106671-8661 ZEXEL 9 400 611 900 BOSCH INJECTION-PUMP ASSEMBLY 9400611900 1066718661


 

Information injection-pump assembly

BOSCH 9 400 611 900 9400611900
ZEXEL 106671-8661 1066718661
106671-8661 INJECTION-PUMP ASSEMBLY
Rating:
13
Buy INJECTION-PUMP ASSEMBLY 106671-8661 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-8661 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106061-7720
3. GOVERNOR 105407-5341
4. SUPPLY PUMP 105217-1680
5. AUTOM. ADVANCE MECHANIS 105635-0350
6. COUPLING PLATE 105663-0540
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-5721
11. Nozzle and Holder 23600-1970B
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105031-5470
14. NOZZLE 105015-7020
15. NOZZLE SET

Include in #1:

106671-8661 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106671-8661 
106671-8662 
9 400 611 900 
   
INJECTION-PUMP ASSEMBLY
* K 14CA PE6P,6PD PE




Information:

Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
Caterpillar has discovered that when certain products equipped with the Caterpillar Regeneration System (CRS) are left idling for extended periods of time (greater than 1 hr) and ambient temps are lower than −15° C (5° F), certain conditions may be met which will disable the ability to regenerate the DPF. If the regeneration system cannot activate, the DPF will accumulate too much soot and must eventually be replaced.The issues Caterpillar has identified in extreme cold ambient conditions are the coolant temperature may become too cold for the regeneration system to activate. Also, the pressure lines which connect the DPF inlet section to the DPF intake pressure sensor may collect condensation and freeze. This freezing causes an E1154 (2) or 3609-18 Low DPF #1 Intake Pressure event code. The event code will disable the regeneration until the fault condition goes away.If you suspect low coolant temperature may be contributing to an inability to regenerate the DPF, review the product status report. The product status report is used for investigating the following fault code trend. If coolant temp is the only issue, you will likely see a combination of the following fault codes:
E995 (2) High DPF #1 Soot Loading or 3719-16 Particulate Trap #1 Soot Load Percent : High - moderate severity (2)
Indicates DPF soot load percent has reached 100 percent
E995(3) High DPF #1 soot loading or 3719-0 Particulate Trap #1 Soot Load Percent : High - most severe (3)
Indicates DPF soot load percent has reached 116 percent
E992(3) DPF Active Regeneration Inhibited Due to Temporary System Lockout or 3714-31 Particulate Trap Active Regeneration Inhibited Due to Temporary System Lockout
Indicates DPF soot load reached 116 percent and 10 minutes has passed since that point. Ability to perform automatic or manual regenerations is disabled. Caterpillar Electronic Technician (ET) regeneration is only type of regeneration allowed.
E991 (3) DPF Active Regeneration Inhibited Due to Permanent System Lockout or 3715-31 Particulate Trap Active Regeneration Inhibited Due to Permanent System Lockout
Indicates DPF soot load percent has reached 140 percent. All types of regeneration are disabled. DPF must be replaced as the amount of soot load will damage the DPF if ignited by regeneration process.If you suspect the pressure line for the DPF intake pressure has frozen, you will see a combination of fault codes. These codes will consist of the codes listed above with the addition of the following codes: E1154 (2) DPF #1 intake pressure low and 3609-18 DPF #1 Intake Pressure : Low - moderate severity (2).Solution
Caterpillar recommends the following when extended idling is likely to occur and ambient temperatures are less than −15° C (5° F):
Turn off machine before the end of shift. Before shutting down, perform a manual DPF regeneration and reduce soot load to 0 percent. The soot load must be above the 15 percent threshold needed to activate a manual DPF regeneration.If extended idling is

Have questions with 106671-8661?





Group cross 106671-8661 ZEXEL

Hino 

 
220204110A 
INJECTION-PUMP ASSEMBLY
K13C-T
 
S220204110A 
INJECTION-PUMP ASSEMBLY
K13C-T
9 400 610 887 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 610 887 
S220204111A 
INJECTION-PUMP ASSEMBLY
9 400 617 006 
220204111A 
INJECTION-PUMP ASSEMBLY
K13C-T
 
220008110A 
INJECTION-PUMP ASSEMBLY
K13C
9 400 617 007 
220008200A 
INJECTION-PUMP ASSEMBLY
K13C
F 019 Z10 407 
220008120A 
INJECTION-PUMP ASSEMBLY
K13D
F 019 Z10 408 
220008120B 
INJECTION-PUMP ASSEMBLY
K13D
F 019 Z10 409 
220008120C 
INJECTION-PUMP ASSEMBLY
K13D
F 019 Z10 410 
220008121A 
INJECTION-PUMP ASSEMBLY
K13D
9 400 617 008 
220008130A 
INJECTION-PUMP ASSEMBLY
K13C
F 019 Z10 411 
220204080A 
INJECTION-PUMP ASSEMBLY
K13C-T
F 019 Z10 412 
 
INJECTION-PUMP ASSEMBLY

Hino 

F 019 Z10 412 
S220204081A 
INJECTION-PUMP ASSEMBLY
9 400 617 009 
220204081A 
INJECTION-PUMP ASSEMBLY
K13C-T
 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 617 010 
220204180A 
INJECTION-PUMP ASSEMBLY
EK100
 
220204280A 
INJECTION-PUMP ASSEMBLY
K13C-T
 
S220204280A 
INJECTION-PUMP ASSEMBLY
K13C-T
106671-8661  

106671-8662 
9 400 611 900 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 617 011 
220204281A 
INJECTION-PUMP ASSEMBLY
K13C-T
9 400 617 012 
220204360A 
INJECTION-PUMP ASSEMBLY
EK100
F 019 Z10 413 
220204420A 
INJECTION-PUMP ASSEMBLY
P09B-TI
F 019 Z10 414 
220204421A 
INJECTION-PUMP ASSEMBLY
P09B-TI
F 019 Z10 087 
220204421B 
INJECTION-PUMP ASSEMBLY
P09B-TI
9 400 617 013 
220204422A 
INJECTION-PUMP ASSEMBLY
P09B-TI
9 400 617 014 
220008430A 
INJECTION-PUMP ASSEMBLY
EK100
Back to top