Information injection-pump assembly
BOSCH
9 400 617 577
9400617577
ZEXEL
106682-4781
1066824781
KOMATSU
6215711513
6215711513

Rating:
Service parts 106682-4781 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
24.5(250)
15.
NOZZLE SET
Include in #1:
106682-4781
as INJECTION-PUMP ASSEMBLY
Cross reference number
Zexel num
Bosch num
Firm num
Name
106682-4781
9 400 617 577
6215711513 KOMATSU
INJECTION-PUMP ASSEMBLY
SA12V140 K
SA12V140 K
Information:
6N9294 Alternator Group, 3T6352 Alternator 24V 35A (Delco-Remy Number 1117647)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 6500Output voltage ... 27.5 1.0VOutput (cold) ... 35A(1) Torque for the ground terminal nut ... 2.25 0.25 N m (20 2.5 lb in)(2) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(3) Torque for the output terminal nut ... 7.1 0.9 N m (64 8 lb in)3T6353 Regulator (Delco-Remy Number 1984287) Inside Alternator
Voltage setting ... No adjustmentPermissible voltage range ... 26 to 30VDelco-Remy (27SI)
9L5938 12V 65A (Delco-Remy Number 1105460) 3T7070 12V 65A (Delco-Remy Number 1105464)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 14.0 0.5VOutput (cold) ... 58ATorque for the ground terminal nut ... 9.0 3.0 N m (80 27 lb in)Torque for the output terminal nut ... 3.4 0.6 N m (30 5 lb in)(1) Torque for the pulley nut ... 100 7 N m (75 5 lb ft)(2) Brush length (new) ... 24 mm (.94 in)(3) Slip Rings: Maximum Runout (TIR) ... 0.05 mm (.002 in)Minimum Diameter ... 29.3 mm (1.15 in)9L6774 Regulator (Delco-Remy Number 1116406) Inside Alternator
Voltage setting ... No adjustmentPermissible voltage range ... 14 0.5VBosch
6N9294 Alternator Group, 7N9720 Alternator 24V 35A (Bosch Number 0-122-469-001)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 4000Output voltage ... 27.5 1.0VOutput (cold) ... 47ATorque for the ground terminal nut ... 2.1 to 2.8 N m (19 to 25 lb in)(1) Torque for the pulley nut ... 95 to 110 N m (70 to 80 lb ft)(2) Torque for the output terminal nut ... 17 to 22 N m (13 to 16 lb ft)9G7567 Regulator (Bosch Number 1-197-011-000) Under alternator cover. For use with the 7N9720 Alternator.
Voltage rating ... 28VPolarity ... Negative groundVoltage setting range ... 26.7 to 28.3VNippondenso
6N9294 Alternator Group, 9G4574 Alternator 24V 35A (Nippondenso Number 100211-0860)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (cold) ... 35A(1) Torque for the pulley nut ... 95 to 110 N m (70 to 80 lb ft)(2) Torque for the output terminal nut ... 22 to 37 N m (16 to 27 lb ft)(3) Torque for the ground terminal nut ... 3.4 to 5.4 N m (31 to 49 lb in)7T2798 Regulator (Nippondenso Number 126000-0380) - Inside Alternator
Voltage setting ... No AdjustmentPermissible voltage range ... 26.5 to 28.5V
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 6500Output voltage ... 27.5 1.0VOutput (cold) ... 35A(1) Torque for the ground terminal nut ... 2.25 0.25 N m (20 2.5 lb in)(2) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(3) Torque for the output terminal nut ... 7.1 0.9 N m (64 8 lb in)3T6353 Regulator (Delco-Remy Number 1984287) Inside Alternator
Voltage setting ... No adjustmentPermissible voltage range ... 26 to 30VDelco-Remy (27SI)
9L5938 12V 65A (Delco-Remy Number 1105460) 3T7070 12V 65A (Delco-Remy Number 1105464)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 14.0 0.5VOutput (cold) ... 58ATorque for the ground terminal nut ... 9.0 3.0 N m (80 27 lb in)Torque for the output terminal nut ... 3.4 0.6 N m (30 5 lb in)(1) Torque for the pulley nut ... 100 7 N m (75 5 lb ft)(2) Brush length (new) ... 24 mm (.94 in)(3) Slip Rings: Maximum Runout (TIR) ... 0.05 mm (.002 in)Minimum Diameter ... 29.3 mm (1.15 in)9L6774 Regulator (Delco-Remy Number 1116406) Inside Alternator
Voltage setting ... No adjustmentPermissible voltage range ... 14 0.5VBosch
6N9294 Alternator Group, 7N9720 Alternator 24V 35A (Bosch Number 0-122-469-001)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 4000Output voltage ... 27.5 1.0VOutput (cold) ... 47ATorque for the ground terminal nut ... 2.1 to 2.8 N m (19 to 25 lb in)(1) Torque for the pulley nut ... 95 to 110 N m (70 to 80 lb ft)(2) Torque for the output terminal nut ... 17 to 22 N m (13 to 16 lb ft)9G7567 Regulator (Bosch Number 1-197-011-000) Under alternator cover. For use with the 7N9720 Alternator.
Voltage rating ... 28VPolarity ... Negative groundVoltage setting range ... 26.7 to 28.3VNippondenso
6N9294 Alternator Group, 9G4574 Alternator 24V 35A (Nippondenso Number 100211-0860)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (cold) ... 35A(1) Torque for the pulley nut ... 95 to 110 N m (70 to 80 lb ft)(2) Torque for the output terminal nut ... 22 to 37 N m (16 to 27 lb ft)(3) Torque for the ground terminal nut ... 3.4 to 5.4 N m (31 to 49 lb in)7T2798 Regulator (Nippondenso Number 126000-0380) - Inside Alternator
Voltage setting ... No AdjustmentPermissible voltage range ... 26.5 to 28.5V
Have questions with 106682-4781?
Group cross 106682-4781 ZEXEL
Komatsu
Komatsu
Komatsu
Komatsu
Komatsu
Komatsu
Komatsu
106682-4781
9 400 617 577
6215711513
INJECTION-PUMP ASSEMBLY
SA12V140
SA12V140