106673-4030 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1066734030


 

Information injection-pump assembly

ZEXEL 106673-4030 1066734030
106673-4030 INJECTION-PUMP ASSEMBLY
Rating:
19
Buy INJECTION-PUMP ASSEMBLY 106673-4030 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

ZEXEL 106673-4030 1066734030


Zexel num
Bosch num
Firm num
Name
106673-4030 
 
  DPICO
INJECTION-PUMP ASSEMBLY
6D22TCI * Q

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131424-4620
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.8 4.75 4.85
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   10.5
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   145.3 142.3 148.3
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   5.8+-0.5
Pump speed r/min   275 275 275
Average injection quantity mm3/st.   15 12.4 17.6
Fixing the rack   *
Remarks
(check)
 
Injection quantity adjustment_03
Adjusting point   C
Rack position   5.2+-0.5
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   15 12.4 17.6
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Injection quantity adjustment_04
Adjusting point   D
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   142 122 162
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1050--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1000
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1100
Advance angle deg.   1.5 1 2
Timer adjustment_04
Pump speed r/min   -
Advance angle deg.   2 2 2
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 106673-4030
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT (4)Main spring setting (5)Set idle sub-spring (6)Torque spring does not operate. (7)At delivery
----------
K=7
----------

Speed control lever angle

Test data 106673-4030
F:Full speed I:Idle (1)Set the pump speed at aa (2)Stopper bolt setting (3)At delivery (4)Set the pump speed at bb. (5)Stopper bolt setting
----------
aa=910r/min bb=1110r/min
----------
a=9deg+-5deg b=(2deg) c=7deg+-5deg d=29deg+-5deg

Stop lever angle

Test data 106673-4030
N:Pump normal S:Stop the pump.
----------

----------
a=19deg+-5deg b=53deg+-5deg

Timing setting

Test data 106673-4030
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(7deg)




Information:

Warning Operation
Two flashing warning lamps and an alarm inform the operator that: * An ether cylinder is empty.* Both ether cylinders are empty.* A noncritical fault is present.* A critical fault is present.The warning lamps and alarm can be tested by placing the ether system switch in the Test/Disable position. The warning alarm will turn ON for two seconds and the warning lamps will remain ON continuously until the switch is returned to the Auto position. If a solenoid valve is shorted to +BAT, the alarm sounds whenever the key switch is in the RUN or START position. The alarm beeps at the rate of approximately 1.3 seconds ON and 2.0 seconds OFF. The engine could be damaged if ether was injected before the engine is cranked.An Ether Cylinder Is Empty
One of the two warning lamps inform the operator when an ether cylinder is empty. The lamp flashes at the rate of 1.5 Hz (flashes per second) with equal ON and OFF times. The lamps and ether solenoid assemblies are correspondingly marked 1 and 2. When empty ether cylinder warning lamp 1 is flashing, ether cylinder 1 needs replaced. When empty ether cylinder warning lamp 2 is flashing, ether cylinder 2 needs replaced. (On 3516 engines, both ether cylinders of the set need replaced.) The lamps stop flashing when the reset switch is activated during ether cylinder replacement. The empty ether cylinder warning lamp will also flash if there is no ether cylinder installed.Both Ether Cylinders Are Empty
When both ether cylinders are empty (on 3516 engines, both ether cylinder sets), both empty ether cylinder warning lamps and the alarm are activated. Empty ether cylinder warning lamps 1 and 2 flash at the same time, at the rate of 1.5 Hz (flashes per second). The alarm also sounds, during the ether injection time, approximately 1.3 seconds ON and 2.0 seconds OFF.A Noncritical Fault Is Present
When a noncritical fault is present, both empty ether cylinder warning lamps are activated. Empty ether cylinder warning lamps 1 and 2 flash alternately (taking turns ON and OFF) at the rate of 3.0 Hz (flashes per second). The system continues to operate during a noncritical fault.A Critical Fault Is Present
When a critical fault is present. both empty ether cylinder warning lamps and the alarm are activated. Empty ether cylinder warning lamps 1 and 2 flash alternately (taking turns ON and OFF) at the rate of 3.0 Hz (flashes per second). The alarm also sounds, during the ether injection time, approximately 1.3 seconds ON and 2.0 seconds OFF. If possible, ether injections are disabled during a critical fault.Diagnostic Operation
Ether Injection Control DiagnosticsThe ether injection control has diagnostic capabilities to assist in troubleshooting. The control detects and records faults that occur to the system. During a critical fault, if possible, the control disables ether injection. During a noncritical fault, the control takes alternate action so that the system continues to function.The diagnostic display, on the ether injection control, displays a code which represents the fault that

Have questions with 106673-4030?





Group cross 106673-4030 ZEXEL

Hyundai 

9 400 617 308 
 
INJECTION-PUMP ASSEMBLY
6D22TC

Niigata-Urawa 

9 400 611 458 
75L47043A 
INJECTION-PUMP ASSEMBLY
DMF13HZA
9 400 617 309 
75L47043B 
INJECTION-PUMP ASSEMBLY
DMF13HZA

Mitsubishi-Heav 

 
3626550190 
INJECTION-PUMP ASSEMBLY
S6B-TA
 
3626560190 
INJECTION-PUMP ASSEMBLY
S6B-TA
9 400 617 310 
3626570190 
INJECTION-PUMP ASSEMBLY
S6B-TA

Dpico 

106673-4030  
 
 
INJECTION-PUMP ASSEMBLY
6D22TCI

Mitsubishi-Heav 

9 400 611 666 
3626570290 
INJECTION-PUMP ASSEMBLY
S6B
9 400 612 228 
3626580290 
INJECTION-PUMP ASSEMBLY
S6B

Dpico 

F 019 Z20 120 
 
INJECTION-PUMP ASSEMBLY
AM928
9 400 612 005 
 
INJECTION-PUMP ASSEMBLY
KK-TCI
F 019 Z20 121 
 
INJECTION-PUMP ASSEMBLY
KK-TCI
F 019 Z20 122 
 
INJECTION-PUMP ASSEMBLY
KK-TCI
F 019 Z20 123 
 
INJECTION-PUMP ASSEMBLY
KK-TCI