 1 g01340837
Illustration 2 displays mounting the Diesel Particulate Filter Monitor System to the ECM.
Illustration 2 g01340267
Table 1
Power Supply Requirements    
Requirements for 12 VDC or 24 VDC system     Value     Notes    
Operating Minimum Voltage     +9V     Minimum continuous operating voltage without damage to the ECM    
Operating Minimum Voltage     +32V     Maximum continuous operating voltage without damage to the ECM    
Overvoltage Maximum (two minutes continuous)     +80V     At 25 °C (77 °F)    
Reverse Voltage (one hours)     -32V    
85 °C (185 °F)    
power up voltage for the ECM     +9V     Minimum voltage for the ECM in order to run internally. Operating the engine at this voltage will cause damage to the ECM.    
Cranking Voltage            
Maximum current draw with key switch off     10mA        
Maximum current draw with 0 engine speed and no loads being driven     500mA        
Maximum continuous operating current draw     10A     This is highly dependent upon the number and type of loads driven by the ECM.    
Recommended Battery Fuse size     15A        Programming For The ECM
The ECM is flash programmed via the Customer Data Link (CDL) with the service tool.Key Switch For The ECM
The ECM Key Switch provides the ability to shut down the ECM via a low current switch. The ECM Key Switch also increases the life of the batteries by shutting the ECM off. The Key Switch also allows operators to remotely power off the ECM. The Key Switch controls when the ECM powers up. With the Key Switch "OFF", the ECM current draw will not exceed 10mA.Connector For The ECM
The ECM uses a 70 pin connector to connect to the OEM vehicle wiring harness. The ECM Connector Screw torque should be 6 1 N m (4 0.7 lb ft)Connector Wire Gauge Size For The ECM
The battery positive and negative connections must be made with 14 gauge SAE J1128 type GXL wire for the Deutsch stamped and formed terminal or the Deutsch solid terminal. All other connections may be16 gauge or 18 gauge SAE J1128 type SXL or 14, 16 or 18 gauge SAE J1128 type GXL (or equivalent wire).For most components on the engine an 18 gauge wire has sufficient current capacity, however, many applications will benefit from the increased reliability and durability of 16 gauge
The Electronic Control Module (ECM) for the Diesel Particulate Filter Monitor System is powered by either a +12 VDC or +24 VDC nominal battery. Refer to Table 1 for the limits for the voltage for the ECM. Refer to Illustration There is one 5 VDC +/-0.25 VDC at 500 mA auxiliary Power Supply on the ECM, routed to the machine pin group. A single return pin is used for this power supply. An "AD" channel monitors this power supply. The ECM internal power supply will provide +5 VDC for external sensor use. Refer to Illustration 1.
Illustration 1 g01340837
Illustration 2 displays mounting the Diesel Particulate Filter Monitor System to the ECM.
Illustration 2 g01340267
Table 1
Power Supply Requirements    
Requirements for 12 VDC or 24 VDC system     Value     Notes    
Operating Minimum Voltage     +9V     Minimum continuous operating voltage without damage to the ECM    
Operating Minimum Voltage     +32V     Maximum continuous operating voltage without damage to the ECM    
Overvoltage Maximum (two minutes continuous)     +80V     At 25 °C (77 °F)    
Reverse Voltage (one hours)     -32V    
85 °C (185 °F)    
power up voltage for the ECM     +9V     Minimum voltage for the ECM in order to run internally. Operating the engine at this voltage will cause damage to the ECM.    
Cranking Voltage            
Maximum current draw with key switch off     10mA        
Maximum current draw with 0 engine speed and no loads being driven     500mA        
Maximum continuous operating current draw     10A     This is highly dependent upon the number and type of loads driven by the ECM.    
Recommended Battery Fuse size     15A        Programming For The ECM
The ECM is flash programmed via the Customer Data Link (CDL) with the service tool.Key Switch For The ECM
The ECM Key Switch provides the ability to shut down the ECM via a low current switch. The ECM Key Switch also increases the life of the batteries by shutting the ECM off. The Key Switch also allows operators to remotely power off the ECM. The Key Switch controls when the ECM powers up. With the Key Switch "OFF", the ECM current draw will not exceed 10mA.Connector For The ECM
The ECM uses a 70 pin connector to connect to the OEM vehicle wiring harness. The ECM Connector Screw torque should be 6 1 N m (4 0.7 lb ft)Connector Wire Gauge Size For The ECM
The battery positive and negative connections must be made with 14 gauge SAE J1128 type GXL wire for the Deutsch stamped and formed terminal or the Deutsch solid terminal. All other connections may be16 gauge or 18 gauge SAE J1128 type SXL or 14, 16 or 18 gauge SAE J1128 type GXL (or equivalent wire).For most components on the engine an 18 gauge wire has sufficient current capacity, however, many applications will benefit from the increased reliability and durability of 16 gauge
Have questions with 106692-1150?
Group cross 106692-1150 ZEXEL
Isuzu
106692-1150
9 400 617 807
1156015652
INJECTION-PUMP ASSEMBLY
6RB1
6RB1