106691-4113 ZEXEL 9 400 617 792 BOSCH INJECTION-PUMP ASSEMBLY 9400617792 1066914113 6156711210


 

Information injection-pump assembly

BOSCH 9 400 617 792 9400617792
ZEXEL 106691-4113 1066914113
KOMATSU 6156711210 6156711210
106691-4113 INJECTION-PUMP ASSEMBLY
Rating:
43
Buy INJECTION-PUMP ASSEMBLY 106691-4113 zexel genuine, new aftermarket engine parts with delivery

Service parts 106691-4113 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106069-7572
3. GOVERNOR 105407-8203
4. SUPPLY PUMP 105217-6030
5. AUTOM. ADVANCE MECHANIS 105681-6110
6. COUPLING PLATE 105663-0920
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105111-5090
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 27.5{280}
13. NOZZLE-HOLDER 105041-7130
14. NOZZLE 105025-4060
15. NOZZLE SET

Include in #1:

106691-4113 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106691-4113 
9 400 617 792 
6156711210  KOMATSU
INJECTION-PUMP ASSEMBLY
SAA6D125 K




Information:

password protection for the CCM is initially enabled. Password protection may be necessary for some applications. Use the following procedure to enable password protection. Changing the password protection can be done with the PC software for the CCM . The password protection can also be changed by using a host device to write the IIDs.Disabling PasswordsTo disable the passwords, the AA12 and AA8A PIDs must be used.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA8A with the level 3 password. This will set the security level in the CCM to level 3. The message will be 5000340C0061AA8Ab1b2b3b4b5b6b7b8cs. The example above shows that b1 through b8 are the ASCII characters of the password. If the password is all spaces, simply end the message after PID AA8A. Do not include any of the data bytes. The CCM will automatically add spaces when a character is not present.
Use IID 34 with a unit number of 61. Write PID AA 12 with bit 3 set. This will disable the password protection. The message will be 500034050061AA1204cs. This message will disable the passwords. Baud rate changes will be enabled. The CCM will be set for a direct connection. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way. Note: When the passwords are disabled, all three passwords are set to all blanks (spaces).Enabling PasswordsThe AA12 and the F012 PIDs must be used in order to enable the password protection.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA12 to clear bit 3. The message format will be 500034050061AA1200cs. This message will enable the following items: passwords, change of baud rate and set the CCM for direct connect. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way.
In order to enable the changes, the power to the CCM must be cycled or the security level must be written to zero. The security level is written to zero by using IID 34. The message will be 500034050061F01200cs. Note: When the passwords were disabled, each character was set to a blank or space. Set the level 3 password on the CCM to something other than spaces.

Have questions with 106691-4113?





Group cross 106691-4113 ZEXEL

Yanmar 

9 400 610 998 
12861251010 
INJECTION-PUMP ASSEMBLY
6GHD50A
9 400 613 072 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
9 400 613 307 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

106691-4113  
9 400 617 792 
6156711210 
INJECTION-PUMP ASSEMBLY
SAA6D125
9 400 613 396 
6156711220 
INJECTION-PUMP ASSEMBLY
SAA6D125