106671-8721 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1066718721 220008561a


 

Information injection-pump assembly

ZEXEL 106671-8721 1066718721
HINO 220008561A 220008561a
106671-8721 INJECTION-PUMP ASSEMBLY
Rating:
9
Buy INJECTION-PUMP ASSEMBLY 106671-8721 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-8721 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106067-0270
3. GOVERNOR 105489-4781
4. SUPPLY PUMP 105207-1500
5. AUTOM. ADVANCE MECHANIS 105635-0410
6. COUPLING PLATE 105663-0540
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5031
11. Nozzle and Holder 23600-1221A
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105031-5300
14. NOZZLE 105015-4640
15. NOZZLE SET

Include in #1:

106671-8721 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106671-8721 
106671-8722 
 
220008561A  HINO
INJECTION-PUMP ASSEMBLY
K13U * K 14CA PE6P,6PD PE




Information:

Additional Parts Needed for Installation
Fluid Property Sensor Mounting Bracket
A mounting bracket must be fabricated to support the Fluid Property Sensor. Since the kit can be used on a large range of engines in both stationary and machine applications, no universal mounting bracket design is possible. A bracket must be field fabricated to allow mounting of the sensor to a structural component of the machine. Leave room for electrical connection and room at each end for Engine Lubricating Oil line connections.Fittings and Adapters
Due to the large range of engines that this system may be used on, a list of all Engine Lubrication Oil line fittings, sizes, styles, and adapters are not possible. As a starting point, the inlet and outlet of the sensor adapter is a 37 degree Flare for 1" oil lines. This must be adapted to the correct size oil line tubing required for each engine. It is likely that the supply and return fuel lines will be of different sizes. It is recommended that the oil line tubing be new and in good condition. The tubing MUST be clean inside. Any small particles that are carried from the inlet hose through the transducer from the system and dislodge the particles. If hoses are equipped with O-ring fittings, the O-rings must be new.Wiring Diagram
Note: During Installation, it is important to protect wiring in key locations. Key locations are any area where the wiring could be nicked or cut and come in contact with the chassis. Avoid installation practices where there could be excessive flexing, chafing, or cutting of the wiring.
Illustration 1 g06137996
Fluid Property Sensor Wiring Schematic
Installation
Machine Preparation
Move the machine to a smooth, level location, and away from other working machines and personnel.
Lower the implements to the ground.
Stop the engine.
Engage the parking brake for the machine.
Place the disconnect switch in the OFF position.
Follow all LOTO instructions for the machine.Installation of the Fluid Property Sensor
The Fluid Property Sensor must be located on a field fabricated bracket in a location of the installer's choice. When selecting a mounting location, the installer must mount the sensor in an area off the engine to reduce vibration of the sensor as well as accessibility of sensor and electrical connection. Electrical connections should avoid sharp bends at connectors, sharp edges, and chafing surfaces. Harnesses should be supported at no less than 30.48 cm (12 inch) intervals. The Fluid Property Sensor must be installed with the orifice opening in the upright position as shown in Illustration 2.
Illustration 2 g06138010
Fluid Property Sensor Installation
(A) Oil Pump
(B) Oil Filter
(C) Engine Oil Gallery
(D) Isolation Valve
(E) Oil Flow
(F) Fluid Property Sensor Orientation
(G) Oil Reservoir
(H) Oil Strainer
(I) Engine Oil SumpInstallation of the Electrical Harnesses
Note: During installation, it is important to protect wiring in key locations. Key locations are any area where the wiring could be nicked or cut and come in contact with the chassis. Avoid installation practices where there could be excessive flexing, chafing, or cutting of the wiring.
Install the 514-3811 Instl GP-Field (Fluid Property Harness) on Fluid Property Sensor.
Route harness back

Have questions with 106671-8721?





Group cross 106671-8721 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY

Hino 

 
S220204320A 
INJECTION-PUMP ASSEMBLY
9 400 610 888 
220204320A 
INJECTION-PUMP ASSEMBLY
K13C-T
 
220008330A 
INJECTION-PUMP ASSEMBLY
K-4
9 400 619 768 
220008330B 
INJECTION-PUMP ASSEMBLY
K-4
9 400 610 889 
220008331A 
INJECTION-PUMP ASSEMBLY
K-4
9 400 617 015 
220008331B 
INJECTION-PUMP ASSEMBLY
K-4
 
220008560A 
INJECTION-PUMP ASSEMBLY
K13U
106671-8721  

106671-8722 
 
220008561A 
INJECTION-PUMP ASSEMBLY
K13U
9 400 617 016 
220008562A 
INJECTION-PUMP ASSEMBLY
K13U
 
220801650A 
INJECTION-PUMP ASSEMBLY
K-4
 
220801650B 
INJECTION-PUMP ASSEMBLY
K-4
9 400 617 017 
220801651A 
INJECTION-PUMP ASSEMBLY
K-4
F 019 Z10 415 
220204470A 
INJECTION-PUMP ASSEMBLY
P09B-TB
F 019 Z10 416 
220204471A 
INJECTION-PUMP ASSEMBLY
P09B-TB
F 019 Z10 417 
220204472A 
INJECTION-PUMP ASSEMBLY
P09B-TB
F 01G 09U 07X 
220204472B 
INJECTION-PUMP ASSEMBLY
P09B-TB
F 019 Z10 243 
220204473A 
INJECTION-PUMP ASSEMBLY
P09B-TB
9 400 610 890 
220204474A 
INJECTION-PUMP ASSEMBLY
P09B-TB
 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 617 018 
220008830A 
INJECTION-PUMP ASSEMBLY
K13D
 
220008910A 
INJECTION-PUMP ASSEMBLY
K13D
9 400 610 891 
220008911A 
INJECTION-PUMP ASSEMBLY
K13D
9 400 611 901 
220008911B 
INJECTION-PUMP ASSEMBLY
K13D
 
220204560A 
INJECTION-PUMP ASSEMBLY
K13C-T
9 400 610 892 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 610 892 
S220204561A 
INJECTION-PUMP ASSEMBLY
9 400 612 077 
220204561A 
INJECTION-PUMP ASSEMBLY
K13C-T
 
220801681A 
INJECTION-PUMP ASSEMBLY
K13D
 
220801682A 
INJECTION-PUMP ASSEMBLY
K13D
9 400 617 019 
220801682B 
INJECTION-PUMP ASSEMBLY
K13D
 
220204640A 
INJECTION-PUMP ASSEMBLY
K13C-T
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
9 400 610 893 
 
INJECTION-PUMP ASSEMBLY
K13C-T

Hino 

9 400 613 232 
220204641A 
INJECTION-PUMP ASSEMBLY
K13C-T