106689-4010 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1066894010 6215711120


 

Information injection-pump assembly

ZEXEL 106689-4010 1066894010
KOMATSU 6215711120 6215711120
106689-4010 INJECTION-PUMP ASSEMBLY
Rating:
23
Buy INJECTION-PUMP ASSEMBLY 106689-4010 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

ZEXEL 106689-4010 1066894010
KOMATSU 6215711120 6215711120


Zexel num
Bosch num
Firm num
Name
106689-4010 
106689-4015 
 
6215711120  KOMATSU
INJECTION-PUMP ASSEMBLY
SA12V140 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8130
Bosch type code   EFEP215A
Nozzle   105780-0050
Bosch type code   DN6TD119NP1T
Nozzle holder   105780-2090
Bosch type code   EFEP215
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131424-7120
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.5 3.45 3.55
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   15.3
Pump speed r/min   1050 1050 1050
Average injection quantity mm3/st.   345.2 343.2 347.2
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the rack   *
Remarks
Standard point A's rack position same as 106681-4020 in row L
 
Injection quantity adjustment_02
Adjusting point   -
Rack position   9.3+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   20 18.5 21.5
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Injection quantity adjustment_03
Remarks
Rack limit setting R = 16.5+0.2
 
Timer adjustment
Pump speed r/min   800--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   750
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1050
Advance angle deg.   2.5 2 3
Remarks
Finish
 

Test data Ex:

Timing setting

Test data 106689-4010
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(150deg)




Information:

(1) Oil cooler base bypass valve. Opening pressure ... 155 17 kPa (22.5 2.5 psi)(2) Base assembly. Tighten stud that holds filter assembly (3) to a torque of ... 68 7 N m (50 5 lb ft)(3) Filter assembly.(4) Cover. Tighten to a torque of ... 60 10 N m (44 7 lb ft)(5) Seal. Lubricate seal with lubricant being sealed.
Section A-A. Oil Filter Bypass Valve.The bypass opening pressure differential is 170 kPa (25 psi).(6) Seal.(7) Spring (8M3182): Assembled length ... 63.5 mm (2.50 in)Load at assembled length ... 36.5 N (8.92 lb)Free length after test ... 91.7 mm (3.61 in)Outside diameter ... 20.6 mm (.81 in)(8) Seal.(9) Plunger.
Section B-B. Oil Pump Bypass Valve.(10) Spring (2N6005): Assembled length ... 96.52 mm (3.800 in)Load at assembled length ... 92.52 N (20.817 lb)Operating length (min) ... 45.72 mm (1.800 in)Load at min operating length ... 257.55 N (57.949 lb)Free length after test ... 124.71 mm (4.910 in)Outside diameter ... 21.84 mm (.860 in)(11) Valve.(12) Seal.(13) Seal.
Section C-C. High Pressure Relief Valve.The relief pressure is 696 kPa (101 psi).(14) Spacer.(15) Spring (1A2170): Assembled length ... 21.43 mm (.844 in)Load at assembled length ... 198.03 13.35 N (44.500 3.000 lb)Free length after test ... 31.00 mm (1.220 in)Outside diameter ... 19.60 mm (.772 in)(16) Seal.
Oil Cooler Bypass Valve.(17) Minimum stroke ... 8.4 mm (.33 in)(18) Length of valve fully compressed ... 44.2 1 mm (1.70 .04 in)(19) Length of valve fully extended ... 52.6 1 mm (2.10 .04 in)(B) Position "B".Valve Data: Start to close temperature ... 100 to 102.8° C (212 to 217° F)Position "B" temperature activation ... 111.1° C (232° F)Position "B" bypass opening pressure differential ... 155 17 kPa (22 2 psi)Fail safe activation temperature ... 126.7° C (260° F) Unit will stroke to and remain at position "B" at failsafe activation temperature.

Have questions with 106689-4010?





Group cross 106689-4010 ZEXEL

Komatsu 

106689-4010  

106689-4015 
 
6215711120 
INJECTION-PUMP ASSEMBLY
SA12V140
 
6215711121 
INJECTION-PUMP ASSEMBLY
SA12V140
 
 
INJECTION-PUMP ASSEMBLY
9 400 611 285 
 
INJECTION-PUMP ASSEMBLY
SA12V140

Komatsu 

9 400 613 129 
6215711122 
INJECTION-PUMP ASSEMBLY
SA12V140
Back to top