106691-1911 ZEXEL 9 400 617 771 BOSCH INJECTION-PUMP ASSEMBLY 9400617771 1066911911 1156007331


 

Information injection-pump assembly

BOSCH 9 400 617 771 9400617771
ZEXEL 106691-1911 1066911911
ISUZU 1156007331 1156007331
106691-1911 INJECTION-PUMP ASSEMBLY
Rating:
70
Buy INJECTION-PUMP ASSEMBLY 106691-1911 zexel genuine, new aftermarket engine parts with delivery

Service parts 106691-1911 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106069-1111
3. GOVERNOR 105407-1010
4. SUPPLY PUMP 105237-1221
5. AUTOM. ADVANCE MECHANIS 105614-0460
6. COUPLING PLATE 105662-0350
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-4891
11. Nozzle and Holder 1-15300-041-2
12. Open Pre:MPa(Kqf/cm2) 22.1{225}
13. NOZZLE-HOLDER 105031-4171
14. NOZZLE 105015-3520
15. NOZZLE SET

Include in #1:

106691-1911 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 617 771 9400617771
ZEXEL 106691-1911 1066911911
ISUZU 1156007331 1156007331


Zexel num
Bosch num
Firm num
Name
106691-1911 
9 400 617 771 
1156007331  ISUZU
INJECTION-PUMP ASSEMBLY
E120 K 14CA INJECTION PUMP ASSY PE6P,6PD PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   132424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   3 2.95 3.05
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.5 60.5
Difference between angles 2
Cyl.1-2
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cal 1-3
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-5
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   7.3+-0.5
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   113 109.2 116.8
Max. variation between cylinders %   0 -3 3
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   7.3
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   106.8 103 110.6
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   5.5+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   22.5 19.3 25.7
Max. variation between cylinders %   0 -13 13
Fixing the rack   *

Test data Ex:

Governor adjustment

Test data 106691-1911
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)Tolerance for racks not indicated: +-0.05mm.
----------
K=18
----------

Speed control lever angle

Test data 106691-1911
F:Full speed I:Idle S:Stop
----------

----------
a=17deg+-5deg b=32deg+-5deg c=32deg+-3deg

Stop lever angle

Test data 106691-1911
N:Pump normal S:Stop the pump. (1)Normal
----------

----------
a=10deg+-5deg b=53deg+-5deg




Information:

Problem 4
The starting motor remains engaged or the starting motor continues to run after the engine is running.
Check the components of the starting circuit.
Measure the voltages at terminal (TS-26) of the junction box while the engine is running.Result
The voltage at the terminal is zero volts.The problem is in the starting motor (SM), the pinion solenoid (PS), or the magnetic switch (MS). Repair the faulty component. STOP.
The voltage at the terminal is between 15 volts and 32 volts.The START terminals of the start/stop switch are normally closed. This is normal for an automatic start system. In a manual start system, the switches should be normally open. The switch is on terminals (SSS-1) and (SSS-2) for a normal start/stop switch. Repair the faulty switch. STOP.Problem 5
The engine shutdown occurs after the engine runs for more than 3 minutes.
Check the protection switches.
Remove the jumper that is between terminals (TS-9) and (TS-10) of the junction box.
If the engine is equipped with a low oil pressure indicator, disconnect the diode that is between terminals (TS-8) and (TS-10). The cathode lead of the diode should be connected to terminal (TS-10).
If the engine is equipped with a low oil pressure indicator, ensure that a jumper is not installed between terminals (TS-8) and (TS-9).
Start the engine.
Reconnect the jumper that is between terminals (TS-9) and (TS-10) of the junction box after the test is completed.Result
The engine starts and the engine runs.The problem is in the oil pressure switch or the water temperature contactor switch. Go to Step 5 of "Problem 1".
The engine starts but engine shutdown occurs immediately.Go to Step 1 of "Problem 3".
The engine starts and the engine runs but engine shutdown occurs after the engine runs for more than 3 minutes.Go to Step 2.
The engine cranks but the engine does not start.Go to Step 1 of "Problem 1".
Check the start/stop switch and slave relay (SR1).
Disconnect the wire in the junction box that connects terminal (SR1-85) of the slave relay (SR1) to terminal (TD-7) of the time delay relay (TD).
Crank the engine. Activate the emergency stop switch, if necessary.Result
The engine starts and the engine runs.The start/stop switch has a short circuit or a wiring problem is causing a voltage at terminal (TD-7). Reconnect the wire to the terminal. STOP.
Engine shutdown still occurs after several minutes.The contacts of (SR1) periodically close. The problem may also be with the governor or the fuel supply to the engine. Refer to the Engine Service Manual. If a 2301A Electric Governor is used, the SR1 contacts may be opening. Refer to 2301A Electric Governor Service Manual, SENR3585. Test SR1. Refer to Testing and Adjusting, "Slave Relay Test".Problem 6
Engine shutdown does not occur when a fault is detected.
Check the protection switches and the crank terminate switch of the electronic speed switch.
Reset circuit breaker (CB7).
Start the engine and run the engine at low idle.
Contact with electrical components can cause injury or death.Remove all jewelry and avoid contact with electrical components. Use properly insulated tools when working on the junction box of an

Have questions with 106691-1911?





Group cross 106691-1911 ZEXEL

Isuzu 

 
1156001272 
INJECTION-PUMP ASSEMBLY
E120
106691-1911  
9 400 617 771 
1156007331 
INJECTION-PUMP ASSEMBLY
E120
 
1156007371 
INJECTION-PUMP ASSEMBLY
E120
9 400 610 183 
1156007381 
INJECTION-PUMP ASSEMBLY
E120
 
9812011121 

E120
9 400 617 772 
9812011203 
INJECTION-PUMP ASSEMBLY
E120
 
9812011723 
INJECTION-PUMP ASSEMBLY
E120
9 400 619 810 
9812011724 
INJECTION-PUMP ASSEMBLY
E120
9 400 617 773 
1156007350 
INJECTION-PUMP ASSEMBLY
E120
 
1156001671 

E120
 
1156001851 

E120
Back to top