106671-8134 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1066718134 220203165a


 

Information injection-pump assembly

ZEXEL 106671-8134 1066718134
HINO 220203165A 220203165a
106671-8134 INJECTION-PUMP ASSEMBLY
Rating:
40
Buy INJECTION-PUMP ASSEMBLY 106671-8134 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-8134 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106061-5750
3. GOVERNOR 105407-4022
4. SUPPLY PUMP 105217-1680
5. AUTOM. ADVANCE MECHANIS 105681-0380
6. COUPLING PLATE 105663-0560
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5273
11. Nozzle and Holder 23600-1561C
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105031-4451
14. NOZZLE 105015-4920
15. NOZZLE SET

Include in #1:

106671-8134 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106671-8134 
106671-8135 
 
220203165A  HINO
INJECTION-PUMP ASSEMBLY
P09B-TI * K




Information:

Events
The events are used in order to record a problem that is detected by the control system. Events are also used to document adverse engine operation. Events will be communicated to the service tool via the CDL. An event indicates that the control system has detected an engine problem. An event does not indicate an electronic problem. For example, the high exhaust temperature event is disabled if a problem with the temperature sensor is detected. (Events can be configured to be triggered on a diagnostic.)An event is identified by a numerical code. The EID (Event Identifier) identifies an engine problem or a problem with the machine. The service tool is used to display the EID. The service tool adds descriptive text for each EID in order to avoid mistakes in interpreting the codes.Logged Events
When an event is activated, information about the event is logged into permanent memory for the Electronic Control Module. The CDL can then request this information from the ECM. The CDL will display the following information for each logged event. Up to twenty five different events can be logged. Events are not automatically erased.
EID
FMI
Description of the event
Number of occurrences
The first time of occurrence
The last time of occurrenceEvents may be cleared from the memory of the ECM in order to use the CDL. Logged events can be configured so that a factory password is required to clear the event. Table 1 references the Event Codes that can be seen in order to use the Diesel Particulate Filter Monitor System.
Table 1
EID     Description     Security Level    
194     Warning for the High Exhaust Temperature     1    
194     Critical Warning for the High Exhaust Temperature     2    
1049     Warning for the Pressure Inlet for the High Particulate Trap     1    
1049     Critical Warning for the Pressure Inlet for the High Particulate Trap     2    

Have questions with 106671-8134?





Group cross 106671-8134 ZEXEL

Hino 

 
220203161A 
INJECTION-PUMP ASSEMBLY
P09BTI
 
220203162A 
INJECTION-PUMP ASSEMBLY
P09B-TI
 
220203163A 
INJECTION-PUMP ASSEMBLY
P09B-TI
 
220203164A 
INJECTION-PUMP ASSEMBLY
P09B-TI
106671-8134  

106671-8135 
 
220203165A 
INJECTION-PUMP ASSEMBLY
P09B-TI
 
220203166A 
INJECTION-PUMP ASSEMBLY
P09B-TI
9 400 610 883 
220203166B 
INJECTION-PUMP ASSEMBLY
P09B-TI
Back to top