106691-3051 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1066913051 220003871a


 

Information injection-pump assembly

ZEXEL 106691-3051 1066913051
HINO 220003871A 220003871a
106691-3051 INJECTION-PUMP ASSEMBLY
Rating:
14
Buy INJECTION-PUMP ASSEMBLY 106691-3051 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
106691-3051 
 
220003871A  HINO
INJECTION-PUMP ASSEMBLY
ER200 * K




Information:

The results of the preceding procedure are in the following list:
The output corresponds to the desired pressure range. Stop.
The output does not correspond to the desired pressure range. Proceed to 3.
Calibrate the transducer. This assumes that the transducer is mounted on the engine.
Turn the isolation valve on the transducer mounting. This isolates the transducer from the engine. An arrow on the valve indicates the direction of flow. See illustration 2.
Apply a pressure that is equal to 4 mA to the transducer. See table 1. See the pressure port connection in illustration 2.
Monitor the ammeter. Adjust the zero dial until the ammeter reads 4mA. See the location of the zero dial that is in illustration 1.
Apply the pressure that is equal to 20mA to the transducer. See table 1. See the pressure port connection in illustration 2.Note: The full range of pressure may not be available. Use partial pressure. Use the highest possible pressure. This will yield the best accuracy. See table 1.
Monitor the ammeter. Adjust the zero dial until the ammeter reads 20mA. See the location of the zero dial that is in illustration 1.
Apply the pressure that is equal to 4mA to the transducer. Verify that the ammeter displays 4mA.The results of the preceding procedure are in the following list:
The output corresponds to the desired pressure range. The transducer is calibrated. Stop.
The output does not correspond to the desired pressure range. Proceed to 4.
Reapply the pressure.
Apply the pressure that is equal to 4mA to the transducer. See table 1. See the pressure port connection in illustration 2.
Monitor the ammeter. Adjust the zero dial until the ammeter reads 4mA. See the location of the zero dial that is in illustration 1.
Apply the pressure that is equal to 20mA to the transducer. See table 1. See the pressure port connection in illustration 2.Note: The full range of pressure may not be available. Use partial pressure. Use the highest possible pressure. This will yield the best accuracy. See table 1.
Monitor the ammeter. Adjust the zero dial until the ammeter reads 20mA. See the location of the zero dial that is in illustration 1.
Apply the pressure that is equal to 4mA to the transducer. Verify that the ammeter displays 4mA.The results of the preceding procedure are in the following list:Note: Repeat the procedure several times in order to properly calibrate the transducer. Continue until the 4mA signal is correct and the 20mA signal is correct.
The output corresponds to the desired pressure range. The transducer is calibrated. Stop.
The output does not correspond to the desired pressure range. Replace the transducer. Verify that the repair resolves the problem. Stop.

Have questions with 106691-3051?





Group cross 106691-3051 ZEXEL

Hino 

 
220002030C 
INJECTION-PUMP ASSEMBLY
ER200
 
220002031B 
INJECTION-PUMP ASSEMBLY
ER200
 
220002190A 
INJECTION-PUMP ASSEMBLY
ER200
9 400 617 782 
220002191B 
INJECTION-PUMP ASSEMBLY
ER200
 
220201480A 
INJECTION-PUMP ASSEMBLY
ER100
 
220201481A 
INJECTION-PUMP ASSEMBLY
ER100
 
220201483A 
INJECTION-PUMP ASSEMBLY
ER100
 
220201484A 
INJECTION-PUMP ASSEMBLY
ER100
 
220201570A 
INJECTION-PUMP ASSEMBLY
ER100
 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 617 783 
220201572A 
INJECTION-PUMP ASSEMBLY
ER100
 
220003870A 
INJECTION-PUMP ASSEMBLY
ER200
106691-3051  
 
220003871A 
INJECTION-PUMP ASSEMBLY
ER200
 
220201900A 
INJECTION-PUMP ASSEMBLY
ER100
9 400 617 784 
220004210A 
INJECTION-PUMP ASSEMBLY
ER200
 
220004380A 
INJECTION-PUMP ASSEMBLY
ER200
Back to top