Information injection-pump assembly
BOSCH
9 400 610 187
9400610187
ZEXEL
106672-4572
1066724572
KOMATSU
6128711035
6128711035

Rating:
Service parts 106672-4572 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
6127-11-3104
12.
Open Pre:MPa(Kqf/cm2)
21.6{220}
15.
NOZZLE SET
Include in #1:
106672-4572
as INJECTION-PUMP ASSEMBLY
Cross reference number
Zexel num
Bosch num
Firm num
Name
9 400 610 187
6128711035 KOMATSU
INJECTION-PUMP ASSEMBLY
SA6D155 K 14CA INJECTION PUMP ASSY PE6P,6PD PE
SA6D155 K 14CA INJECTION PUMP ASSY PE6P,6PD PE
Information:
6N9294 Alternator Group, 3T6352 Alternator 24V 35A (Delco-Remy Number 1117647)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 35A(1) Torque for the ground terminal nut ... 2.3 0.6 N m (21 5 lb in)(2) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(3) Torque for the output terminal nut ... 7.1 0.9 N m (64 8 lb in)3T6354 Regulator (Delco-Remy Number 1116405) Inside Alternator
Voltage setting ... No adjustmentPermissible voltage range ... 26 to 30VDelco-Remy (25SI)
5S9088 Alternator Group, 3T1888 Alternator 24V 50A (Delco-Remy Number 1117248)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output (hot) ... 50A(1) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (10 1 lb ft)7N129 Regulator (Delco-Remy Number 1892824) Inside Alternator
Voltage setting range ... 27.5 1.0VAdjust voltage setting to ... 28V There are two types of adjustment: One type of adjustment is made by removing a pipe plug and turning the adjusting screw one or two notches in a clockwise direction to increase the voltage setting or one or two notches in a counterclockwise direction to decrease the voltage setting. The second type of adjustment is similar except, remove the end cover to expose the potentiometer for adjustment.Then increase speed to get a maximum output of ... 50ABosch
6N9294 Alternator Group, 7N9720 Alternator 24V 35A (Bosch Number 0-122-469-001)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 37ATorque for the ground terminal nut ... 2.1 to 2.8 N m (19 to 25 lb in)(1) Torque for the pulley nut ... 95 to 110 N m (70 to 80 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (10 1 lb ft)9G7567 Regulator (Bosch Number 1-197-011-000) Under Alternator Cover. For
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 35A(1) Torque for the ground terminal nut ... 2.3 0.6 N m (21 5 lb in)(2) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(3) Torque for the output terminal nut ... 7.1 0.9 N m (64 8 lb in)3T6354 Regulator (Delco-Remy Number 1116405) Inside Alternator
Voltage setting ... No adjustmentPermissible voltage range ... 26 to 30VDelco-Remy (25SI)
5S9088 Alternator Group, 3T1888 Alternator 24V 50A (Delco-Remy Number 1117248)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output (hot) ... 50A(1) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (10 1 lb ft)7N129 Regulator (Delco-Remy Number 1892824) Inside Alternator
Voltage setting range ... 27.5 1.0VAdjust voltage setting to ... 28V There are two types of adjustment: One type of adjustment is made by removing a pipe plug and turning the adjusting screw one or two notches in a clockwise direction to increase the voltage setting or one or two notches in a counterclockwise direction to decrease the voltage setting. The second type of adjustment is similar except, remove the end cover to expose the potentiometer for adjustment.Then increase speed to get a maximum output of ... 50ABosch
6N9294 Alternator Group, 7N9720 Alternator 24V 35A (Bosch Number 0-122-469-001)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (hot) ... 37ATorque for the ground terminal nut ... 2.1 to 2.8 N m (19 to 25 lb in)(1) Torque for the pulley nut ... 95 to 110 N m (70 to 80 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (10 1 lb ft)9G7567 Regulator (Bosch Number 1-197-011-000) Under Alternator Cover. For