106675-4270 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1066754270


 

Information injection-pump assembly

ZEXEL 106675-4270 1066754270
106675-4270 INJECTION-PUMP ASSEMBLY
Rating:
66
Buy INJECTION-PUMP ASSEMBLY 106675-4270 zexel genuine, new aftermarket engine parts with delivery

Service parts 106675-4270 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106061-7750
3. GOVERNOR 105407-2450
4. SUPPLY PUMP 105217-1390
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-4750
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 22.6{230}
13. NOZZLE-HOLDER 105031-4220
14. NOZZLE 105015-3250
15. NOZZLE SET

Include in #1:

106675-4270 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106675-4270 
 
   
INJECTION-PUMP ASSEMBLY




Information:


Accidental engine starting can cause injury or death to personnel working on the equipment.To avoid accidental engine starting, disconnect the battery cable from the negative (−) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.Place a Do Not Operate tag at the Start/Stop switch location to inform personnel that the equipment is being worked on.
Water Temperature Fault (WT)
The current flow for the circuit that is described in this section is applicable for all engines. The engine must be running at a speed with a coolant temperature that is hot enough to close the water temperature contactor switch (WTS). The water temperature contactor switch is normally open. The following events occur in the electric circuit in order to shut down the engine. The engine will shut down when the temperature of the coolant system is greater than the maximum temperature that is set for the WTS.
The water temperature contactor switch (WTS) closes across the contacts , which are normally open.
Closing the contacts (WTS-1) and (WTS-2) opens the circuit to slave relay (SR1) (line 33).
When the open circuit de-energizes (SR1) and (SR2), the circuit opens across the relay contacts (SR1-30) and (SR1-87) (line 43).
The open circuit de-energizes the fuel solenoid (FS) which shuts off the fuel flow to the engine. The starter motor circuit can then be engaged. However, there is no fuel flow to the engine and the engine cannot be restarted until the coolant temperature falls below the rating of the water temperature contactor switch. When the water temperature is below the maximum rating for the temperature of the WTS, the circuit opens across contacts (WTS-1) and (WTS-2). The slave relay (SR1) and the fuel solenoid (FS) can then be energized by the engine starting circuit in order to restart the engine.
To avoid possible engine damage or another immediate shutdown, the water temperature fault must be corrected before attempting to restart the engine.
Accidental engine starting can cause injury or death to personnel working on the equipment.To avoid accidental engine starting, disconnect the battery cable from the negative (−) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.Place a Do Not Operate tag at the Start/Stop switch location to inform personnel that the equipment is being worked on.
2301A Electric Governor Control
The 2301A Electric Governor Control activates all of the components that are in the electric protection system. The components are activated in the same manner when the nonelectric governor is used. One difference exists in the main circuit. The fuel shutoff solenoid (FSOS) (line 43) is not used.When the electric governor control is used, the engine must run in a normal condition in order for the electric circuit to operate in the manner that is described below.
Current flows from the terminals (TS-28) (line 30) and (TS-31) (line 31), which

Have questions with 106675-4270?





Group cross 106675-4270 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

 
6152711430 
INJECTION-PUMP ASSEMBLY
SA6D125
9 400 617 384 
6152711431 
INJECTION-PUMP ASSEMBLY
SA6D125
 
6152711440 
INJECTION-PUMP ASSEMBLY
SA6D125
 
6152711441 
INJECTION-PUMP ASSEMBLY
SA6D125
 
6152711442 
INJECTION-PUMP ASSEMBLY
SA6D125
9 400 612 378 
6152711443 
INJECTION-PUMP ASSEMBLY
SA6D125
 
6211711680 
INJECTION-PUMP ASSEMBLY
S6D140
9 400 617 385 
6211711681 
INJECTION-PUMP ASSEMBLY
S6D140
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Yanmar 

F 019 Z10 535 
12665251880 
INJECTION-PUMP ASSEMBLY
6HAL-T
 
 
INJECTION-PUMP ASSEMBLY

Yanmar 

 
12665251890 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Yanmar 

 
12665251890 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Yanmar 

 
12665251890 
INJECTION-PUMP ASSEMBLY
F 019 Z10 536 
12665251890 
INJECTION-PUMP ASSEMBLY
6HAL-T
F 019 Z10 198 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 617 386 
6211711480 
INJECTION-PUMP ASSEMBLY
S6D140
 
 
INJECTION-PUMP ASSEMBLY

Yanmar 

 
12664551880 
INJECTION-PUMP ASSEMBLY
6HAL-TN
106675-4270  
 
 
INJECTION-PUMP ASSEMBLY

Yanmar 

 
12664551851 
INJECTION-PUMP ASSEMBLY
6HAL-N
 
 
INJECTION-PUMP ASSEMBLY

Yanmar 

 
12664551051 
INJECTION-PUMP ASSEMBLY
6HAL
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

 
6152721390 
INJECTION-PUMP ASSEMBLY
SA6D125E
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 613 142 
6152721391 
INJECTION-PUMP ASSEMBLY
SA6D125E
9 400 612 124 
6152721392 
INJECTION-PUMP ASSEMBLY
SA6D125E
Back to top