106671-8110 ZEXEL 9 400 616 975 BOSCH INJECTION-PUMP ASSEMBLY 9400616975 1066718110 220006000a


 

Information injection-pump assembly

BOSCH 9 400 616 975 9400616975
ZEXEL 106671-8110 1066718110
HINO 220006000A 220006000a
106671-8110 INJECTION-PUMP ASSEMBLY
Rating:
33
Buy INJECTION-PUMP ASSEMBLY 106671-8110 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-8110 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106060-5840
3. GOVERNOR 105489-1270
4. SUPPLY PUMP 105217-1301
5. AUTOM. ADVANCE MECHANIS 105635-0170
6. COUPLING PLATE 105662-0850
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5031
11. Nozzle and Holder 236001221C
12. Open Pre:MPa(Kqf/cm2) 21.6(220)
13. NOZZLE-HOLDER 105031-5300
14. NOZZLE 105015-4640
15. NOZZLE SET

Include in #1:

106671-8110 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106671-8110 
9 400 616 975 
220006000A  HINO
INJECTION-PUMP ASSEMBLY
EK100 * K




Information:


Table 1
Service Tools    
Part Number    Part    
    Caterpillar Electronic Technician (ET)    
6V-7070
9U-7330     Digital Multimeter    
8T-3224     Needle Tip Group    
7X-1710     Multimeter Probe Group    
8T-8726     Adapter Cable Assembly    
9U-7246     Connector Repair Kit
DT    
4C-3406     Connector Repair Kit    
4C-8195     Control Service Tool (Switch Box)    
Illustration 1 g00774942
Connections for the Communication Adapter II and the Caterpillar Electronic Technician (ET)The components that are needed in order to use the Communication Adapter II and the Caterpillar Electronic Technician ( ET) in order to determine diagnostic codes are listed: (6) Cable (7) 171-4400 Communication Adapter II (8) Service diagnostic cable. (9) Current version of Cat ET software and an IBM-COMPATIBLE personal computerReferenceSee Special Publication, NEHS0758, "Communications Adapter II User's Manual Contains Software".Note: Caterpillar Electronic Technician (ET) is a software program that can be used on an IBM compatible personal computer. In order to use the Cat ET, order the following materials: Special Publication, JERD2124, "ET Single Use Program License", Special Publication, JEHP1026, "Information and Requirements Sheet", 7X-1425 Data Link Cable and the Data Subscription and Special Publication, JERD2142, "Data Subscription". The Special Publication, JEHP1026, "Information and Requirements Sheet" lists the required hardware and the features of the Cat ET.The Cat ET is not required in order to determine the diagnostic codes and the Cat ET is not required in order to clear the diagnostic codes. However, the process of determining the diagnostic codes is easier and faster by using the Cat ET. The Cat ET can also display information on the history of a diagnostic code and the parameter status of diagnostic codes. These features allow the Cat ET to be a useful tool for troubleshooting.The Cat ET is used to communicate to the electronic control module over the data link by connecting to the machine diagnostic connector. For more information and the locations of the connectors, see Troubleshooting, "Electrical Components and Connector Locations" and the Electrical System Schematic in your machine's Service Manual.For instructions on servicing Sure Seal connectors, see Special Instruction, SMHS7531. For instructions on servicing Deutsch connectors, see Special Instruction, SEHS9615.Use the digital multimeter for measuring resistance or for measuring voltage. For instructions about the use of the 6V-7070 Digital Multimeter, see Special Instruction, SEHS7734. The 7X-1710 Multimeter Probe measures the voltage at the connectors without disconnecting the connectors. The probe cables are pushed into the back of the connector along the wire. The 8T-8726 Adapter Cable has a breakout with 3 pins. The adapter cable is used for measurements in the sensor circuits.Note: Except for harness tests, using continuity testers such as the 8T-0500 Continuity Tester or voltage testers such as the 5P-7277 Voltage Tester is not recommended for today's Caterpillar electrical circuits.

Have questions with 106671-8110?





Group cross 106671-8110 ZEXEL

Hino 

9 400 616 974 
220005980A 
INJECTION-PUMP ASSEMBLY
EK100
106671-8110  
9 400 616 975 
220006000A 
INJECTION-PUMP ASSEMBLY
EK100
 
220005990A 
INJECTION-PUMP ASSEMBLY
EK100
 
220203161A 
INJECTION-PUMP ASSEMBLY
P09BTI
 
220203162A 
INJECTION-PUMP ASSEMBLY
P09B-TI
 
220203163A 
INJECTION-PUMP ASSEMBLY
P09B-TI
 
220203164A 
INJECTION-PUMP ASSEMBLY
P09B-TI
 
220203165A 
INJECTION-PUMP ASSEMBLY
P09B-TI
 
220203166A 
INJECTION-PUMP ASSEMBLY
P09B-TI
9 400 610 883 
220203166B 
INJECTION-PUMP ASSEMBLY
P09B-TI
 
220006060A 
INJECTION-PUMP ASSEMBLY
EK100
 
220006061A 
INJECTION-PUMP ASSEMBLY
EK100
 
220006063A 
INJECTION-PUMP ASSEMBLY
EK100
 
220006063B 
INJECTION-PUMP ASSEMBLY
EK100
 
220006063C 
INJECTION-PUMP ASSEMBLY
EK100
9 400 616 976 
220006064B 
INJECTION-PUMP ASSEMBLY
EK100
9 400 612 076 
220006090A 
INJECTION-PUMP ASSEMBLY
EK100
9 400 616 977 
220006100A 
INJECTION-PUMP ASSEMBLY
EK100
9 400 616 978 
 
INJECTION-PUMP ASSEMBLY
P09B-TI
 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 616 979 
220203330A 
INJECTION-PUMP ASSEMBLY
EP100-T
9 400 616 980 
220203310A 
INJECTION-PUMP ASSEMBLY
EK100
9 400 616 980 
S220203310 
INJECTION-PUMP ASSEMBLY
EK100
9 400 616 980 
S220203310A 
INJECTION-PUMP ASSEMBLY
EK100
Back to top