106673-3300 ZEXEL 9 400 617 300 BOSCH INJECTION-PUMP ASSEMBLY 9400617300 1066733300 220205930a


 

Information injection-pump assembly

BOSCH 9 400 617 300 9400617300
ZEXEL 106673-3300 1066733300
HINO 220205930A 220205930a
106673-3300 INJECTION-PUMP ASSEMBLY
Rating:
18
Buy INJECTION-PUMP ASSEMBLY 106673-3300 zexel genuine, new aftermarket engine parts with delivery

Service parts 106673-3300 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106060-7941
3. GOVERNOR 105407-1492
4. SUPPLY PUMP 105207-1770
5. AUTOM. ADVANCE MECHANIS 105635-0041
6. COUPLING PLATE 105663-1130
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-4530
11. Nozzle and Holder 236001026A
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105031-5300
14. NOZZLE 105015-4120
15. NOZZLE SET

Include in #1:

106673-3300 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106673-3300 
9 400 617 300 
220205930A  HINO
INJECTION-PUMP ASSEMBLY
EK130 K 14CA INJECTION PUMP ASSY PE6P,6PD PE




Information:

Solenoid Valve Replacement
Make reference to the at the beginning of the Testing And Adjusting section.
This procedure assumes that the ether cylinder mounted on the failed solenoid valve may still contain ether and is usable. If the ether cylinder is empty and needs replacement, complete this procedure and then follow the normal cylinder replacement procedure. See Ether Cylinder Replacement.
Solenoid Valve Assembly The solenoid valve itself is not serviceable. The complete solenoid valve assembly must be replaced. This includes the mounting bracket.1. Turn the disconnect switch to the OFF position. 2. Remove the ether cylinder from failed solenoid valve (1).3. Disconnect ether line (2) from the outlet of failed solenoid valve (1).4. Disconnect (unplug) solenoid valve harness connector (3). 5. Remove the reset switch bracket from the solenoid valve by removing two bolts (4). Leave the reset switch and wires intact on the bracket.6. Remove the solenoid valve assembly, which includes the mounting bracket, from the vehicle by removing two bolts (5).
Orifice Fitting And Filter7. Prepare the new solenoid valve for installation by installing a new orifice fitting and filter.
The orifice fitting has left-hand threads.
8. Attach the new solenoid valve and reset switch bracket to the vehicle. Tighten top two bolts (5) and leave lower two bolts (4) loose.
Gasket Filter9. Install a new gasket filter into the inlet of the solenoid valve.10. Install the same ether cylinder. See within Ether Cylinder Replacement. Hand tighten the ether cylinder to the solenoid valve. 11. Adjust the reset switch bracket such that reset switch button (6) depresses as much as possible while contacting the ether cylinder. Tighten lower two bolts (4) which fasten the reset switch bracket and solenoid valve to the vehicle. The reset switch must be adjusted correctly in order for the ether injection system to operate properly. The function of the reset switch is: to be OPEN (depressed switch button) when an ether cylinder is installed, and to be CLOSED (extended switch button) when the ether cylinder is removed. Ether injection is disabled when an ether cylinder is removed (reset switch closed).12. Verify that the reset switch is OPEN by continuity checking between the pin and socket in harness plug (7) of the reset switch. There should be no continuity.13. Reconnect the harnesses to the solenoid valve and the reset switch. Turn the disconnect switch to the ON position.Ether Cylinder Removal
Non-Empty Cylinders
During maintenance or servicing, the ether cylinders may need to be removed when they are not empty (for example, the cylinders may have to be removed to gain access to some other item requiring service). Under these conditions, it is desirable to remove and reinstall the ether cylinders without disturbing the "ether cylinder timers" within the ether injection control. This procedure allows the same ether cylinder to be reinstalled after it has been removed. Normal ether cylinder replacement is performed when the ether cylinder is empty. Normal removal of an empty ether cylinder resets the "ether cylinder timers" within the ether injection control. See Ether Cylinder Replacement. Failure to

Have questions with 106673-3300?





Group cross 106673-3300 ZEXEL

Hino 

106673-3300  
9 400 617 300 
220205930A 
INJECTION-PUMP ASSEMBLY
EK130
9 400 617 301 
220205950A 
INJECTION-PUMP ASSEMBLY
K13D-T
9 400 617 302 
220205960A 
INJECTION-PUMP ASSEMBLY
K13C-T
 
 
INJECTION-PUMP ASSEMBLY

Hino 

 
220205880A 
INJECTION-PUMP ASSEMBLY
K13D-T
9 400 612 123 
220205881A 
INJECTION-PUMP ASSEMBLY
K13D-T
 
220206120A 
INJECTION-PUMP ASSEMBLY
P09C-T
9 400 617 303 
220206121A 
INJECTION-PUMP ASSEMBLY
P09C-T
F 019 Z20 119 
220206121B 
INJECTION-PUMP ASSEMBLY
P09C-T
9 400 617 304 
220206140A 
INJECTION-PUMP ASSEMBLY
K13C-T
9 400 617 305 
220206200A 
INJECTION-PUMP ASSEMBLY
K13D-T
9 400 617 306 
220206220A 
INJECTION-PUMP ASSEMBLY
K13D-T
 
220801850A 
INJECTION-PUMP ASSEMBLY
K13C-TK
9 400 617 307 
220801851A 
INJECTION-PUMP ASSEMBLY
K13C-TK
9 400 619 420 
220206480A 
INJECTION-PUMP ASSEMBLY
K13C-TI
Back to top